INSTALLATION

CHIMNEY 

SPECIFICATIONS

Before installing, check and clean your chimney 
system thoroughly. If in doubt about its condi-
tion, seek professional advice. Your Regency 
Insert is designed for installation into a masonry 

fi

 replace that is constructed in accordance with 

the requirements of "The Standard for Chimneys, 
Fireplaces, Vents, and Solid Fuel Burning Ap-
pliance", N.F.P.A. 211, the National Building 
Code of Canada, or the applicable local code 
requirements.  

The appliance, when installed, must be electri-
cally grounded in accordance with local codes or, 
in the absence of local codes, with the National 
Electrical Code, ANSI/NFPA 70, or the Canadian 
Electrical code, CSA C22.1.

Regency Inserts are designed to use either a 
5.5" (140mm) or  6" (152mm) 

fl

 ue.

Requirements for Installing 

Solid-fuel Inserts in Factory-built 

Fireplaces.

1)

  The insert must be tested and meet the 

requirements of UL 1482 (U.S.) and or ULC 
S628 (Canada) when tested in a masonry 

fi

 replace built per ULC S628.

2)

 The 

factory-built 

fi

 replace must be listed per 

UL 127 or ULC S610.

3)

  Clearances obtained from the masonry 

fi

 re-

place tests are also relevant for installation 
in factory-built 

fi

 replaces.

4)

  Installation must include a full height listed 

chimney liner type HT requirements (2100 
degree F.) per UL 1777 (U.S.) or ULC 
S635 (Canada). The liner must be securely 
attached to the insert 

fl

 ue collar and the 

chimney top.

5)

  Means must be provided to prevent room 

air passage to the chimney cavity of the 

fi

 replace. This may be accomplished by 

sealing the damper area around the chimney 
liner, or sealing the 

fi

 replace front.

6)

  Alteration of the 

fi

 replace in any manner is not 

permitted with the following exceptions; 

 

a. 

  external trim pieces which do not affect 

the operation of the 

fi

 replace may be 

removed providing they can be stored 
on or within the 

fi

 replace for re-assembly 

if the insert is removed.

 

b.

   the chimney damper may be removed 

to install the chimney liner.

Regency Inserts are constructed with the high-
est quality materials and assembled under strict 
quality control procedures that insure years of 
trouble free and reliable performance.

It is important that you read this manual thor-
oughly and fully understand the safe instal-
lation and operating procedures.  The more 
you understand the way your Regency Insert 
operates, the more enjoyment you will experi-
ence from knowing that your unit is operating 
at peak performance.

BEFORE INSTALLING

YOUR INSERT

1)

  Please read this entire manual before you 

install and use your new wood insert. Failure 
to follow instructions may result in property 
damage, bodily injury or even death. Install 
and use only in accordance with manufactur-
er’s installation and operating instructions.

2)

  Check your local building codes - Building 

Inspection Department.  You may require 
a permit before installing your insert. Be 
aware that local codes and regulations may 
override some items in the manual.

 

WARNING:  Careless installation is the 
major cause of safety hazard.  Check all 
local building and safety codes before 
installation of unit.

3)

  Notify your home insurance company that 

you plan to install a 

fi

 replace insert or hearth 

heater.

4) 

Your 

fi

 replace insert is heavy and requires 

two or more people to move it safely.  The 
insert can be badly damaged by mishan-
dling.

5)

  If your existing 

fi

 replace damper control 

will become inaccessible once you have 
installed your Regency Insert, you should 
either remove or secure it in the open posi-
tion.

6)

 Inspect your 

fi

 replace and chimney prior 

to installing your insert to determine that it 
is free from cracks, loose mortar or other 
signs of damage.  If repairs are required, 
they should be completed before installing 
your insert.  Do not remove bricks or mortar 
from your masonry 

fi

 replace.

7)

 

Do not connect the insert to a chimney 
system servicing another appliance or 
an air distribution duct.

7)

  Circulating air chambers (i.e. in a steel 

fi

 replace liner or metal heat circulator) shall 

not be blocked.

8)

  Means must be provided for removal of the 

insert to clean the chimney 

fl

 ue.

9)

  Inserts that project in front of the 

fi

 replace 

must be supplied with appropriate supporting 
means.

10)

 Installer must mechanically attach the sup-

plied label to the inside of the 

fi

 rebox of the 

fi

 replace into which the insert is installed.

In order for a solid-fuel insert to be certi

fi

 ed 

for use in factory-built 

fi

 replaces, the above 

information must be clearly stated in the instal-
lation manual and appropriate markings. Final 
approval is contingent on the authority having 
jurisdiction.

WOOD INSERT 

SPECIFICATIONS

Your 

fi

 replace opening requires the following 

minimum sizes:

 Height:   

21.5"

 Width:

    25"

 Depth:

    17"

Two faceplates are available to seal the 

fi

 replace 

opening:  

 

   Standard 

    Oversize

40" W x 30" H 

48" W x 33" H

Emissions from burning  wood or gas could 
contain chemicals known to the State of Cali-
fornia to  cause cancer, birth defects or other 
reproductive harm.

"

WARNING

: This 

fi

 replace has been converted 

for use with a wood insert only and cannot be 
used for burning wood or solid fuels unless 
all original parts have been replaced, and the 

fi

 replace re-approved by the authority having 

jurisdiction."

Содержание I2403M

Страница 1: ...ada V4G 1H4 919 051 MODELS I2403M WOOD Fireplace Insert 07 16 13 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ...ease contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be cons...

Страница 3: ...eplace 9 Installation Into a Factory Built Fireplace 9 Stainless Smoke Deflector Installation 10 Installation of the Faceplate and Trim 11 Installation of the Fan blower 12 Floor Protection 13 Firebrick Assembly 13 Draft Control 13 Flue Baffle Secondary Air Tube Installation 13 Door Handle 13 Screen Door 13 First Fire 14 OPERATING INSTRUCTIONS Some Safety Guidelines 14 Wood Storage 15 Ash Disposal...

Страница 4: ... STAINLESS STEEL LINER OPTIONAL COMPONENT FAN 142 917 ELECTRICAL RATING VOLTS 115 60 HZ 0 6 AMPS SCREEN DOOR 846 102 DANGER RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE FOR USE WITH SOLID WOOD FUEL ONLY DO...

Страница 5: ...Regency I2403M 5 DIMENSIONS 5 5 9 ...

Страница 6: ...manual before you installanduseyournewwoodinsert Failure to follow instructions may result in property damage bodily injury or even death Install anduseonlyinaccordancewithmanufactur er s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may overri...

Страница 7: ...ove it into position The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation Convection Grills The convection grills are installed before the unit is positioned inside the fireplace Positionthegrillontheinsidebodyfacesideand fastenusingthe...

Страница 8: ...ARANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below H HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLE The specified floor protector should be 3 8 18mm thick material with a K factor of 0 84 The proposed alternative is 4 100mm brick with a C factor of 1 25 over 1 8 3mm mineral board with a...

Страница 9: ...eposits in the chimney When a connected flue or liner is in use the insert is able to breathe better by allowing a greaterdrafttobecreated Thegreaterdraftcan decrease problems such as difficult start ups smoking out the door and dirty glass STEP BY STEP INSTALLATION INTO A FACTORY BUILT FIREPLACE 1 When installed in a factory built fireplace a full stainless steel rigid or flexible flue liner is m...

Страница 10: ... bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through the door openi...

Страница 11: ... The unit may now be slid into final position and attached to the connection system 5 Onceconnectionismade theinsulationstrips should be installed between the insert face plates and the fireplace face The faceplate top may now be installed with insulation stripbehind byaligningitsbracketswiththe top flange on the side shields and the angle iron bar on the insert top The faceplate trim may be insta...

Страница 12: ...attach follow the instructions provided with the fan 1 Align the fan support with the offset clip on the bottom of the ashlip 2 Slidethesupportsintotheclips Thetension holdingtheclipsinplacemaybeadjustedby increasing or decreasing the offset spacing of the clips CAUTION Label all wires prior to disconnection when servic ing controls Wiring errors can cause improper and dangerous operation WARNING ...

Страница 13: ...he air tube into the holes in the side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side as far as possible and then bring it back into the hole on the right hand side Use a pair of vise grips or pliers and tap it into place with a hammer A tighter fit will FLUE BAFFLE SECONDARY AIR TUBE INSTALLATION The flue baffle syst...

Страница 14: ... 3 Do not burn large quantities of paper in your insert 4 Ifyouhavesmokedetectors preventsmoke spillage as this may set off a false alarm 5 Donotoverfireyourinsert Iftheinsertbegin to glow you are overfiring Stop adding fuel and close the draft control Overfiring can cause extensive damage to your stove including warpage and premature steel cor rosion Overfiring will void your warranty 6 Do not pe...

Страница 15: ...esonthefluelining Whenignited this creosote can make an extremely hot fire FAN OPERATION The fan is to be operated only with the draft control rod pulled out at least 1 2 from the fully closed position The fan is not to be oper ated when the draft control rod is in the closed position pushed in The fully closed position is the low burn setting The fan unit must not be turned on until a fire has be...

Страница 16: ...hen it is cool Your local retailer can supply you with special glass cleaner if plain water and a soft cloth does not remove all deposits GLASS REPLACEMENT Your Regency Insert is supplied with 5 mm Neoceram ceramic glass Part 846 304 that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regency...

Страница 17: ...3 Regency Logo Nickel 948 216 Regency Logo Gold 48 820 482 Stainless smoke deflector 918 993 Manual Not available as a replacement part Part Description 1 850 152 Door Assy Large Gold 850 151 Door Assy Large Black 850 153 Door Assy Large Nickel Accent 850 154 Door Assy Large Gold Accent 2 846 304 Glass Replacement 4 936 243 7 8 Adhesive Tape Gasket 5 846 920 Glass Retainer Clips 8 set 6 Screw 1 4 ...

Страница 18: ...lar 287 Trim Left Regular 288 Faceplate Side Regular 289 Faceplate Top Regular 140 913 Faceplate Trim Set Oversize 180 572 Black Trim Oversize set of 3 295 Trim Right Oversize 296 Trim Top Oversize 297 Trim Left Oversize 298 Faceplate Side Oversize 299 Faceplate Top Oversize Not available as a replacement part 285 286 287 288 288 289 REGULAR 296 295 297 298 299 298 OVERSIZE ...

Страница 19: ... I2403M 19 PARTS LIST BRICK PANELS I2403M Part Description 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Partial 1 1 4 x 2 x 9 ...

Страница 20: ...20 Regency I2403M NOTES ...

Страница 21: ...Regency I2403M 21 NOTES ...

Страница 22: ...22 Regency I2403M NOTES ...

Страница 23: ... workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts requeste...

Страница 24: ..._____________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers on related products ...

Отзывы: