Regulus 17898 Скачать руководство пользователя страница 4

4.

Pump Station Components

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

3.

Pump Station Pressure Drop Graph

 

1 -

2 -

3 -

4 -

5 -

6 -

7 -

8 -

9 -

10 -

11 -

12 -

13 -

14 -

15 -

BALL VALVE

SOLAR CIRCULATION PUMP

NON-RETURN VALVE

FILL/DRAIN HOSE SOCKET

BALL VALVE WITH T-BRANCHE FOR 

SAFETY ASSY

THERMOMETER (IN INSULATION UPPER 

PART)

PRESSURE GAUGE

EXPANSION VESSEL CONNECTION POINT, 

¾” M

6 BAR SAFETY VALVE

FILLING BALL VALVE

SPANNER FOR BALL VALVES

DRAIN BALL VALVE

SRS1 T ELECTRONIC CONTROLLER 

EL. BOX W. POWER PLUG TO CONNECT 

A SWITCHED HEAT SOURCE

SAFETY VALVE DISCHARGE PIPE, 22 mm 

diam.

Содержание 17898

Страница 1: ...Installation and Operation Manual CSE SOL W SRS1 T K SOLAR PUMP STATION 2 20 l min w electronic control flow rate measurement EN CSE SOL CSE SOL www regulus eu ...

Страница 2: ...sumer 4m cable solar temperature sensor 2m cable silicone insulation 230V power cable w el plug 3m cable PVC insulation Flow measurement Installation The pump sends electronic information on the flow rate to the controller which then shows the indicative value on its display Water glycol mixture max 1 1 Tank mount or wall mount G 3 4 M Codes in relation to a connection size Connection Code 17899 G...

Страница 3: ... from the pressure gauge to the middle of the collector array m the pump station may be used also for systems with a higher flow rate than 20 l min then the controller will show the flow rate value as 20 l min Temperature Resistance Table for Pt1000 Sensors Min working pressure values Pump Station internal wiring 6 8 kg L N live neutral RI R potential free switching contact V S3 S2 S1 Vi iPWM feed...

Страница 4: ...NON RETURN VALVE FILL DRAIN HOSE SOCKET BALL VALVE WITH T BRANCHE FOR SAFETY ASSY THERMOMETER IN INSULATION UPPER PART PRESSURE GAUGE EXPANSION VESSEL CONNECTION POINT M 6 BAR SAFETY VALVE FILLING BALL VALVE SPANNER FOR BALL VALVES DRAIN BALL VALVE SRS1 T ELECTRONIC CONTROLLER EL BOX W POWER PLUG TO CONNECT A SWITCHED HEAT SOURCE SAFETY VALVE DISCHARGE PIPE 22 mm diam ...

Страница 5: ...ircuit bringing about stagnation and subsequent solar fluid degradation The ball valves are fitted with a gland with 2 O rings 8 7x1 8 mm that can be easily replaced after the control element with stops is removed and the gland nut released using a 21 spanner WARNING IMPORTANT When the red mark is on the left hand side the non return valve is set to normal operation position If you need to open th...

Страница 6: ...r pump station is designed to be installed on a wall or on a tank There are two installation openings in the insulation rear part The lower one is accessible only after the electronic controller is removed from the insulation rear part see fig S1 R1 relay S1 solar collector sensor S2 solar consumer sensor S3 afterheating recirculation sensor cable with a dedicated socket to connect a switched heat...

Страница 7: ...er supply lower higher than 230 V 2 electric short circuit in pump 3 pump overheated 1 rotor is blocked 2 electric motor winding defect 1 unforced fluid circulation through the pump 2 pump speed lower than desired 3 air in pump 2 4 6 NOTE The numbering of variants corresponds to the numbering of preset variants in the SRS1 T controller The missing variants 1 3 and 5 are present in the controller b...

Страница 8: ... 4700 P W 1 0 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51 57 54 0 1 2 H m Q l min 3 4 5 6 7 8 0 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45 48 51 57 54 15 25 35 45 55 65 75 85 1 95 8 2 Performance Curves for Para ST 25 7 50 iPWM2 Pump 8 NOTE 1 value of PWM signal in 2 speed in rpm ...

Страница 9: ...ition is marked in red The ball valves are operated by means of a lever handle During normal operation both are in the open position To fill the solar thermal system close the ball valve above the pump by turning the lever handle clockwise by a quarter turn After filling the solar thermal system turn the lever handle counter clockwise to re open the valve Prior to commissioning the system both the...

Страница 10: ...v1 2_03 2020 2020 We reserve the right to errors changes and improvements without prior notice E mail sales regulus eu Web www regulus eu ...

Отзывы: