5 of 24
ISSUED: 11-09-07 SHEET #: 202-9252-1
Visit Peerless website at www.peerlessmounts.com
For customer care call 1-800-729-0307 or 708-865-8870
Installation to Solid Concrete or Cinder Block
1
Make sure that wall plate (
AA
) is level, use it as a
template to mark four mounting holes. The top mounting
hole should be 4.6" (117 mm) above the desired screen
center as shown in figure 1.1 on page 4. Drill four 1/4"
(6 mm) dia. holes to a minimum depth of 2.5" (65 mm).
Insert anchors (
DD
) in holes flush with wall as shown
(right). Place wall plate over anchors and secure with
#14 x 2.5" screws (
CC
). Level, then tighten all fasteners.
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications.
It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid
breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
WARNING
concrete
surface
1
3
2
DD
Drill holes and insert anchors (
DD
).
Place plate (
AA
)
over anchors (
DD
) and secure with screws (
CC
).
Tighten all fasteners.
AA
DD
CC
CUT
A
W
A
Y
VIEW
INCORRECT
CORRECT
wall plate
plaster/
dry wall
concrete
wall plate
concrete
plaster/
dry wall
• Always attach concrete anchors directly to load-
bearing concrete.
• Never attach concrete anchors to concrete covered
with plaster, drywall, or other finishing material. If
mounting to concrete surfaces covered with a finishing
surface is unavoidable, the finishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when tighten-
ing screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
CC
AA
DD
solid concrete
cinder block