P48  Zero Clearance Direct Vent Gas Fireplace

Model

P48-NG2

P48-LP2

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (3.00 kPa)

Manifold Pressure - High

3.8” W.C. (0.95 kPa)

11” W.C. (2.74 kPa)

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

3.3” W.C. (0.82 kPa)

Orifi ce Size

#27 DMS - 0-4500ft

#47 DMS

Minimum Input 

29,000 BTU/h (8.49 kW)

26,000 BTU/h (3.07 kW)

Maximum Input

51,000 BTU/h (14.94 kW)

48,000 BTU/h (6.30 kW)

Vent Sizing

5” Inner / 8” Outer

5” Inner / 8” Outer

A

B

A

D

C

F

E

G

H

I

K

J

L

O P

N

M

11" (279mm)

dia. Hole through

wall Vent.

Opening for gas

connection

Top Header

Drywall

(or other

facing)

P48 Gas Fireplace

Unit Dimensions

Description

P33

A

Front Face Width

48” (1219mm)

B

Rear Firebox Width

34-1/2” (876mm)

C

Front Face Height

41” (1041mm)

D

Height w/ Standoff

47” (1193mm)

E

Unit Depth

23-1/4” (324mm)

F

Firebox Height

40” (1016mm)

Framing Dimensions

Description

P33

G

Framing Width

48-1/2” (1232mm)

H

***

Framing Height

***

47-1/2” (1207mm)

***

I

Framing Depth

29-3/4” (756mm) 

Vertical Rise

26-1/4” (667mm) 

No Vertical Rise

 

J

Corner Wall Length

57-5/8

 

” (1464mm)

K

Corner Facing Wall Width

81-1/2” (2070mm)

L

Framed Chase Ceiling

N/A - 

Vertical Rise

50” (1270mm) 

No Vertical Rise

 

M

Vent Centerline Height

43” (1092mm) 

N

Gas Connection Height

2” (51mm)

O

Gas Connection Inset

3-3/4” (95mm) 

P

Gas Connection Width

5” (127mm) 

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Dura-Vent® Direct Vent GS

***

Important:  Framing height requires consideration of the hearth 

depth.   Dimension H = H + the thickness of installed hearth.

Please refer to Page 11 (Exterior Vent Terminations) 

for additional guidelines on vent locations.

61

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Содержание P48-LP2

Страница 1: ...eight w Standoff 47 1193mm E Unit Depth 23 1 4 324mm F Firebox Height 40 1016mm Framing Dimensions Description P33 G Framing Width 48 1 2 1232mm H Framing Height 47 1 2 1207mm I Framing Depth 29 3 4 756mm Vertical Rise 26 1 4 667mm No Vertical Rise J Corner Wall Length 57 5 8 1464mm K Corner Facing Wall Width 81 1 2 2070mm L Framed Chase Ceiling N A Vertical Rise 50 1270mm No Vertical Rise M Vent ...

Страница 2: ...ojection 3 1 1 2 Mantel Leg Clearances Combustible mantel leg clearances as per diagram below Clearances are from the finished edge of the unit Maximum 1 projection at 3 minimum clearance Mantel Clearances A B C D Front 41 1041mm 15 381mm 10 254mm 8 203mm P48 Gas Fireplace WARNING Failure to maintain required clearances is a major cause of chimney related fires Installation of this fireplace must com...

Страница 3: ...Flex Horizontal Terminations Only These venting systems in combination with the P48 Direct Vent Gas Fireplace have been tested and listed as a direct vent heater system by Warnock Hersey The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram FPI Direct Vent Flex System Termination Kits include all the parts needed to install the P48 using a flexi...

Страница 4: ... shaded area 6 8 2 0 4 10 12 in the diagram shows allowable venting configurations using 45 and one 90 elbow Vent must be supported at offsets Horizontal sections must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustible materials Minimum of 1 pipe section between elbows Note Must use optional flue adapter when us...

Страница 5: ... Min Vertical Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 Min ...

Страница 6: ...ote Must use optional flue adapter Part 770 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes Note FPIDirectVentSystem Flex isonlyapprovedforhorizontal te...

Страница 7: ...orizontal Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 2 Min 1 Max 3 Min 4 Max B 3 Min 2 Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 Mi...

Отзывы: