www.regentlight.co.za
www.regentlight.co.za
2
3
7
8
4
This product should be installed by a competent person i.e. Qualified electrician.
This product requires a constant stable electrical supply 220V - 240V VAC 50Hz - alternating current.
The product must be regularly maintained, including the replacement of lamps/LED timeously.
This product could be HAZARDOUS if not used correctly, it could cause electric shock, serious bodily harm or death.
This product is not a toy, please keep away from children.
This product may contain small parts that can be swallowed.
Use only the correct light bulbs/LED as stipulated on the carton for the product.
Any modifications of this product after supply will result in the guarantee being void.
Spare parts may become unavailable over time.Items can vary slightly from the picture on the carton
Coastal humidity can affect the longevity of the light fitting over time.
Be sure to follow the steps in the order given.
Read instructions carefully.
Important Safety Instructions
4. Once securely fastened to
the bolt cage, adjust the
individual lights vertically
and horizontal ly.
Loosen the stainless steel
f a s t e n e r s a n d a n g l e
a c c o r d i n g l y . O n c e t h e
desired angle is chosen,
fasten the stainless steel
f a s t e n e r s t o s e c u r e t h e
angle.
Loosen/tighten
screw
5
5. Switch on the power
supply.
Loosen/tighten
screw
x2 Hook bolts
Blank base plate
Bolt hook nuts
Assembly of buried base plate
A
B
C
2. Assemble the base plate
(supplied) to be buried in the
ground, using the stainless
steel hook bolts and nuts
(supplied).
Hook the two hook bolts into
the allocated holes on the
bollard. Slide the blank base
plate onto the hook bolts at
the bottom of the pole. Align
and fasten the hook bolts
using the nuts.
Ensure the electrical cable
tail is fed through the bollard
and base plate.
Mains to
Luminaire
Earth Loop
Green/Yellow
Switch
Wire Red
Neutral loop
Black or Blue
(L) Brown
(E) Green/Yellow
(N) Blue
Cable
Tail
Pole
Cable Joining kit
Ground
Level
Tail supplied
3. Using the electrical power
supply cable tail from the
b o l l a r d , c o n n e c t t h e
electrical cable to the cable
joint. Bury the bollard in the
ground. Ensure the bollard is
secure.
Ensure that there are no
exposed conductors, loose
strands or trapped/pinched
insulation
SWITCHED LIVE – (Red or Brown)
to terminal marked L
NEUTRAL – (Black or Blue) to
terminal marked N
EARTH – (Green/Yellow) to
terminal marked
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.