background image

 

6

  5.1 Mounting pump stations and accessories onto VEGA 390

SCOPE OF SUPPLY:

Vega 390 Thermal Store, code 12968 (the other one, code 12967, differs only in the number 
of heating circuits):

Code Name Qty

12104 HSK 390 V Thermal Store, no insul., 1 stainless steel DHW coil

1 pcs

12036 Insulation for HSK390 V Thermal Store - NEODUL - code 12104

1 pcs

12224 Pump Station for Thermal Store - 2 circuits

1 pcs

12690 Angled Ball Valve Assy for LYRA

1 pcs

13494 1” Elbow Assy out to HP, for VEGA 390

1 pcs

13476 Zone Valve Assy in from HP, for VEGA 390

1 pcs

13477 Zone Valve Assy out to HP, for VEGA 390

1 pcs

13478 1” Elbow Assy in from HP, for VEGA 390

1 pcs

13479 1” Elbow Assy in from h. circuit, for VEGA 390

1 pcs

13497 1” Valve Assy out to h. circuit, for VEGA 390

1 pcs

13529 Safety & Drain Valve Assy for VEGA 390

1 pcs

13237 Accessory Kit for LYRA and VEGA 

1 pcs

6230 Flange for PS2F tank, d=312, no holes

1 pcs

13485 Kit for connection of assys onto VEGA 390

1 pcs

154 Sheath 7x8-100, 1 sensor, 1/2"

3 pcs

10845 Capillary spring, small, 1/2", stainless steel

3 pcs

12714 Cover for 2-circuit pump station, for 380l Thermal Store

1 pcs

12223 Front insulation for cover for 2-circuit pump station

1 pcs

12721 Top insulation for 2-circuit pump station, 380l

1 pcs

12713 Black knurled screw, M6x1-10 PA 6.6

4 pcs

Code Name

        Qty

6969 1" hex nipple, MM, thick wall

1 pcs

13481 DN 20 pipe (1" nut) l=1010 mm

1 pcs

13489 DN 20 pipe (1" nut) l=690 mm

1 pcs

13488 DN 25 pipe (5/4" nut) l=490 mm

1 pcs

13484 DN 25 pipe (5/4" nut) l=125 mm

1 pcs

7187 Insulation DNa 35, 13 mm thick (2 m)

1 m

6447 Insulation DNa 28, 13 mm thick (2 m)

2 m

12996 M6x16 stainless steel bolt (hex socket) DIN 912/A2

4 pcs

7853 6.5 washer (large diameter 3d)

8 pcs

9980 1" nut gasket - 18,5x30x2 PTFE

4 pcs

9981 5/4" nut gasket - 25x39x2 PTFE

4 pcs

Code Name Qty

11969 6/4" FF ball valve

1 pcs

7627 6/4“ Hex nipple, MM, thick wall

2 pcs

8757 6/4" T-piece in brass,   FFF

1 pcs

8766 Reducing hex nipple 1"x6/4" MM

1 pcs

7049 1" T-piece in brass,   FFF

1 pcs

6969 1" Hex nipple, MM, thick wall

1 pcs

7701 Reducing hex nipple, 1“x1/2“, MM, brass

1 pcs

11713 1/2“ drain valve, no handle, with cap

1 pcs

9097 Plug 1/2“ + gasket, brass

1 pcs

12968 - VEGA 390 2 circ.

13485 - Assemblies Connection Kit for VEGA 390

13437 - Expansion Vessel Connection Kit

Содержание VEGA 390

Страница 1: ...VEGA 390 THERMAL STORE with stainless steel DHW coil EN v 1 3 Installation and Operation Instructions...

Страница 2: ...5 5 1 Mounting pump stations and accessories onto VEGA 390 6 5 2 Connecting heating circuits 17 5 3 Connecting a solar circuit 17 6 Installation and Commissioning 18 6 1 Connecting heat sources 18 6...

Страница 3: ...tly on the tank the second main layer features thermal conductivity l 0 032 W m K the third layer is a hard glossy washable surface The total insulation thickness is 100 mm 1 4 Connection points 1 top...

Страница 4: ...changer volume 23 l DHW heat exchanger surface area 6 sqm Max working temperature in tank 95 C Max working temperature in DHW heat exchanger 95 C Max working pressure in tank 4 bar Max working pressur...

Страница 5: ...he tank The heat exchanger connects to a cold water inlet with a G1 nipple and to DHW with the other one As soon as hot water is drawn from an outlet cold water flows into the immersed heat ex changer...

Страница 6: ...1 2 stainless steel 3 pcs 12714 Cover for 2 circuit pump station for 380l Thermal Store 1 pcs 12223 Front insulation for cover for 2 circuit pump station 1 pcs 12721 Top insulation for 2 circuit pump...

Страница 7: ...ealant or with the gaskets included in separate kits 1 Remove the tank from its pallet and place it to its approximate position shift the bottom insulation under the tank 2 Slide the insulation insert...

Страница 8: ...76 Remove the zone valve actuator from the assembly prior to mounting Port A of the zone valve shall be oriented upwards 6 Loosen the clamps fit the metal sheet against the four pins code 12710 from K...

Страница 9: ...690 8 Fit the pump station with 4 way mixing valves code 12224 or 12225 Join it with the earlier fitted Angled Ball Valve Assy and tighten the clamps 9 Fit 1 Valve Assy out to h circuit code 13479 and...

Страница 10: ...Assy out to h circuit code 13497 11 Fit the Safety Drain Valve Assy code 13529 into the sleeve 12 Fit the sheaths code 154 into the dedicated sleeves and plug 1 2 with gasket code 9097 Plug 1 2 code...

Страница 11: ...11 13 Fit the Zone Valve Assy out to HP code 13477 Remove the zone valve actuator prior to fitting Port A of the zone valve shall be oriented upwards 14 Fit the 1 Elbow Assy out to HP code 13494...

Страница 12: ...12 15 Fit the thermometer code 10474 from the Kit 13237 16 Fit the 1 Elbow Assy in from HP code 13478...

Страница 13: ...sulation circa 550 mm long 1 tube 5 4 DN 25 125 mm long code 13484 insulation circa 200 mm long 18 Locate the Zone Valve Assy fitted as shown in point 13 and the Elbow Assy fitted as shown in point 14...

Страница 14: ...fitted as shown in point 11 Connect these two using the dedicated 1 pipe 690 mm long code 13489 21 Locate the 1 hex nipple in the Zone Valve Assy fitted as shown in point 13 and the 1 Elbow Assy fitte...

Страница 15: ...code 6971 all included in Kit 13237 23 Push the front insulation onto the pump station with 4 way valves 24 Connect the terminals of the pumps push the cables behind the insulation 25 Fit the plastic...

Страница 16: ...16 Completely fitted tank Safety high limit thermostat for electric heating elements optional part...

Страница 17: ...o connected to a solar thermal system An extra flange and a tube heat exchanger coil will be needed depending on the output of the solar thermal system All connecting pipes between the tank and solar...

Страница 18: ...ating elements shall be installed together with a safety temperature limiter An el heating element shall be wired by qualified staff only 6 4 Connecting sanitary water piping DHW piping shall be done...

Страница 19: ...Installation Manual was not respected the product was used for other purposes than intended Warranty does not cover usual wear and tear damage caused by fire water electricity or a natural disaster de...

Страница 20: ...04 2016 REGULUS spol s r o Do Kout 1897 3 http www regulus eu 143 00 Praha 4 E mail sales regulus eu CZECH REPUBLIC...

Отзывы: