A mains socket or circuit breaker shall be located close to the appliance and shall be easily accessible.

Never disconnect the 230 V power supply to PG 600 SX when it is running - the earth protection of both
PG 600 SX and the connected load would be interrupted.

Check that when all loads are connected, the total earth leakage current does not exceed 2.7 mA (EN
62040-1-1).

After PG 600 SX gets connected to the power grid, the battery recharging starts. At this point also the
cooling fan starts. After the battery is fully charged and the inner temperature in PG 600 SX does not
rise any more, the fan will not start again

.

In case of a power supply breakdown, the fan turns on, cooling the inverter if needed.

When power supply is restored, the timer turns on and the cycle is repeated.

3.

OPERATING STATES OF PG 600 SX

Power grid operation 

The input voltage is shown on the screen, the battery is being recharged or is already fully charged. 

Battery operation 

The screen shows no power grid voltage. The symbol of battery operation is shown. PG 600 SX will provide backup 
until either power supply is restored or the battery completely discharged. When the threshold of 24% is reached, the 
battery starts making intermittent alarm sound. From the moment on, the PG 600 SX may turn off any time depending 
on the load level. After the power supply is restored, it takes at least 12 hours (preferably 24) to fully charge the battery. 

Alarm 

The alarm symbol is shown and PG 600 SX makes a sound. When overloaded, PG 600 SX will disconnect the output 
and make a continuous sound. Until the load is disconnected and PG 600 SX turned off and on again, it will not fulfil its 
backup function. The sound alarm will start when the battery level falls to 24%. 

4.

TROUBLESHOOTING

Situation

 

Cause 

Solution

 

The screen is not lit 

PG 600 SX 

is off.

No grid power, discharged battery.

Defect battery

.

Press and hold ON push button,
switching PG 600 SX on

.

Restore power supply and let the battery
recharge. Eventually check the fuse.

Replace the battery

.

The screen is lit but the 
connected load (pump) is not 
running 

 

PG 600 SX 

has been switched off,

disconnecting the load.

Fault

Check battery condition and connection

Contact service staff

Grid voltage is present but PG 
600 SX displays zero grid 
voltage and works in the battery 
mode. 

PG 600 SX gets no grid power.

Electrical socket is defect

Check the circuit breakers/fuses.

Check the el. Socket.

Faulty fuse

Replace the fuse

PG 600 SX 

does not serve 

the expected backup time 

Battery capacity may be reduced: 

Too long storage time

Overload

Battery lifetime over

Repeated frequent power
failures when the battery
does not get fully charged
again

Let the battery charge for about 8 hours

Disconnect excess load

Replace the battery

Sound alarm (signal) 
sounds every 0.5 sec. 

Overload

Check what is connected to PG 600 SX
and disconnect excess load.

Sound alarm (signal) 
sounds continuously and 
then PG 600 SX turns off 

Discharged battery

Restore power supply and let the battery
recharge.

Содержание PG 600 SX

Страница 1: ...www regulus eu Installation and Operation Manual EN PG 600 SX Backup Power Supply PG 600 SX PG 600 SX...

Страница 2: ...ion use features description 5 1 1 General description 5 1 2 Front panel 5 1 3 Rear panel 6 1 4 Acoustic signals 6 2 Installation 7 2 1 Recommended wiring 7 2 2 Turning PG 600 SX on with no grid power...

Страница 3: ...SE RESPECT THE FOLLOWING INSTRUCTIONS The appliance may be installed by authorized staff only When switching off the electric appliance fed by PG 600 SX do not forget to switch off the PG 600 SX itsel...

Страница 4: ...ong time This is quite normal In order to be sure about its proper working test its backup function at least once a year and verify if its backup time is sufficient Should the battery get very hot sta...

Страница 5: ...00 SX may be performed by a user The front panel is designed for manual control do not use sharp or pointed items PG 600 SX is not designed for operation in explosive environment PG 600 SX and the bat...

Страница 6: ...socket OUTPUT 3 Fuse holder w 10 A fuse FUSE 4 Battery cables 1 3 ACOUSTIC SIGNALS Tone Condition Short 0 5 sec PG 600 SX switching on Continuous 2 sec Switching off by pressing OFF button or automati...

Страница 7: ...d At the same time the internal cooling fan also starts running 5 Connect your pump or another load by plugging its cable into the socket of PG 600 SX It is necessary to stick to a TN S wiring system...

Страница 8: ...X will work normally charging the battery 2 3 TURNING PG 600 SX OFF PG 600 SX can be turned off by pressing and holding the OFF push button for at least 3 sec WARNING The battery is not being charged...

Страница 9: ...eferably 24 to fully charge the battery Alarm The alarm symbol is shown and PG 600 SX makes a sound When overloaded PG 600 SX will disconnect the output and make a continuous sound Until the load is d...

Страница 10: ...utput Max inverter power output 300 W Nominal voltage 230 V Voltage range backup mode 230 V 10 Frequency 50 Hz Frequency tolerance backup mode 0 5 Hz Waveform backup mode smooth sine wave Others Dimen...

Отзывы: