8
Regency
®
U39 ULTIMATE Direct Vent Freestanding Gas Stove
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The ULTIMATE Direct Vent Freestanding Gas
Stove must be installed in accordance with these
instructions. Carefully read all the instructions in this
manual fi rst. Consult the building authority having
jurisdiction to determine the need for a permit prior
to starting the installation.
Note: Failure to follow the instructions could
cause a malfunction of the heater which
could result in death, serious bodily
injury, and/or property damage. Failure
to follow these instructions may also
void your fi re insurance and/or warranty.
Note: These instructions take preced-ence over
Simpson Dura-Vent instructions.
SPECIFICATIONS
Fuels:
U39-NG1 is approved for use with natural
gas.
U39-LP1 is approved for use with liquefi ed
petroleum gases (propane).
Electrical:
120V A.C. system.
Circulation Fan:
Variable speed, 125/75.
Log Sets:
Ceramic fi bre, 7 per set.
Vent System:
Coaxial (6-5/8" outer / 4" inner liner)
rigid fl ue and termination cap.
INFORMATION FOR
MOBILE/
MANUFACTURED HOMES
AFTER
FIRST SALE
This Regency
®
product has been tested and listed
by Warnock Hersey as a Direct Vent Wall Furnace
to the following standards: CAN/CGA-2.17-M91 and
ANSI Z21.88a-2007/CSA 2.33a-2007.
This Direct Vent System Appliance must be
installed in accordance with the manufacturer's
installation instructions and the Manufactured Home
Construction and Safety Standard, Title 24 CFR,
Part 3280, or the current Standard of Fire Safety
Criteria for Manufactured Home Installations, Sites,
and Communities ANSI/NFPA 501A, and with CAN/
CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with
the manufacturer's installation instructions and
local codes, if any. In the absence of local codes
follow the current National Fuel Gas Code, ANSI
Z223.1 and the current National Electrical Code
ANSI/NFPA 70 in the U.S.A., and the current
CAN/CGA B149 Gas Installation Code and the
current Canadian Electrical Code CSA C22.1
in Canada.
This Regency
®
Mobile/Manufactured
Home Listed appliance comes factory
equipped with a means to secure the unit.
1)
Provide adequate clearances for servicing,
proper operation and around the air openings
into the combustion chamber.
2)
The appliance may be installed on a fl at, solid,
continuous surface (e.g. wood, metal, concrete).
This may be the fl oor, or it can be raised up on
a platform to enhance its visual impact. The
appliance may be installed on carpeting, tile,
wood fl ooring or other combustible material,
because the appliance's metal pedestal base
extends the full width and depth of the appliance.
The ULTIMATE Direct Vent Freestanding Gas
Stove can be installed in a wide variety of ways
and will fi t nearly any room layout. It may be
installed in a recessed position, framed out into
the room, or across a corner.
3)
The ULTIMATE Direct Vent Freestanding Gas
Stove is approved for alcove installations, which
meet the clearances as listed in the "Locating
Your Ultimate Gas Stove" section. This unit is
approved for manufactured home installations,
see "Rigid Pipe Venting Arrangements" section
for the required vent arrangements. If installed
into a manufactured home the unit must be
bolted down to the fl oor.
4)
This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Some areas may have further requirements,
check local codes before installation.
5)
This appliance is Listed for Alcove installations,
maintain minimum Alcove clearances as follows,
minimum width of 48" (1219mm), a maximum
depth of 36" (914mm), and minimum ceiling
height of 64"(1626mm).
6)
We recommend that you plan your installation on
paper using exact measurements for clearances
and fl oor protection before actually installing this
appliance. Have a qualifi ed building inspector
review your plans before installation.
This Regency
®
Mobile/Manufactured
Home listed appliance comes equipped
with a dedicated #8 ground lug to which
an 18 gauge copper wire from the steel
chassis ground must be attached.
This appliance may only be installed
in an aftermarket permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only use with the type
of gas indicated on the rating plate.
This appliance is not convertible for
use with other gases, unless a certifi ed
kit is used.