Regency Horizon HZO60-LP Скачать руководство пользователя страница 35

 

Regency Horizon® HZO60 Gas Fireplace

  |     

35

35

operating instructions

COPY OF LIGHTING PLATE INSTRUCTIONS

918-892a

Part #: 918-892a

Colours: Black on Grey,  except   

   

for parts indicated as being     

   

Red.

**Decal can not be any wider than cut 

line (dotted line) limited clearance.

Size:              100%

                         w- 2.4"

                         h- 16.9"

                

Jan 19/10: Created draft for approval

Feb 16/10: Changed size of decal 

        

FOR YOUR SAFETY READ BEFORE LIGHTING

A)   

This appliance is equipped with an ignition device which automatically lights the pilot. 

     Do not try to light the pilot by hand.

B)   BEFORE OPERATING

 smell all around the appliance area for gas. Be sure to smell next to 

     the fl oor because some gas is heavier than air and will settle on the fl oor.

WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electric switch, do  not use any phone in your building.

-  Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fi re department.

A)  

Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. 

       Ne pas tenter d’allumer la veilleuse manuellement. 

B) AVANT DE FAIRE FONCTIONNER L'APPAREIL

, renifl er autour de l’appareil pour déceler 

       une odeur de gaz. Renifl er près du plancher, car certains gaz sont plus lourds que l’air et 

       peuvent s’accumuler au niveau du sol.

 

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ 

:

    • Ne tentez pas d’allumer d’appareil

    • Ne touchez à aucun interrupteur; n'utilisez pas de téléphones se trouvant dans le 

      bâtiment.

    • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du 

      fournisseur.

    • Si vous ne pouvez pas rejoindre le fournisseur de gaz, appelez le service incendies.

DO NOT REMOVE 

THIS INSTRUCTION PLATE

This appliance must be installed in accordance with local codes, if any;

if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or

Natural Gas and Propane Installation Codes, CSA B149.1.

 LIGHTING INSTRUCTIONS

STOP! Read the safety information on this label.

1) 

Turn off  ON/OFF switch 

2) 

If service is to be performed - 

you must disconnect power to 

the unit, from the battery pack, 

refer to manual

1)

 

Appuyer sur le bouton ON / 

OFF 

2) 

 Pour l'entretien de l'appareil, 

vous devez débrancher 

l'appareil, du bloc-piles, voir le 

manuel d'instruction pour plus 

de détails.

1)  Turn on ON/OFF switch 

2)   After approximately 4 seconds the spark ignition system will spark 

for 60 seconds to light the main burner.

3)  The unit will turn on.

Note: The fi rst attempt to ignition will last approximately 60 seconds. 

If there is no fl ame ignition (rectifi cation) the board will stop sparking 

for approximately 35 seconds. After this wait time, the board will start 

a second try for ignition by sparking for approximately 60 seconds. 

If there is still no positive ignition after the second attempt the board 

will go into lock out.

The system will need to be reset as follows (after going      

                  

into lock out mode):

 

a)   Wait 5 minutes - turn the system off  using ON/OFF     

switch. 

b)   After approximately 2 seconds turn on ON/OFF switch.

c) Unit will repeat step 2.

CAUTION:  

H o t   w h i l e   i n 

operation.  Do  not 

t o u c h .   S e v e r e 

Burns  may  result. 

Due to high surface 

t e m p e r a t u r e s 

k e e p   c h i l d r e n , 

c l o t h i n g   a n d 

furniture,  gasoline 

and  other  liquids 

having  flammable 

vapors away. Keep 

burner  and  control 

compartment clean. 

See  installation 

a n d   o p e r a t i n g 

i n s t r u c t i o n s 

a c c o m p a n y i n g 

appliance.

WARNING: If you do not follow these instructions exactly, a fire or 

explosion may result causing property damage, personal injury or 

loss of life. Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage. Refer to the owner’s 

information manual provided with this appliance. For assistance or 

additional information consult a  qualified installer, service  agency 

or gas supplier.

AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions 

dans la présente notice risquede déclencher un incendie ou une explosion 

entraînant des dommages, des blessures ou la mort.

Une installation, d'ajustement, de modifi cation, de service ou 

d'entretien peut provoquer des blessures ou des dommages matéri-

els. Reportez-vous au manuel du propriétaire de l'information fournie 

avec cet appareil. Pour obtenir de l'aide ou des informations supplé-

mentaires consulter un installateur qualifi é, une agence de service ou 

fournisseur de gaz.

TO TURN OFF 

GAS APPLIANCE

1)  Appuyer sur l'interrupteur ON / OFF 

2)   Attendre 4 secondes. Le système d’allumage produira 

des étincelles pendant 60 secondes afi n d’amorcer le 

brûleur principal.

3)  Les fl ammes s’allumeront.

Remarque : Au premier allumage, le système tente 

d’allumer les fl ammes pendant 60 secondes. Si l’essai 

est infructueux, le système fait une pause d'environ 35 

secondes. C’est ce qu'on appelle l'étape de rectifi cation. 

Ce délai écoulé, le système tente à nouveau d'allumer 

les fl ammes en produisant des étincelles pendant 60 

secondes. Si les fl ammes ne s’allument toujours pas, le 

système se met en mode verrouillage.

 

 Il faut alors le réinitialiser en suivant les 

étapes ci-dessous (pour le déverrouiller) :

                 a)   Attendre 5 minutes et éteindre l’appareil en 

réglant l’interrupteur sur «OFF»; 

                 b)   Attendre 2 secondes et rallumer le système 

à l’aide de l’interrupteur. 

                  c)  L'unité répètera l'étape 2.

918-892a

Part #: 918-892a

Colours: Black on Grey,  except   

   

for parts indicated as being     

   

Red.

**Decal can not be any wider than cut 

line (dotted line) limited clearance.

Size:              100%

                         w- 2.4"

                         h- 16.9"

                

Jan 19/10: Created draft for approval

Feb 16/10: Changed size of decal 

        

FOR YOUR SAFETY READ BEFORE LIGHTING

A)   

This appliance is equipped with an ignition device which automatically lights the pilot. 

     Do not try to light the pilot by hand.

B)   BEFORE OPERATING

 smell all around the appliance area for gas. Be sure to smell next to 

     the fl oor because some gas is heavier than air and will settle on the fl oor.

WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electric switch, do  not use any phone in your building.

-  Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fi re department.

A)  

Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. 

       Ne pas tenter d’allumer la veilleuse manuellement. 

B) AVANT DE FAIRE FONCTIONNER L'APPAREIL

, renifl er autour de l’appareil pour déceler 

       une odeur de gaz. Renifl er près du plancher, car certains gaz sont plus lourds que l’air et 

       peuvent s’accumuler au niveau du sol.

 

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ 

:

    • Ne tentez pas d’allumer d’appareil

    • Ne touchez à aucun interrupteur; n'utilisez pas de téléphones se trouvant dans le 

      bâtiment.

    • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du 

      fournisseur.

    • Si vous ne pouvez pas rejoindre le fournisseur de gaz, appelez le service incendies.

DO NOT REMOVE 

THIS INSTRUCTION PLATE

This appliance must be installed in accordance with local codes, if any;

if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or

Natural Gas and Propane Installation Codes, CSA B149.1.

 LIGHTING INSTRUCTIONS

STOP! Read the safety information on this label.

1)  Turn off  ON/OFF switch 

2)  If service is to be performed - 

you must disconnect power to 

the unit, from the battery pack, 

refer to manual

1)

 

Appuyer sur le bouton ON / 

OFF 

2)   Pour l'entretien de l'appareil, 

vous devez débrancher 

l'appareil, du bloc-piles, voir le 

manuel d'instruction pour plus 

de détails.

1)  Turn on ON/OFF switch 

2)   After approximately 4 seconds the spark ignition system will spark 

for 60 seconds to light the main burner.

3)  The unit will turn on.

Note: The fi rst attempt to ignition will last approximately 60 seconds. 

If there is no fl ame ignition (rectifi cation) the board will stop sparking 

for approximately 35 seconds. After this wait time, the board will start 

a second try for ignition by sparking for approximately 60 seconds. 

If there is still no positive ignition after the second attempt the board 

will go into lock out.

The system will need to be reset as follows (after going      

                  

into lock out mode):

 

a)   Wait 5 minutes - turn the system off  using ON/OFF     

switch. 

b)   After approximately 2 seconds turn on ON/OFF switch.

c) Unit will repeat step 2.

CAUTION:  

H o t   w h i l e   i n 

operation.  Do  not 

t o u c h .   S e v e r e 

Burns  may  result. 

Due to high surface 

t e m p e r a t u r e s 

k e e p   c h i l d r e n , 

c l o t h i n g   a n d 

furniture,  gasoline 

and  other  liquids 

having  flammable 

vapors away. Keep 

burner and control 

compartment clean. 

See  installation 

a n d   o p e r a t i n g 

i n s t r u c t i o n s 

a c c o m p a n y i n g 

appliance.

WARNING: If you do not follow these instructions exactly, a fire or 

explosion may result causing property damage, personal injury or 

loss of life. Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage. Refer to the owner’s 

information manual provided with this appliance. For assistance or 

additional information consult a qualified installer, service agency 

or gas supplier.

AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions 

dans la présente notice risquede déclencher un incendie ou une explosion 

entraînant des dommages, des blessures ou la mort.

Une installation, d'ajustement, de modifi cation, de service ou 

d'entretien peut provoquer des blessures ou des dommages matéri-

els. Reportez-vous au manuel du propriétaire de l'information fournie 

avec cet appareil. Pour obtenir de l'aide ou des informations supplé-

mentaires consulter un installateur qualifi é, une agence de service ou 

fournisseur de gaz.

TO TURN OFF 

GAS APPLIANCE

1)  Appuyer sur l'interrupteur ON / OFF 

2)   Attendre 4 secondes. Le système d’allumage produira 

des étincelles pendant 60 secondes afi n d’amorcer le 

brûleur principal.

3)  Les fl ammes s’allumeront.

Remarque : Au premier allumage, le système tente 

d’allumer les fl ammes pendant 60 secondes. Si l’essai 

est infructueux, le système fait une pause d'environ 35 

secondes. C’est ce qu'on appelle l'étape de rectifi cation. 

Ce délai écoulé, le système tente à nouveau d'allumer 

les fl ammes en produisant des étincelles pendant 60 

secondes. Si les fl ammes ne s’allument toujours pas, le 

système se met en mode verrouillage.

 

 Il faut alors le réinitialiser en suivant les 

étapes ci-dessous (pour le déverrouiller) :

                 a)   Attendre 5 minutes et éteindre l’appareil en 

réglant l’interrupteur sur «OFF»; 

                 b)   Attendre 2 secondes et rallumer le système 

à l’aide de l’interrupteur. 

                  c)  L'unité répètera l'étape 2.

The lighting plate is located on the underside of the table top on the unit.

Содержание Horizon HZO60-LP

Страница 1: ...liance Do not try to light any appliance Extinguish any open flame If odour continues keep away from the appliance and im mediately call your gas supplier or fire department Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions Ifyoucannotreachyourgassupplier callthefiredepartment ...

Страница 2: ...l the warmth and charm of a fire at the flick of a switch The Horizon HZO60 Outdoor fireplace has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your R...

Страница 3: ...16 886 S I T Valve Description 16 Aeration Adjustment 16 Unit Assembly Prior to Installation 17 Standoff Assembly 17 Nailing Strips 17 Converting the unit from single sided to see thru 18 Drain Installation Recommended 19 Wall switch and battery installation 20 included with unit 20 Wiring Diagram 21 Optional hardwire kit installation 22 AC adaptor installation 25 Inner panel removal installation ...

Страница 4: ...k the label on the unit and if there is a difference the label on the unit is the correct one COPY OF SAFETY DECAL For the State of Massachusetts installation and repair must be done by a plumber or gas fitter licensedintheCommonwealthofMassachusetts For the State of Massachusetts flexible connec tors shall not exceed 36 inches in length For the State of Massachusetts the appliances individual man...

Страница 5: ...D 16 3 8 417 58 7 8 1495 15 1 2 394 32 1 16 814 11 1 4 286 28 7 16 723 8 203 22 9 16 573 63 5 16 1608 68 5 8 1744 60 3 8 1535 17 1 4 438 21 1 16 535 ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Страница 6: ...y Horizon HZO60 Gas Fireplace 6 dimensions UNIT DIMENSIONS HZO60 SEE THROUGH 16 3 8 417 58 7 8 1495 15 1 2 394 32 1 16 814 11 1 4 286 28 7 16 723 8 203 18 1 2 470 63 5 16 1608 68 5 8 1744 17 1 4 438 60 3 8 1535 ...

Страница 7: ... CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS FIRE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OFTHE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER YOUNG CHILDREN SHOULD BE CARE...

Страница 8: ...ing Requirements Refer to Framing Finishing section 2 Top Facing Support and Side Nailing Strips Refer to Unit Assembly Prior to Installation Section Note Must be done before installing unit into place 3 Drain Installation 4 Install ON OFF switch ensure it is in the OFF position 5 Make gas connections test for leaks 6 Install 4 AA batteries 7 Install standard and optional features Refer to the fol...

Страница 9: ...ining walls must have a fixed opening All outdoor fireplaces fire tables require total natural ventilation of 50 open space Correct Working Gas pressure is critical on E units Wherever possible avoid locating on a flat wall in a tight corner Floor space doesn t count as open area Install to the manual specs for framing and do not insulate unit or enclosure Framing enclosure must at least meet mini...

Страница 10: ...tible materials It is of the greatest importance that this fireplace be installed only in accordance with these instructions F E D A C B HZO60 External Clearance Requirements Clearance Dimension Measured From A Sidewall 11 203mm Side of Fireplace Opening B Ceiling 36 914mm Top of Fireplace Opening C Mantel Height min 22 559mm Top of Fireplace Opening D Mantel Depth max 12 304mm From Wall E Alcove ...

Страница 11: ...H Gas Connection Opening Height 2 51mm I Gas Connection Height 3 11 16 93mm J1 Gas Connection Inset 6 3 16 157mm J2 Gas Connection Inset 6 3 16 157mm K Gas Connection Opening Width 3 76mm Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible The nailing strips can be adjusted back up to 1 to allow for varying thicknesses in non combustible materia...

Страница 12: ... material thickness D Minimum Height to Combustibles Chase Enclosure 43 3 4 1111mm H Gas Connection Opening Height 2 51mm I Gas Connection Height 3 11 16 93mm J1 Gas Connection Inset 6 3 16 157mm J2 Gas Connection Inset 6 3 16 157mm K Gas Connection Opening Width 3 76mm Finished material thickness includes non combustible material tile slate etc example framing 18 1 2 if 2 thick finishing material...

Страница 13: ...L CLEARANCES SINGLE SIDED AND SEE THROUGH 2 0 12 6 4 8 10 Top of Fireplace Opening 0 14 To Unit Base 13 28 7 16 10 20 Combustible Material 2 0 12 6 4 8 10 Top of Fireplace Opening Standoff Metal Stud On Edge 0 14 Non combustible Facing 1 25mm 10 20 2 0 12 6 4 8 10 Top of Fireplace Opening 12 305mm 0 14 To Unit Base 1 25mm 22 13 10 20 12 305mm 28 7 16 22 MANTEL LEG CLEARANCES SINGLE SIDED AND SEE T...

Страница 14: ...0 Gas Fireplace 14 installation NON COMBUSTIBLE REQUIREMENTS 5 13 330mm Non combustible Material Non combustible Material 70 1 2 1791mm 127mm Combustible Material 438mm 17 1 4 5 127mm 11 1 4 286mm 60 3 8 1534mm 41 1 2 1054mm ...

Страница 15: ... able to be mounted if the finished material is beyond 1 1 2 See Step 4 if facing finishing materials will be more than 1 1 2 FRAMING FINISHING 1 Frame in the enclosure for the unit with framing material IMPORTANT The header and vertical studs must be metal Note Depending on the material used for finishing the nailing strips must be set ac cordingly so that the finished material is always at the 1...

Страница 16: ...municipalities have additional local codes it is always best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for coppe...

Страница 17: ...e standoff and the pre punched screw holes on the fireplace top line up 3 Attach the standoff securely to the unit with 2 screws per standoff on opposite corners Standoffs installed Nailing Strip Nailing Area Note Depending on the material used for finishing the nailing strips must be set accordingly so that the finished material is always at the 1 1 2 edge of the flange NAILING STRIPS The nailing...

Страница 18: ... in locations shown below retain these screws and replace after back firebox panel is removed 5 Reinstall bottom access panel burner tray burner cap and inner panels side only 6 Remove 2 back standoffs by removing 4 screws on each side recycle standoffs 7 Install 2nd supplied nailing strip to unit with 3 screws 8 Proceed with framing and installation instructions to complete install tooltip Burner...

Страница 19: ...move 4 screws to remove the rear access panel from the back of the unit this will allow access to the drain hole at the base of the unit 2 On the exposed drain hole see location below install a PVC 3 4 threaded coupling reducer going from the top of the pan down through the hole Apply a silicone based sealant around the base and threads before installation 3 Holding the reducer coupling with a wre...

Страница 20: ...wire and battery extension wire through the strain relief 5 Connect low voltage wire to supplied switch fasten switch to right side of electrical box polarity not important 8 Place supplied gasket on top of electrical box 9 Fasten cover to electrical box using supplied screws 10 Place switch in OFF position until final installation is complete Center knock out Strain Relief 6 Install supplied 4 AA...

Страница 21: ...This appliance does not require a 120V A C supply for operation NOTE 4 AA batteries must be installed in the battery pack to operate the burner switch Do not use a 9 volt battery 0 886 001 Proflame Valve Standard Main On Off Switch or Optional Wall Switch 1 of 10 Optional ...

Страница 22: ...into the outer box with 4 screws Diagram 1 2 Depending on which side or conduit size the electrical outlet will be installed remove the corresponding knockouts in the outer box and electrical box to allow access for the conduit wiring supplied by others Diagram 1 ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN QRFNRXWV 2XWHUER OHFWULFDO R URPPHW H KROH In the diagram below the outer box is in...

Страница 23: ...Adaptor Install in the manual 6 Run the AC adaptor wire from the recently installed electrical box to the back of the unit end 7 Attach the AC adaptor to the DC supply wire Secure wire using a strain relief see enclosed picture Reinstall the valve cover plate reverse Step 6 Valve cover plate PTO30 PTO50 HZO60 only Strain Relief Protective cover with lid Outer cover Back of unit housing 13 Install ...

Страница 24: ...e outer box to studs Studs to secure outerbox 16 Installing the outer box into conventional framing The front outer cover may also be covered with finishing materials if desired Ensure that the outer cover when using finished materials that it may be removed if access is ever required to the GFI circuit Additional studs should be placed anywhere in this area to be able to secure finished materials Fr...

Страница 25: ...al codes if hard wired In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States The 4 AA batteries do not need to be installed if using the AC adaptor The batteries would only be required in the event that 120V power is lost Important Electrical box must be located within 10 feet of the burn...

Страница 26: ...rmal and should not be considered a defect All hand and finger marks MUST be cleaned off with a soft cloth and a stainless steel cleaner Most stainless steel cleaners leave a film residue on the surface of the panels Use an ammonia based cleaner ie glass cleaner to remove this film before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to ...

Страница 27: ... of glass crystals beads or stones can alter the unit s performance any damage caused by the use of any unapproved glass or stones will not be covered under warranty When using Basalt Volcanic Stones DO NOT cover pilot light that lead to pilot flame 1 Start pouring Crystals Firebeads on one end of the burner 2 Work Crystals Firebeads to other end of the Burner Base and burner tube should not be vi...

Страница 28: ...wig C Log Twig D Log Twig E Log Twig F Diagram 3 Diagram 2 A A 2 Install Log Twig A on the left side of the burner orient the Log Twig on the left side of the burner to mirror Log A on the right as shown in Diagram 3 1 Install Log Twig A on the right side of the burner orient the Log Twig in the same way and in a similar location on the right side of the burner as shown in Diagram 2 3 Install Log ...

Страница 29: ... 5 Install Log Twig E on the left side of the burner orient Log Twig E across Log Twig D in the same way and in a similar position as shown in Diagram 6 7 Install Log Twig B on the left side orient Log Twig B in the same way and in a similar position as shown in Diagram 8 Diagram 7 Diagram 6 Diagram 8 E E 4 Install Log Twig D on the right side of the burner orient Log Twig D to mirror Log D instal...

Страница 30: ...m 10 Diagram 11 Diagram 12 9 Install Log Twig C on the left side of the burner orient Log Twig C in the same way and in a similar position as shown in Diagram 10 10 Install the opposite Log Twig C on the right side of the burner orient Log Twig C in the same way and in a similar position as shown in Diagram 11 mirror Log C as installed on the left side 11 Install Log Twig F on the left side of the...

Страница 31: ...IES 919 764 03 06 17 F 12 Install the opposite Log Twig F on the right side of the burner orient Log Twig F in the same way and in a similar position as shown in Diagram 13 mirror Log F as installed on the left side 13 Completed install shown below Diagram 13 Diagram 14 ...

Страница 32: ...te line up the tabs on the faceplate with the C shaped openings on the left and right sides of the unit There are 3 slots on each tab so the faceplate to accommodate different finishing materials 2 Install logo onto faceplate 4 To remove reverse steps 3 For installations where thicker finishing material is used the optional trim piece may be installed to fill the gap Install the trim between the b...

Страница 33: ...ot the glass pieces x2 into the space between the burner tray cover and the bottom access panel NOTE If setting unit up as a see through repeat procedure on opposite side of burner GLASS WIND SHIELD INSTALLATION Bottom Access panel Burner Tray Cover Glass Wind Shield Glass Wind Shield Installed ...

Страница 34: ... condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up OPERATING INSTRUCTIONS 1 Read and understand these instructions before operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Ensure that the stainless panels are installed 5 Verify log pl...

Страница 35: ...ges des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matéri els Reportez vous au manuel du propriétaire de l information fournie avec cet appareil Pour obtenir de l aide ou des informations supplé mentaires consulter un installateur qualifié une agence de service ou fournisseur de gaz 918 892a xcept ng er ...

Страница 36: ...eat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove 4 The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint Regency uses StoveBright Paint Metallic Black 6309 5 Make a periodic check of burner for proper position and condition Visually check the flame of the burner periodically making sure the...

Страница 37: ...aceplate by lifting it up and off the unit 7 Remove the pilot shield 8 Remove any media glass etc and log set if installed 9 Locate and remove 22 screws to remove the burner tray 13 Ensure gas supply is OFF and remove flex connection at valve 14 Remove orange EV1 wire and ground wire connected to the gas valve 15 Remove green EV2 wire connected to the gas valve 10 Lift burner tray off 11 Remove 2 ...

Страница 38: ...ft valve assembly up and out 18 Remove both yellow green ground wires from valve and valve bracket 19 Replace valve assembly gasket if necessary 20 Rotate HI LO modulating valve all the way to the left for HI position 21 Install new valve assembly and reverse steps 11 1 22 Test gas connections for leaks ...

Страница 39: ... 126 Side Standoff 17 646 910 Faceplate 18 646 117 F Stainless Side Panel 19 646 116 F Burner tray cover 20 646 115 Stainless cover plate 21 326 034 Panel Clip 22 See next page 23 940 488 P Front Glass 26 646 114 Stainless Back Panel 27 646 113 Rear Panel 646 125 Rear Panel Bracket 646 108 Glass Clip Part Not Shown 16 20 ...

Страница 40: ...86 SIT 907 014 N S 910 100 Orifice SIT Pilot NG 62 977 166 N S 910 101 Orifice SIT Pilot LP 35 977 168 N S 911 013 Valve Wiring Harness With IPI CPI Switch 0 584 912 N S 911 019 On Off Switch Wire N S 911 086 Wire 9 Volt Battery Extension N S 904 529 Allen Key 5 32 Long N S 260350 Valve Gasket Silicone Sponge Sold Per Foot 8 Feet Required N S 908 529 Label Natural Gas N S 908 528 Label Propane Red...

Страница 41: ...Regency Horizon HZO60 Gas Fireplace 41 41 parts list 16 15 14 13 12 11 3 17 30 10 21 N A 24 20 25 19 17 22 9 1 N A 26 20 ...

Страница 42: ...rranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre approved and assigned agent provided that the defective part is returned to the distributor dealer or agent for inspection if requested by FPI Alternatively FPI may at its own discretion fully discharge all of its obligations under the warranty by refunding the verified purc...

Страница 43: ... regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are not covered under the terms of this Limited Warranty FPI has no obligation to enhance or modify any unit once manufactured i e as products evolve field modifications or upgrades will not...

Страница 44: ...cal provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem ...

Страница 45: ... in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases m...

Страница 46: ......

Страница 47: ......

Страница 48: ...ion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _________________________________________...

Отзывы: