Regulus 16942 Скачать руководство пользователя страница 4

 

4

REGULUS - Single-phase heating element - www.regulus.eu

2.3 - Connection to power supply

The electric heating element connects to a solar controller connector 1/N/PE AC 230V 50Hz by a flexible 

power cord. Do not use the element if the power supply cord or connector is damaged. All repairs shall be 

performed by a specialized company.

2.4 - Wiring diagram

2.4.1 - Wiring diagram of the heating element

2.5 - Commissioning, operation and possible faults

WARNING!

 

THE OUTGOING HOT WATER SHALL NOT BE LEAD THROUGH COMMON PLASTIC PIPES. THE PIPING 

USED SHALL BE RESISTANT TO TEMPERATUREs OF 100 °C AT LEAST.
IF PLAIN COMMON PLASTIC PIPING IS USED, ITS SERVICE LIFE IS SIGNIFICANTLY REDUCED UN-

DER TEMPERATURES OVER 60 °C. WHEN COMBINED WITH IMPROPER PIPE FIXING THAT PRE-

VENTS/RESTRICTS ITS DILATATION, THE PIPE SERVICE LIFE MIGHT BE JUST SEVERAL HOURS!
IN ORDER TO TIGHTEN THE HEATING ELEMENT, NEVER GRASP ON THE PLASTIC BOX BUT USE 

THE HEXAGON INSTEAD.

Water in direct contact with the heating element shall not exceed the values given in the chart below. The 

manufacturer bears no responsibility for defects (e.g. limescale deposits on the heating element) caused by 

unsuitable operation conditions.
Table of limit values for total dissolved solids in hot water

Description

pH

Total dissolved solids (TDS)

Ca

Chlorides

Mg

Na

Fe

Max. value

6.5-9.5

600 mg/l

40 mg/l

100 mg/l

20 mg/l

200 mg/l

0.2 mg/l

Содержание 16942

Страница 1: ...www regulus eu 1ph heating element w conn switch 1ph heating element w conn switch EN Installation and Operation Manual SINGLE PHASE HEATING ELEMENT with connector and switch ...

Страница 2: ...ctor and switch 3 2 1 Technical description 3 2 2 Dimensions 3 2 3 Connection to power supply 4 2 4 Wiring diagram 4 2 4 1 Wiring diagram of the heating element 4 2 5 Commissioning operation and possible faults 4 2 5 1 DHW heating in a hot water storage tank 5 2 5 2 Heating fluid heating in a thermal store 5 2 5 3 Heating element state during operation 5 2 5 4 Possible faults 5 ...

Страница 3: ...he mains 1 4 Disposal IMPORTANT INFORMATION ON PROPER DISPOSAL OF E WASTE AS REQUIRED BY THE EC DIRECTIVE 2002 96 EC WEEE Do not dispose of this product as unsorted municipal waste Please dispose of this product by returning it to the point of sale or to your local municipal collection point for recycling Respecting these rules will help to preserve protect and improve the quality of the environme...

Страница 4: ...EAST IF PLAIN COMMON PLASTIC PIPING IS USED ITS SERVICE LIFE IS SIGNIFICANTLY REDUCED UN DER TEMPERATURES OVER 60 C WHEN COMBINED WITH IMPROPER PIPE FIXING THAT PRE VENTS RESTRICTS ITS DILATATION THE PIPE SERVICE LIFE MIGHT BE JUST SEVERAL HOURS IN ORDER TO TIGHTEN THE HEATING ELEMENT NEVER GRASP ON THE PLASTIC BOX BUT USE THE HEXAGON INSTEAD Water in direct contact with the heating element shall ...

Страница 5: ...eady again 2 5 4 Possible faults If the tank gets overheated without any other heat source used the solar controller probably does not turn off the heating element when the set temperature is reached call your service provider If the heating element shows signs of another defect disconnect it from the mains immediately and call your service provider 2 5 1 DHW heating in a hot water storage tank In...

Страница 6: ...t be submitted together with the purchase receipt 4 The warranty is valid only when the technical conditions set by the Manufacturer installation manual and instructions in the documentation and on the product itself are respected 5 The warranty does not cover defects caused by external conditions or improper working conditions defects caused by normal wear and tear further when the product is not...

Отзывы: