Regulus NBC 170 HP Скачать руководство пользователя страница 5

NBC 170 HP - www.regulus.eu

Main Features

Description

Working fluid

Code

Energy efficiency class
Standing loss
Storage volume 

Total tank volume
Fluid volume in tank
Fluid volume in heat exchanger
Heat exchanger surface area
Max. temperature in tank
Max. temperature in heat exchanger
Max. pressure in tank
Max. pressure in heat exchanger

Tank material
Heat exchanger material
Insulation material
Insulation outer surface

Tank diam.
Tank diam. with insulation
Total tank height
Tipping height
Empty weight

42 kg

1075 mm
1233 mm

polyurethane (PU)

Dimensions, tipping height

500 mm
603 mm

95°C 

7 bar
15 bar

Materials

stainless steel AISI 316L
stainless steel AISI 304
EPU (expanded polyurethane)

Technical Data

171 l
162 l
9 l
2 m

2

95°C 

162 l

Main Features

heating of domestic hot water
stainless-steel hot water storage tank with 

upward outlets, integrated inner heat exchanger 

and drain valve
water (tank); water, water-glycol mixture (max. 

1:1) or water - glycerine mixture (max. 2:1) (HE)

17615

Energy Efficiency Data (as per EC Regulation No. 812/2013)

NBC 170 HP
B
42 W

R E G U L U S spol. s r.o. Czech Republic

Do Koutů 1897/3, 143 00 Praha 4

Tel.: +420 241 765 191

Fax: +420 241 763 976

E-mail: [email protected]

Web: www.regulus.eu

Содержание NBC 170 HP

Страница 1: ...www regulus eu NBC 170 HP NBC 170 HP EN Installation and Operation Manual HOT WATER STORAGE TANK NBC 170 HP...

Страница 2: ...mal insulation 3 1 4 Connection points on the tank 3 1 5 Packaging 3 2 General Information 3 3 Technical Data and Dimensions of NBC 170 HP 4 4 Operation 6 5 Examples of Assigning Connection Points 6 6...

Страница 3: ...U insulation white surface 1 4 Connection points on the tank 2 top with G 3 4 inner thread for the heating coil 2 top with G 3 4 inner thread for cold water inlet and hot water outlet 1 top for temper...

Страница 4: ...s NBC 170 HP Hot Water Storage Tank code 17615 pos connections height mm W1 G 3 4 F 1060 mm W2 G 3 4 F 1060 mm W3 G 3 4 F 1060 mm X1 G 3 4 F 1060 mm X2 G 3 4 F 1060 mm C1 G 1 2 F 1060 mm A1 G 3 4 F 10...

Страница 5: ...al Heat exchanger material Insulation material Insulation outer surface Tank diam Tank diam with insulation Total tank height Tipping height Empty weight 42 kg 1075 mm 1233 mm polyurethane PU Dimensio...

Страница 6: ...perature should be set to 55 60 C This temperature guarantees the best operation and at the same time it prevents formation of Legionella bacteria 5 Examples of Assigning Connection Points Table of li...

Страница 7: ...nk instead of the magnesium one 6 4 Commissioning Earth the tank before commissioning The earthing screw is located at the marked place Fill the entire system with liquids and air vent Check all conne...

Страница 8: ...the tank connection points 9 Disposal Packaging shall be disposed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of as household waste It s...