Regency
®
P40-1 Direct Vent Gas Fireplace
11
INST
ALLA
TION
INSTALLATION
10-1/4” Above Fireplace
6”
6”
Diagram 1
1)
Frame in the enclosure for the unit with framing material. The framed
opening for the assembled kit is 42-1/2" high x 40-1/2" wide x 20-1/16"
deep (1080mm H x 1029mm W x 508mm D), see Diagram 1. Also
see Diagram 2 for corner installations.
Note: When constructing the framed opening, please ensure there
is access to install the gas lines when the unit is installed.
See diagram 3 for details.
2)
For exterior walls, insulate the enclosure to the same degree as the
rest of the house, apply vapour barrier and drywall, as per local instal-
lation codes.
(Do not insulate the
fi
replace itself.)
3)
The unit does not have to be completely enclosed in a chase. A non-
combustible header must be used. You must maintain clearances
from the vent to combustible materials: See "Clearances" section.
Combustible materials can be laid against the side and back standoffs
and the stove base.
FRAMING & FINISHING
42-1/2"
(1080mm)
40-1/2”
(1029mm)
Min. 20-1/16"
(508mm)
Non-Combustible
Header
(On Edge)
Non-Combustible Studs
(when installing the full screen front only)
The
HeatWave
Duct Kit has different
clearance and framing requirements,
check the
HeatWave
manual for details.
Diagram 2
Diagram 3
Note: Height is from the base of the unit. Take into consideration
the hearth height and material.
Height = 42-1/2" plus height of hearth.
WARNING: When installing the Full Screen Doors
The Full Screen Front requires additional non combustible facing and
non-combustible framing. Ensure the 10-1/4" above the
fi
replace, 6"
on both sides and both the header and side studs are non-combustible
materials. All other clearances, including mantel, remain the same.
WARNING: When installing the
Full Screen Doors
The Full Screen Front requires
additional non combustible facing
and non-combustible framing.
Ensure the 10-1/4" above the
fi
replace, 6" on both sides and
both the header and side studs
are non-combustible materials.
All other clearances, including
mantel, remain the same.
FULL SCREEN DOOR
FACING REQUIREMENTS