Regulus TP 07-01 Скачать руководство пользователя страница 4

4

Thermostat commissioning and programming:

• Open the bottom compartment door and insert batteries. Mind the right polarity.
• Press open the door on the right side.
• Slide the mode selector to the 

„heat“

 position.

• 

Setting the time:

 Select either 12- or 24-hour display mode by pressing 

12/24 HOURS

 pushbutton (4).

• Set the hour by pressing the 

HOUR

 button (1) and minute by MIN button (2). To save the setting, either wait for 

  10 sec or press 

RUN

 (10).

• 

Setting the day:

 Select the desired day by pressing 

DAY

 (3). 

• 

Setting a program:

 The thermostat has a factory-preset program (see chart 1), identical for every weekday. This 

preset program can be restored by pressing 

AUTO PROG

 (5). The thermostat switches the heating on and off in 

advance with respect to the room character in order to reach the desired temperature at the set time. This function can 
be switched off by a DIP switch on the PCB (see pic.). 

program No.

1

2

3

4

time

6:00

8:00

16:00

22:00

temperature (°C)

20

16

20

16

• The preset program can be changed as follows:
• Select the desired day or a block of days (Mo-Fr or Sa-Su) by pressing 

PROG DAY

 button (7).

• Then press 

PROG

 (6), program number 1 is displayed.

• Set the desired time span by pressing 

HOUR

 (1) and 

MIN

 (2) buttons, and the desired temperature by the respective 

buttons with arrows.

• Then press 

PROG

 (6), program number 2 is displayed and at the same time program No. 1 is saved. If desired, 

continue programming time sections 

2-4

 in the same manner. When 

fi

nished, either wait for 10s or press 

RUN

 (10), the 

thermostat will save the settings and return to normal operation.

Setting the temperature difference: 

• The thermostat is factory set to 0.5 °C temperature difference, i.e. it switches on/off 0.5 °C below/above the set 

temperature. 

• This value can be changed by pressing both 

UP

 and 

DOWN

 arrows for at least 3s. 

SPAN

 is displayed.

• This setting can be increased to 1.5 °C max. by pressing the 

UP

 arrow, decreased by pressing the 

DOWN

 arrow.

• Wait for 10 s or press 

RUN

 (10) to exit setting.

Program viewing:

• The programs set can be viewed. Select the desired day by pressing 

PROG DAY

 (7).

• The time sections 

1-4

 are displayed by pressing the 

PROG

 (6) button. The time of change and the set temperature are 

displayed for each program. Wait for 10 s or press 

RUN

 (10) to exit viewing. 

intelligent heating on

off