background image

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

920-084

MODEL:    HI2450

Hampton™

HI2450 Wood

Fireplace

Insert

08.20.19

Owners & Installation Manual

Installer

: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

www.regency-fire.com

French Manual: http://ow.ly/Zvzjy

Manuel en Français: http://ow.ly/Zvzjy

0219WN026S

Tested & listed by:

Содержание Hampton HI2450

Страница 1: ...replace Insert 08 20 19 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com French Manual http ow ly Zvzjy Manuel en Français http ow ly Zvzjy 0219WN026S Tested listed by ...

Страница 2: ... in a manner inconsistent with operating instructions in this manual or if elements are deactivated or removed CAUTION BURNUNTREATEDWOODONLY OTHERMATERIALSSUCHASWOODPRESERVATIVES METALFOILS COAL PLASTIC GARBAGE SULPHUR OR OIL MAY DAMAGE THE HEATER This heater is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hard woods as...

Страница 3: ... Flue collar removal and Installation Floor Protection 24 Flue Baffle Secondary Air Tube Installation 24 Brick Installation 25 Seasoned wood 26 operation Operating Instructions 27 Draft Control 27 First Fire 27 Fan Operation 28 Ash Disposal 28 Safety Guidelines and Warnings 28 maintenance Maintenance 29 Creosote 29 Door Gasket 29 Glass Maintenance 29 Wood Storage 29 Door Gasket 31 Glass Cleaning 3...

Страница 4: ...OIS SOLIDE NE PAS SURÉLEVER LES BÛCHES NI LES PLACER SUR DES GRILLES MAIS LES DÉPOSER DIRECTEMENT SUR L ÂTRE RISQUE DE DÉGAGEMENT DE FUMÉE OU DE FLAMMES TOUJOURS GARDER LES PORTES COMPLÈTEMENT OUVERTES OU FERMÉES LORSQUE L APPAREIL FONCTIONNE DANS UNE MAI SON MOBILE TOUJOURS GARDER LES PORTES BIEN FERMÉES LORSQUE L APPAREIL FONCTIONNE OUVRIR LA PORTE UNIQUEMENT POUR ALIMENTER LE FEU SI LES PORTES ...

Страница 5: ... 440mm 23 1 4 591mm 11 3 8 290mm 31 1 2 800mm 21 5 8 548mm 9 3 4 246mm 21 5 8 548mm 6 3 8 161mm 11 1 4 286mm dimensions with regular faceplate ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Страница 6: ...HI2450M 6 dimensions 51 7 8 1318mm 34 1 2 876mm 48 3 8 1229mm 16 1 8 411mm 23 1 4 591mm 12 1 2 318mm 31 1 2 800mm 21 5 8 548mm 13 7 8 353mm 21 5 8 548mm 7 1 4 186mm 10 1 8 257mm dimensions with oversize faceplate ...

Страница 7: ...ailure to follow instructions may result in property damage bodily injury or even death Install and use only in accordance with manufac turer sinstallationandoperatinginstructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless ins...

Страница 8: ... that your floor protection and hearth will meet the standards for clear ance to combustibles Your hearth extension must be made from a non combustible material Extending 16 for US and 18 for Canada measured from the fuel loading door Clearances are critical Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is used on the mantel and the faci...

Страница 9: ...it out at least 3 to 4 inches in order to make the necessary flue connections and to install the faceplate Be sure to protect your hearth extension during the installation ie with a heavy blanket Door Hinges DO NOT LIFT UNIT FROM THESE PARTS Installing Your Insert WARNING DO NOT LIFT OR PUSH THE UNIT FROM THE ASH LIP LEFT SIDE CAST or RIGHT SIDE CAST THE CASTING WILL CHIP OR BREAK STOP PLEASE READ...

Страница 10: ...alledinafactorybuiltfireplace afullstainlesssteelrigidorflexible flue liner is mandatory for both safety and performance purposes When a flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created The greater draft can decrease problems such as difficult start ups smoking out the door and dirty glass 2 In order to position the flue liner the existing rain...

Страница 11: ...h bolts and slide deflector upward and out Install new deflector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through the door o...

Страница 12: ...cally while each side rests on the hearth Secure using 1 bolt per bracket Side Mounting Bracket Mounting Hole Right Side Faceplate Left Side Faceplate 3 Place Mantel Top onto the top of the firebox Mantel Top Right Side Cast With the Mantel Top in place check to make sure there is no gap between the nut retainer and the underside cast of the Mantel Top If there is a gap present you will need to lo...

Страница 13: ...stment bolts Cast mounting bolts for height adustment Right Side Faceplate Left Side Faceplate 7 Carefully slide the Mantel Top back into position See Step 3 to identify side casts See next page for recommended measurements Slide Mantel Top back 6 If unable to align side faceplate to unit and top faceplate further adjustments need to be made complete one side at a time Loosen all bolts on brackets...

Страница 14: ...ENDED MEASUREMENTS FOR SETTING SIDE CASTS Stop Read Carefully Enamel Cast components are very fragile Use extreme care when handling Right Side Cast Left Side Cast 1 4 approx between both sides of door and cast Ashlip 1 8 1 4 approx for both sides betweenashlipandbottomofsidecast 4 1 2 4 3 4 boths sides rear inside edge to firebox Important Verify gap between cast and door did not change when rear...

Страница 15: ...each side rests on the hearth Secure using 2 bolts per bracket Side Mounting Bracket Mounting Hole Right Side Face plate Left Side Face plate 3 Place 1 4 x 1 Hex head bolt with 2 washers in Mantel Top Spacer locations shown below 4 Place Mantel Top onto the top of the firebox Mantel Top Mantel Top Spacer Right Side Cast With the Mantel Top in place check to make sure there is no gap between the Ma...

Страница 16: ...ire 2 people it is heavy and awkward to handle Retainer Mounting Plates Gasket Location Top Faceplate Right Side Face plate Left Side Faceplate 8 Carefully slide the Mantel Top back into position Slide Mantel Top back 9 Adjust Left Side Faceplate and tighten bolts Repeat step for Right Side Faceplate 10 Location of Insulation a Place 1 piece of Insulation behind the Mantel Top b Cut the second pie...

Страница 17: ...in place and tighten all bolts If side cast height needs adjusting loosen 2 bolts holding cast bracket and adjust up or down Rear View of Unit RECOMMENDED MEASUREMENTS FOR SETTING SIDE CASTS SIDE CAST ADJUSTMENTS Stop Read Carefully Enamel Cast components are very fragile Use extreme care when handling Right Side Cast Left Side Cast 1 4 approx between both sides of door and cast Ashlip 1 8 1 4 app...

Страница 18: ...the door make sure that the glass gasketing on the left and right bracket is facing you 4 Carefully place the glass black strip up into the bottom re tainer Keeping it in place re install the sides and top retainer and bolts Do not tighten bolts finger tight only 5 Lift the bottom of the glass upwards till it stops secure glass retainer using the 8 bolts Do not wrench down on the bolts as this may...

Страница 19: ...a has been assembled carefully slide the Fan into position by centering the Fan below the Ashlip and align the Fan Support Clips with the Offset Clips under the Ashlip Note The Draft Control Rod is to fit through the top open ing in the Switch Plate IMPORTANT Ensure that the Left and Right Side Fan Facia do not hit the sides of the Faceplate when sliding the Fan into position as the casting may ch...

Страница 20: ... wire and thermodisc assembly from the left side and relocate to the right side of the main fan housing See step 10 for Thermodisc Assembly installation Important Note Thewireharnessmaybetightbetweenthefanmotor and main body but will move over and down to the base with a little flexing of the fan motor Ensure the wire harness rests on the base when pulled over 6 Remove the 2x 7 16 bolts from the r...

Страница 21: ...y base See Diagram 1 11 Attach the new cover plate to the left side casting us ing 2x 6 32x3 8 Pan Head Phillips black screws Thermodisc Assembly 9 Remove the wires one at a time from the existing switch plate and attach each wire to the new switch plate each wire in the same position as it was on the old switch plate see wiring diagram Discard the old switch plate Switch Plate Left Cover Plate Di...

Страница 22: ...the side walls 6 Manoeuver the baffle above the air tube and slide out Side View Front View Front View 5 Lift the left baffle out from underneath the right baffle then lift out Remove the right baffle Note F2500 shown 7 Takea ratchetandremovethetwoboltsatbackinsideofthefirebox These bolts are used to secure the flue collar Keep these and washers for re install 8 Slide collar off the unit List of T...

Страница 23: ... into place pull on the rod to ensure that the flue adaptor is properly engaged See Diagram 5 Double check the adaptor is seated properly and the pull rod in the firebox locate the two holes lined up to the two holes on the adaptor 14 Use the two bolts washers and lock washers supplied in manual pack and install them tighten down using the 1 2 socket to ensure the adapter is positively secured to ...

Страница 24: ...s they can be dislodged if too much fuel is forced into the firebox The unit arrives with the 2 baffles and 2 air tubes on the floor of the firebox 1 Open the door and remove stainless steel smoke deflector See smoke deflector instruc tions in this manual Smoke deflector 2 Slide the left baffle over the 2 remaining air tubes from the front and then push it to the back Side View 4 Install the 2 fro...

Страница 25: ...f your stove and radiate heat more evenly Check to see that all firebricks are in their correct positions and have not become misaligned during shipping Install all firebricks if bricks were removed at install per the diagram below and place in their correct positions Do not use a grate 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1...

Страница 26: ...ods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicators as possi...

Страница 27: ...en warmed Always build up the fire slowly 4 For the first few days the stove will give off an odour from the paint This is to be expected as thehightemperaturepaintbecomesseasoned Windows and or doors should be left open to provide adequate ventilation while this tem porary condition exists Burning the stove at a very high temperature the first few times may damage the paint Burn fires at a modera...

Страница 28: ...sofpaper garbage and never burn flammable fluids such as gasoline naptha or engine oil in your stove 4 If you have smoke detectors prevent smoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney connector flue baffle or the stove top begin to glow you are over firing Stop adding fuel and close the draft control Over firing can cause extensive damage to your stove i...

Страница 29: ...efully maintain your fire place stove including burning seasoned wood and maintainingacleanstoveandchimneysystem Have the chimney cleaned before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require no lubrication 5 The chimney and chimney connector should be inspectedatleastonceeverytwomonthsduring the heating season to ...

Страница 30: ...DS SUCH AS GASOLINE NAPTHA OR ENGINE OIL SOME FUELS COULD GENER ATE CARBON MONOXIDE AND ARE VERY DANGEROUS DO NOT BURN Treated wood Coal Garbage Cardboard Solvents Colored Paper Trash Salt drift wood Cut lumber plywood mill ends Burning treated wood garbage solvents colored paper or trash may result in release of toxic fumes Burning coal cardboard or loose paper can produce soot or large flakes of...

Страница 31: ... glass retainer back on Ensure that it rests on the gasket and not the glass 6 Secureglassretainerusingthe8screws Donot wrench down on the glass as this may cause the glass to break Handle Replacement 1 Removehandlebyunscrewingitfromthelatch 2 Fit new door handle over latch and screw it in to place Door Removal Whenhandlingenamelparts pleasehandle with care as they can be damaged 1 RemovetheTopFac...

Страница 32: ...emove the Latch from the Mounting Bracket by undoing the inner 2 bolts L a t c h Assembly L a t c h A s s e m b l y removed from unit 3 RemovenecessaryamountofspacerssittingontheMountingBracket Ensure an equal amount of spacers are removed from both top and bottom M o u n t i n g Bracket Latch 4 Re secure Latch to Mounting Bracket using 2 bolts M o u n t i n g Bracket Spacers Latch Assembly re ass...

Страница 33: ...paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti seize lube ie never seize Check glass for cracks Replace if required Clean blower motor Disconnect power supply Remove and clean blower DO NOT LUBRICATE Inspect and clean chimney Annual professional ch...

Страница 34: ...e baffles as per page 24 2 Loosen the two 7 16 bolts nuts to remove replace vertical baffle 3 Repeat steps to install new vertical deflector NOTE ENSURE BAFFLE IS PUSHED UP AS FAR AS POSSIBLE TIGHT TO TOP OF FIREBOX 7 16 Nuts 7 16 Bolts Vertical Deflector Remove 2 front air tubes Slide left down to remove Reverse to replace ...

Страница 35: ...oor Gasket Kit 24 Glass Retainer 936 238 Glass Gasket sold per ft 36 033 953 Air Tube 3 4 Qty 4 37 020 957 Baffle 2 set 38 181 019 Smoke Deflector 40 910 157 P Fan Motor Only 41 021 022 Firebox Floor Gasket 42 181 632 P Flue Adaptor Not Shown in the drawing 300 981 Cast Grill 181 039 Wood Damper Handle 910 142 Fan Thermodisc 910 138 2 Way Switch 910 140 3 Way Switch 948 220 Hampton Logo Plate 910 ...

Страница 36: ...s list Standard Cast Faceplate Part Description 300 921 Cast Faceplate Metallic Black 300 925 Cast Faceplate Timberline Brown 200 Top Faceplate 201 Left Side Faceplate 202 Right Side Faceplate Not available as a replacement part ...

Страница 37: ...t Faceplate Metallic Black 300 975 Cast Faceplate Timberline Brown 300 Top Faceplate 301 Left Side Faceplate 302 Right Side Faceplate 303 300 060 Mounting Plate LH 305 300 061 Mounting Plate RH Not Shown in the Drawing 300 005 Top Retainer Not available as a replacement part 300 301 302 305 303 ...

Страница 38: ...y HI2450M 38 parts list Brick Panels HI2450 Part Description 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Partial 1 1 4 x 2 x 9 ...

Страница 39: ...Regency HI2450M 39 39 notes ...

Страница 40: ...Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s opt...

Страница 41: ... chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs kiln dried wood lack of regular maintenance...

Страница 42: ...he above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain all warranty and service In the event the authorized selling dealer is unable to provide w...

Страница 43: ...r us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANAD...

Страница 44: ...44 Regency HI2450M 44 notes ...

Страница 45: ...Regency HI2450M 45 45 notes ...

Страница 46: ...46 Regency HI2450M 46 notes ...

Страница 47: ......

Страница 48: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _______________________________________...