Procedure for conversion of the load unit to connect the thermal store from
the right
1
Remove the top part of insulation.
2
Loosen the nut and remove the extension
for the outlet to the thermal store (this
will be used in step 8).
3
On the right and left side of the insulation
body there are insulated passage points
for connecting the thermal store; take
out the insulation pieces from both the
passage points.
4
Loosen the nut and turn the elbow to
the right.
5
Take out the insulation piece for the
boiler pump. Loosen the nuts at both the
discharge and suction ports of the pump
so that you can easily handle the pump.
6
Move the pump to the side to allow free
access to the elbow.