TT-S4/D

1877E FEB 02

INSTRUCTION

INSTRUCTION

Fig 3

TTC25X

TTC40FX

TT-S4/D

8
9

14
15
19

10 - 2V DC in

+
0

20
21

13

1

2

3

4
5
6

7

8

9

10

11

12

13
14

15

16

17
18

22

23
24

19
20

21

Relay 1 out

Relay 2 out

Relay 4 out
Not connected
Relays 1-4 common in

Not connected

Not connected

Neutral

Not connected
Not connected

Supply

voltage

Relay 3 out

0 - 10V DC input

Signal conv. 10-2V DC in

Signal neutral
Not connected

0 - 10V DC output

Signal neutral

Not connected

Not connected

24V AC in

Not connected

Not connected

Not connected

Signal conv. 0-10V DC out

Function

On an increasing input signal TT-S4/D will first increase the 0 - 10V
output signal. If the power demand becomes so large that the output
signal would need to be larger than 10V, the TT-S4/D will activate
the first relay. The output is held at 0V for 10 seconds and is then
set to an output corresponding to the part of the output signal that
would have been larger than 10V.
In order to get the best control possible the TT-S4/D automatically
sets the amplification between the input signal and the output signal
to suit the maximum number of relay outputs used. At an input signal
of 10V the number of relays set on the rotary switch will be activated
and the output signal will be at 10V.
TT-S4/D will only increase or decrease the relay outputs one at a
time with a time delay of 10 seconds between steps. Change of
direction i.e. from increasing power demand to decreasing power
demand or vice versa is delayed 30 seconds to minimize the risk of
unwanted instability.

Test function

Turn off the supply voltage to TT-S4/D and set the rotary switch to
position 0. Set the Binary/Sequential switch to the position suited to
the heater on hand.
Reconnect the supply voltage.
All relays should now be deactivated and the output signal equal to
0V.

N.B. 

It is normal for the LEDs to wink faintly even when they are

unactivated.
By twisting the rotary switch clockwise the relays are activated in
sequence and the output signal on terminal 19 will increase from 0
when the switch is in position 0,  to 10V when the switch is in
position 15 for binary mode, or 4 and above for sequential mode.

N.B. 

On completion of the test function:

Turn off the supply voltage to the TT-S4/D.
Set the switches to positions suitable for the installation.
Reconnect the supply voltage.
If this is not done the TT-S4/D will remain in testmode.

EMC emissions & immunity standards

This product conforms with the requirements of European EMC
standards CENELEC EN 50081-1 and EN 50082-1 and carries
the CE mark.

LVD

This product conforms with the requirements of European LVD
standards IEC 669-1 and IEC 669-2-1.

Содержание TT-S4/D

Страница 1: ...rkningsf rh llandet mellan insignalen och utsignalen efter inst llningen p maxstegsomkoppla ren Plint 19 0 10V DC ut Plint 21 signalnoll Rel utg ngar Rel er 1 4 enpoligt slutande med gemensam matning...

Страница 2: ...sp nningen p analog utg ngen skall vara 0V OBS Det r normalt att samtliga lysdioder blinkar svagt i fr nslaget l ge Genom att vrida omkopplaren medurs tvingas rel stegen in i tur och ordning Dessutom...

Страница 3: ...f the maximum step switch Terminal 19 0 10V DC output Terminal 21 Signal neutral Relay outputs Relays 1 4 SPST with a common supply pole 240V AC 2A total When the heater is binary divided the loads mu...

Страница 4: ...output signal will be at 10V TT S4 D will only increase or decrease the relay outputs one at a time with a time delay of 10 seconds between steps Change of direction i e from increasing power demand t...

Страница 5: ...me 21 Signal neutral Relaisausg nge Relais 1 4 SPST mit einem gemeinsamen Wurzelkontakt 240V AC 2A gesamt Wird die Last bin r geschalten m ssen die Heizst be in ansteigender Reihenfolge angeschlossen...

Страница 6: ...sollten nun inaktiv und das Ausgangssignal 0V sein Beachte Es ist normal da die LEDs schwach glimmen auch wenn diese inaktiv sind Wenn Sie den Drehschalter im Uhrzeigersinn drehen aktivieren die Relai...

Страница 7: ...r e et le signal de sortie apr s le r glage du s lecteur du nombre d tages max Borne 19 sortie 0 10 Vdc Borne 21 neutre du signal Sorties relais Relais 1 4 unipolaire et normalement ouverts avec un p...

Страница 8: ...NOTE Il est normal que tous les voyants clignotent faiblement en position ouverte Tourner le s lecteur dans le sens horaire pour forcer chaque tage relais l un apr s l autre De plus le signal sur la b...

Отзывы: