 P121E-11/P131E-11 Zero Clearance Direct Vent Gas Fireplace

  |    

21

installation

Exterior Vent Termination Locations

Minimum Clearance Requirements

Canada

1

USA

2

A

Clearance above grade, veranda, porch, deck, or balcony

12"(30cm)

12"(30cm)

B

Clearance to window or door that may be opened

 12"(30cm)

9" (23cm)

C

Clearance to permanently closed window

*

*

D

Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm)
 from the center line of the terminal (check with the local code)

18"(46cm)

18"(46cm)

E

Clearance to unventilated soffit

20"(51cm)

20"(51cm)

F

Clearance to outside corner: with 

AstroCap

 Termination Cap.

 6"(15cm)

6"(15cm)

Clearance to outside corner: with all other approved Termination Caps.

14"(36cm)

14"(36cm)

G

Clearance to inside corner: with 

AstroCap

 Termination Cap 

6"(15cm)

6"(15cm)

Clearance to inside corner: with all other approved Termination Caps.

12"(30cm) 
13"(33cm)

12"(30cm)

H

Clearance to each side of center line extended above meter/regulator assembly

 36"(90cm)

a

*

J

Clearance to service regulator vent outlet

36"(90cm)

*

K

Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance

12"(30cm)

9" (23cm)

L

Clearance to a mechanical air supply inlet 
 

#3' (91cm) above if within 10' (3m) horizontally.

72"(1.8m)

36"(90cm)

b

M

Clearance above paved sidewalk or a paved driveway located on public property 

   84"(2.1m)

*

N

Clearance under veranda, porch, deck, or balcony 

  12"(30cm)

*

1

  In accordance with current CSA B149.1, 

Natural Gas and Propane Installation Code

2

  In accordance with the current 

ANSI Z223.1/NFPA 54, National  Fuel Gas Code

 A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings

‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor
*  Clearance in accordance with local installation codes and the requirements of the gas supplier

a

  

3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly

b

 3 feet (91cm) above  - if within 10 feet (3m) horizontally      

Содержание Panorama P121E-LP11

Страница 1: ...ch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warni...

Страница 2: ...ch The model P121E P131E 11 has been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace IMPORTANT If the unit is to be installed into a bathroom optiona...

Страница 3: ...Code and the current Canadian Electrical Code CSA C22 1 in Canada This Regency mobile manufactured home listed appliance comes factory equipped with four 1 4 diameter holes located near each corner of the base Fasten the fireplace in place using screw inserted through the holes This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassis as app...

Страница 4: ...t 45 Battery Backup 46 Maintenance Normal Operating Sounds of Gas Appliances 47 Maintenance Instructions 47 Flame Pattern 47 Aeration Adjustment 48 Maintenance Instructions 49 Log Replacement 49 Glass Gasket 49 Door Glass 49 Removal of Valve Assembly 50 Installing Valve 53 Fan Replacement 53 Parts P121E 11 See Thru Main Assembly 54 P131E 11 Pier Main Assembly 55 Burner Assembly Log Set 56 Warranty...

Страница 5: ...pliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details Optional Fan Part 910 171 Installer l appareil selon les codes ou règlements locaux ou en l absence de tels règlements selon les codes d installation ANSI Z223 1 National Fue...

Страница 6: ...et above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation ...

Страница 7: ...Regency P121E 11 P131E 11 Zero Clearance Direct Vent Gas Fireplace 7 dimensions P121E 11 See Thru Note These units are non load bearing ...

Страница 8: ...8 Regency P121E 11 P131E 11 Zero Clearance Direct Vent Gas Fireplace dimensions P131E 11 Pier Note These units are non load bearing ...

Страница 9: ...RIERSISRECOMMEND ED IFTHERE ARE AT RISK INDIVIDUAL INTHE HOUSE TO RESTRICT ACCESS TO A FIREPLACE OR STOVE INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS YOUNG CHILDREN ANDOTHERATRISKINDIVIDUALSOUT OF THE ROOM AND AWAY FROM HOT SURFACES Important Message SAVE THESE INSTRUCTIONS The Panorama P121E P131E NG11 or P121E P131E LP11DirectVentFireplacemustbeinstalled inaccordancewiththeseinstructions ...

Страница 10: ...ximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner 4 The unit will turn on Lighting Procedure Continuous Pilot Intermittent Pilot CPI IPI selection See remote control instructions for details On Demand Pilot seven day safety timer Important information if using the appliance in CPI continuous pilot mode only This appliance is a ProFlame 2 system fitted ...

Страница 11: ...amage personal injury or loss of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas scrupuleusement les instructions de la présente ...

Страница 12: ...Figure 1 Proflame Transmitter Figure 2 Transmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting th...

Страница 13: ...reduce the flame height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as...

Страница 14: ... by the Proflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmab...

Страница 15: ...on system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility to choose a traditional continuous pilot The primary...

Страница 16: ...acturer General Safety Information 1 The appliance installation must conform with local codes or in the absence of local codes with the current Canadian or National Gas Codes CAN1 B149orANSI Z223 1Installation Codes 2 See general construction and assembly instructions The appliance and vent should be enclosed 3 This appliance must be connected to the specifiedventandterminationcaptotheoutside of t...

Страница 17: ...od panel extending the full width and depth of the appliance 4 The DirectVent Gas Fireplace can be installed as follows Model Position A P121E 11 See Thru B P131E 11 Pier 5 ThisapplianceisListedforbedroom installations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 6 The P121E 11 P131E 11 Direct Vent Gas Fireplace is appr...

Страница 18: ...sh with the base of the unit Ceiling Height from Floor 72 1829mm Mantel Height from Base of Unit 39 min 991mm Horizontal Vent Clearances Top 2 1 2 64mm Side 1 1 2 38mm Bottom 1 1 2 38mm Vertical Vent Clearances 1 1 4 32mm Becauseoftheextremeheatthisfireplaceemits the mantel clearances are critical Combustible mantel clearances from top of unit are shown in Diagram to the right Note A non combustib...

Страница 19: ...in a chase apply a vapour barrier and drywall as per local building codes DO NOT INSULATE THE FIREPLACE ITSELF CAUTION The unit does not have to be completely enclosed in a chase The clearance on top of the unit is 0 to the standoffs so combustible building materials can be laid directly on top of the standoffs You must maintain clearance from the vent to combustible materials for both rigid and f...

Страница 20: ...ed See Rigid Pipe Venting Systems for more details and exceptions Unit Assembly Prior To Installation The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position Top Standoff Assembly The top standoffs are shipped in a flat position and must be folded into shape and attached 1 Remove the standoffs from the fireplace top 2 Take each standoff and ben...

Страница 21: ... center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway l...

Страница 22: ...djustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 ...

Страница 23: ...tion 36 N A N A N A N A N A TM 4ST36 N A Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK VDV KW04 Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK VDV K04 Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 ...

Страница 24: ...terior Vent Termination Locations section Regency Direct Vent Flex System Termination Kit Part 946 513 includes all the parts needed to install the P121E 11 P131E 11 with a maximum run of 2 feet If installing the P121E 11 P131E 11 with a continuous vent length of more than 2 ft 6m to a maximum of 10 ft 3 0m use Kit 946 515 4 ft or 946 516 10 ft 1 6 7 8 dia flexible liner 2 ft length 2 4 dia flexib...

Страница 25: ...th inches Required inches 4 5 1 2 6 7 8 1 2 9 10 11 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Pipe When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura Vent Direct Vent Ameri can Metal Products Ameri Vent D...

Страница 26: ...ws examples of horizontal termination arrangements using one two or three 90o elbows two 45o elbows equal one 90o elbow Note 1 A maximum of three 90o elbows are permitted 2 Minimum distance between elbows is 1 ft 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passin...

Страница 27: ...6 1 83m Max C 4 1 22mm Min 5 1 52m Max 9 2 74m Max D 5 1 52m Min 7 2 13m Max 12 3 66m Max With the above options maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal Please note minimum 1 foot between 90o elbows is required Option V H H H1 A 1 305mm Min 1 305mm Max 3 914mm Max B 2 610mm Min 3 0 91m Max 6 1 83m Max C 3 914mm Min 5 1 52m Max...

Страница 28: ...am 7 below Straight Up Vertical Venting Maximum 35 10 7m 6 Minim um 6 6 2 0m 45 Elbow Rigid Pipe Adapter Part 510 994 Vertical Venting with One 1 90o Elbow Diagram 8 IMPORTANT When installing this unit vertically the 45o elbow when installed in conjunction with the Rigid Pipe Adaptor will protrude past the unit 1 1 2 38mm when measured from the rear standoffs Note A 1 1 4 32mm clearance from the e...

Страница 29: ... 1 22m Minimum 8 2 44m Maximum With the above options maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal Please note minimum 1 foot between 90o elbows is required With the above options maximum total pipe length if 37 feet with minimum of 4 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elb...

Страница 30: ...sto combustiblematerialsaremaintained Diagram 3 in the Venting Arrangement Horizontal Terminations section Install the termination cap The four wood screws provided should be replaced with appropriate fasteners for stucco brick concrete or other types of sidings Note If installing termination on a siding covered wall a vinyl siding standoff or furring strips must be used to ensure that the termina...

Страница 31: ...wo sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe Use the two sheet metal screws provided to connect the strips to the pipe section See Diagram 4 9 Install wall thimble in the center of the 10 square and attach with wood screws Diagram 5 Vertical Terminations 1 Maintainthe1 1 4 clearances airspaces to combustibleswhenpassingthroughceilings walls roofs ...

Страница 32: ...allation more a e s t h e t i c a l l y p l e a s i n g w e recommend framing out a square to mount the terminal to Outside Wall Mur extérieur Furring Strips Fourrures en bois Furstrp eps see also c34020a eps furstrpf eps french termination is not recessed into the siding 2 Levelthefireplaceandfastenittotheframing using nails or screws through the nailing strips 3 Assemble the vent assembly by app...

Страница 33: ...NATION 4 X 6 7 8 VENTING VERTICAL FLEX VENT KIT 946 755 11 Secure inner flex pipe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe...

Страница 34: ...m 1 Diagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop A ceiling firestop firestop spacer must be installed when passing through each floor or ceiling level...

Страница 35: ...er assembly by removing the4screws thenslidetheburnerassembly away from the orifice and lift out 9 Reinstall new burner orifice LPG stamped 50 and tighten 3 Remove the grate by lifting straight up Remove the side brick panels if installed The brick panel is very fragile handle with care Installation of LPG Conversion Kit Diagram 1 Diagram 2 Diagram 3 Diagram 4 Diagram 5 13 Reverse steps 4 to 1 14 ...

Страница 36: ... it is always best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually co...

Страница 37: ...attery Holder in the Low Voltage Junction box 5 Install batteries only if 120 volt power will not be used Batteries are only used if power is lost within the home and serve as a secondary power source Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Battery Holder switch in the OFF position to allow correct lineup...

Страница 38: ...ace Log 326 on the front right side of the burner Ensure that the notches on the far right side of the log fit into the grate posts Push back side of the left end of the log up against the tab on the burner Repeat step 3 on the opposite side of the burner 4 Place Log 327 on the front left side of the burner Po sition the right end of the log in between the two tabs and the left end of the log into...

Страница 39: ... the Log onto the second grate post from the left Ensure that the log fits into a pin that is on Log 326 Repeat step 5 on the opposite side of the burner 6 Place Log 328 on the middle right side of the burner Ensure that the log fits over the 2nd grate post from the right Repeat step 6 on the opposite side of the burner 918 111c 01 03 08 LOG SET INSTALLATION P121 P131 Page 2 of 2 Grate Post 328 32...

Страница 40: ...2 Loosen 2 screws in locations shown in Diagram 1 Diagram 1 Diagram 5 Diagram 3 Diagram 2 Diagram 4 3 Lift top bracket up and outward to remove as shown in Diagram 2 5 Loosen the 2 screws as shown in locations shown in Diagram 4 6 Pull the bottom bracket down and outward to remove 4 Remove safety screen by lifting up and out 7 To install reverse steps ...

Страница 41: ... ensure that some room is left to be able to hang the grill or louver over the screw 2 Hang the Top Louver or Grill onto the 2 screws in the top fireplace opening 3 Attach the Bottom Louver or Grill to the hinges on the bottom flange of the fireplace 4 Attach the screws provided to the top and bottom left and right corners similar to step 1 5 Hang the top and bottom louver or grill onto the screws...

Страница 42: ...ed non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not connect millivolt wall thermostat wires to 120V wire Receptacle Location Metal receptacle attached to appliance Receptacle cover supplied with manual package For your convenience a receptacle box has been pro vided which is located on the same side as the gas valve on the vent side of the appliance Also pr...

Страница 43: ...uctions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep tacle Do not cut or remove the grounding prong from this plug Note 4 AA Batteries must be installed into the back up battery compartment however for this unit to operate when power is lost See battery back up instr...

Страница 44: ...able if the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not connect the millivolt wall thermostat wires to the 120V wires Wiring Diagram with Optional Thermostat White Black FAN 2 FAN 1 EXTERNAL ANTENNA GREY GREY Thermostat Optiona...

Страница 45: ...r rectly positioned 7 The unit should never be turned off and on again without a minimum of a 60 second wait This remote control requires coding See remote coding instructions for details NOTE Thisappliancewilloperatewith4AAback up batteriesinstalled seeBack upBatterysection for details during power outages Only the fan will not operate until power is restored If the remote is misplaced the unit c...

Страница 46: ...illips head screws 1 Remove 2 Phillips head screws to remove cover plate Place screws to the side Cover plate not exactly as shown See diagram 1 Diagram 2 Battery compartment door Battery compartment tabs 2 Press down on both tabs to remove battery compartment door See diagrams 2 and 3 Diagram 4 Diagram 3 Battery door removed 3 Install 4 AA batteries ensuring they are polarity correct See diagram ...

Страница 47: ...E ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATUREANDSHOULDSTAY AWAYTOAVOIDBURNSORCLOTH ING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPER VISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE 8 Each time the appliance is lit it may cause con densation and fog the glass This condensation and fog is normal and will disappear in a few minutes as the glass heats up Never operate the appliance wi...

Страница 48: ...ory set but may need adjusting due to either the local gas supply or altitude Minimum Air Shutter Opening 3 16 Natural Gas 3 8 Propane CAUTION Carbon will be produced if air shutter is closed too much Note Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty Closed Tall yellow Open Short Blue Note Aeration Adjustment should only be perfo...

Страница 49: ... Side Door Tempered Part 360 529 Front Door Ceramic Part 360 946 Optional Maintenance Instructions 1 Always turn off the gas valve before cleaning For relighting refer to lighting instructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brushasthelogsarefragileandeasilydamaged 2 Clean appliance and door ...

Страница 50: ...ews once on each side of the door 5 With the glass door removed from the unit remove the logs Once the logs have been removed remove the grate around the burner by lifting grate straight up and out 3 Once the top and bottom trim pieces have been removed remove the side trim pieces that are held in with magnets Simply pull the trim pieces out with some force to dislodge the magnet from the trim 6 R...

Страница 51: ...ield has been removed disconnect the stepper motor from the IFC at terminal X6 and the spark electrode wire from X2 as well as the flame sensor wire from terminal X 3 9 To remove the valve assembly from the unit remove 16 Phillips head screws securing the valve tray to the unit 8 Once the burner has been loosened from the mounting brackets slide the burner off the orifice by sliding the burner rig...

Страница 52: ...e mounting bracket 2 Once the valve has been removed from the mounting bracket discon nect the pilot nut with 11mm 7 16 wrench Remove Valve only 3 Then remove burner supply tube from 90 degree brass fitting on valve with 15mm 5 8 wrench 4 Once the supply tube has been removed from the 90 degree brass fitting remove the 90 degree brass fitting from the valve with a 17mm 11 16 wrench Note orientatio...

Страница 53: ...hut off power by disconnecting 3 prong plug at receptacle inside of the appliance 2 Remove top louvers 3 Unplug power wires 4 Remove 4 screws securing fan to mounting bracket 5 Remove 2 connector wires 6 Replace fan 7 Repeat for opposite side corner 8 Reverse steps 1 5 for installation Connector wires ...

Страница 54: ...ront 10 360 047 Nailing Strip Top Side 11 430 001 Standoff Top 17 360 086 Gasket Relief Door 24 Relief Door Assembly 32 362 528 Brick Panel Base Set of 4 34 902 603 Brick Panel Std Red Side Part Description 135 360 069 Heat Shield Side 146 360 033 Left Side Door Trim 360 034 Right Side Door Trim 150 360 123 Magnet Bracket Front 151 904 258 Magnet 168 360 068 Door Cover Assembly Side 171 360 920 Lo...

Страница 55: ...Top Side 11 430 001 Standoff Top Part Description 17 360 086 Gasket Relief Door 24 Relief Door Assembly 32 362 528 Brick Panel Base Set of 4 34 902 603 Brick Panel Side Std Red 141 360 031 Column Finishing Trim 146 360 034 Door Trim Right 147 360 033 Door Trim Left 148 360 035 Finishing Trim 149 360 122 Magnet Bracket Corner 150 360 123 Magnet Bracket Front 151 904 258 Magnet Part Description 171 ...

Страница 56: ...1 NG 904 641 Orifice 50 LP 936 170 Orifice Gasket 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 911 010 Stepper motor NG 911 011 Stepper motor LP 910 432 Pilot tube with nuts 911 039 2 way pilot hood 911 037 Flame Sensor 911 038 Spark Electrode 911 187 Remote Battery Box 911 127 Remote battery compartment door 911 175 GTMF Remote control Hand held W840470 Pilot assembly gasket 911 192 120 Volt...

Страница 57: ...Regency P121E 11 P131E 11 Zero Clearance Direct Vent Gas Fireplace 57 notes ...

Страница 58: ... Ignition Control Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI ...

Страница 59: ...mages downdrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunctio...

Страница 60: ...ted outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please ...

Страница 61: ...ormation below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email F...

Страница 62: ...62 Regency P121E 11 P131E 11 Zero Clearance Direct Vent Gas Fireplace warranty ...

Страница 63: ...Regency P121E 11 P131E 11 Zero Clearance Direct Vent Gas Fireplace 63 ...

Страница 64: ..._______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency and Panorama are trademarks of FPI Fireplace Products International Ltd Copyright 2019 FPI Fireplace Products International Lt...

Отзывы: