F2400/S2400 Freestanding Woodfire
19
installation
1)
Remove the two screws from the top of the
fan housing.
2)
Slide the fan up into the rear heat shield.
3)
After aligning holes, secure the fan to the rear
heat shield using the two screws removed
earlier.
CAUTION: The connection cord should not
be in contact with any hot surfaces.
Do not route cord under or in front
of unit.
Read the operating instructions for the fan before
using. See Page 19.
Ground
Fan
Fan
Ground
Green
Neutral
Live
Whit
e
Fan
Switch
Manual/
Auto
Switch
Black
Black
High
(Black)
Low
(Red)
Black
Fan Thermodisc
(normally open)
120V AC
60 Hz
Blower/Fan Wiring Diagram
Wire98gr.eps
updated Jan. 27/00
updated: Aug. 09/05
capitalized the word Nut
Lockwasher
Ground wire
from power cord
Ground wire
from fan
#8 Groun Lug
d
Star washer
Nut
Nut
Star washer
Grounding
Lug Detail
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
Содержание Vancouver
Страница 3: ...F2400 S2400 Freestanding Woodfire 3 Modular Parts ...
Страница 32: ...32 F2400 S2400 Freestanding Woodfire ...
Страница 33: ...F2400 S2400 Freestanding Woodfire 33 NOTES notes ...
Страница 34: ...34 F2400 S2400 Freestanding Woodfire NOTES notes ...
Страница 35: ...F2400 S2400 Freestanding Woodfire 35 ...