L676-1 Sunrise Gas Fireplace

Regency L676-1 Sunrise Gas Fireplace

Clearance:

Dimension

Measured From:

A: Mantel Height

16-1/2” (419mm)

Minimum 

B: Sidewall

14-3/4” (375mm)

Side of 

fi

 replace opening

C: Ceiling

52” (1321mm)

Top of 

fi

 replace opening

D: Mantel Depth

13” (330mm)

Maximum 

E: Alcove Width

84” (2134mm)

Sidewall to Sidewall (Minimum)

F: Alcove Depth

36” (914mm)

Front to back wall (Maximum)

Clearance Requirements:

Combustible Mantels

Because of the extreme heat this 

fi

  replace emits, the mantel clearances 

are critical.

 Combustible mantel clearances from top of the front facing 

are shown in the diagram below. Mantel may be installed anywhere in the 
shaded area or higher.

Mantel Leg 

Clearances

Combustible mantel leg 
clearances as per diagram. 

Clearances are from the 

fi

 nished edge of the 

fi

 replace 

opening.

Mantel 
Clearances

From Top of 

Fireplace Opening

A

31-1/16”

B

26-1/2” 

C

17-1/2” 

D

16-1/2”

Note: 

A non-combustible mantel may 
be installed at a lower height if 
the framing is made of metal 
studs covered with a non-com-
bustible board.

Ensure the paint that is used 
on the mantel and the facing is 
“heat resistant” or the paint may 
discolour.

Vertical Terminations:

Horizontal Terminations:

Installed 

Close to Floor

Installed Close 

to Ceiling