Cool Wall Install (Combustible Finishing)

Standard Install (Non-Combustible Finishing)

Clean Front

Standard Install: 
• Non-vented chase
• Non-combustible board required
• Combustible framing

Cool Wall Install: 
• Vented chase
• Combustible material can be used all around the fireplace
• Combustible framing

Clean Front

Clean Front

Outside Finish w/ Finishing Trim

Outside Finish w/ Faceplate

Grandview® G800EC Gas Fireplace | P. 3

Содержание Grandview G800EC Series

Страница 1: ...put Altitude 0 4500 ft 0 1372m 27 000 BTU h 8 33 kW 25 500 BTU h 8 33 kW Vent Sizing 4 Inner 6 5 8 Outer 4 Inner 6 5 8 Outer 42 7 8 1088mm 35 7 8 913mm OUTSIDE FINISH 30 7 8 783mm CLEAN FRONT 32 5 8 827mm CLEAN FRONT 1 5 8 41mm 33 7 8 862mm OUTSIDE FINISH 1 5 8 41mm 29 7 8 759mm 25 1 2 648mm 36 3 8 924mm 35 1 8 892mm 18 7 8 480mm 17 1 2 446mm 7 1 2 192mm 1 1 2 39mm 28 7 8 734mm 11 1 4 287mm 11 1 4...

Страница 2: ... to the edge of the fireplace or with either a finishing trim or faceplate See descriptive diagrams on the next page Cool Wall Clearances 4 Cool Wall Mantel Clearances 5 Cool Wall Mantel Leg Clearances 5 Cool Wall Application Framing 6 Chase Vent Installation 7 Clean Front Installation Clearances 8 Clean Front Installation Mantel Clearances 9 Clean Front Installation Mantel Leg Clearances 10 Non C...

Страница 3: ...d Install Non vented chase Non combustible board required Combustible framing Cool Wall Install Vented chase Combustible material can be used all around the fireplace Combustible framing Clean Front Clean Front Outside Finish w Finishing Trim Outside Finish w Faceplate Grandview G800EC Gas Fireplace P 3 ...

Страница 4: ... Measured From A Mantel Height min 0 0mm Top of Fireplace Opening B Sidewall 6 152mm Side of Fireplace Opening C Ceiling 47 1 2 1207mm Top of Fireplace Opening D Mantel Depth max 14 356mm Front of Fireplace Opening E Alcove Width 84 2134mm Wall to Wall Minimum F Alcove Depth 36 914mm Front to Back Wall Maximum G Convection Air Outlet 66 sq Top Front of Enclosure H Convection Air Outlet Opening Off...

Страница 5: ...ce Opening 32 1 2 826mm 10 254mm 5 127mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening A B 14 To Floor 10 Inches 5 C 2 7 14 Mantel leg Allowable mantel leg projection TopView Side opening of fireplace Mantel leg Mantel leg 2 51mm 3 76mm 1 3 4 44mm 32 1 2 826mm overall fireplace width Cool Wall Mantel Leg Clearances See framing dimensions on next page Note If Faceplate or F...

Страница 6: ...nt Centerline Height Rear 29 737mm S Top Vent Vent Centerline Height Top 44 1118mm T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 6 3 8 162mm V Gas Connection Width 3 76mm W Clearance to Corner of Unit 2 3 4 70mm Important Framing height requires consideration of the hearth depth Dimension N N the thickness of the installed hearth Q P R M N O S S U T V Combustible header Top Vent Rear V...

Страница 7: ...vent The top of the Chase vent opening must be 1 5 or less from the top of the chase enclosure Fasten the Chase vent with screws and construction adhesive If the chase vent is not being used a minimum 66in2 opening in the enclosure is required to maintain safe operating tempera tures This can be achieved in a number of ways including a reveal at the top of the chase Grandview G800EC Gas Fireplace ...

Страница 8: ...aintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles G800EC Clearance Requirements Clearance Dimension Measured From A Mantel Height min 11 1 2 292mm Top of Fireplace Opening B Sidewall 25 635mm Side of Fireplace Opening C Ce...

Страница 9: ...Ensure the paint that is used on the mantel and the facing is High Quality or the paint may discolour Mantel Clearances G800EC A B C D From Top of Fireplace Opening 32 1 2 826mm 20 1 2 597mm 15 1 4 470mm 11 1 2 292mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 19 7 12 A B 14 To Floor 12 24 Inches C D Non Combustible Material Min 11 1 2 H 292mm 16 18 Material Min 2 D 51...

Страница 10: ...ERIAL IN THIS AREA No Combustible Materials in this Area 37 1 2 953mm 11 1 2 292mm 3 76mm 3 76mm 30 7 8 784mm 1 5 8 41mm See framing dimensions on next page Allowable mantel leg projection TopView Side opening of fireplace Mantel Mantel leg 38mm 4 1 4 108mm Leg 3 76mm 6 7 8 175mm 32 1 2 826mm Overall Fireplace width 1 1 2 2 38mm 51mm Grandview G800EC Gas Fireplace P 10 ...

Страница 11: ...ight Rear 29 673mm S Top Vent Vent Centerline Height Top 44 1118mm T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 6 3 8 162mm V Gas Connection Width 3 76mm W Clearance to corner of unit 2 3 4 70mm Non combustible Height 11 1 2 292mm Important Framing height requires consideration of the hearth depth Dimension N N the thickness of the installed hearth S S U T V Q P M N O Combustible head...

Страница 12: ...m Optional Clean Front Trim Install Instructions 1 Loosen the four 4 screws that secure the left and right nailing flanges to the unit 2 Slide the left and right tiling flanges onto the front of the fireplace Use the slots to center with the screw securing the Nailing Flanges 3 Tighten screws down 4 Slide the Bottom Tiling Flange against thebottomofthefireplace Securewith a screw on each side 5 Fi...

Страница 13: ...uired clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles G800EC Outside Finish Clearance Requirements Clearance Dimension Measured From A Mantel Height min 10 254mm Top of Fireplace Opening B Sidewall 25 635mm one side only Side of Fireplac...

Страница 14: ... Fireplace Opening 34 754mm 19 483mm 15 381mm 10 254mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace 12 1 7 A B 14 To Floor 12 24 Inches C D Non Combustible Material Min 10 H 254mm 9 Outside Finish Installation non Cool Wall Mantel Leg Clearances Allowable mantel leg projection TopView Side opening of fireplace Mantel Mantel leg 38mm 4 1 4 108mm Leg 3 76mm 6 7 8 175mm 32 1 2 826m...

Страница 15: ... Vent Centerline Height Rear 29 673mm S Top Vent Vent Centerline Height Top 44 1118mm T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 6 3 8 162mm V Gas Connection Width 3 76mm W Clearance to Corner of Unit 2 3 4 70mm Non combustible Height 10 254mm Important Framing height requires consideration of the hearth depth Dimension N N the thickness of the installed hearth S S U T V Q P M N O C...

Страница 16: ...gth of 3ft 0 9m Note Must use optional rigid pipe adaptor Part 510 994 when using Rigid Pipe vent systems Maintain clearance to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall 2 0 12 6 4 8 10 2 0 6 4 8 Vertical Height Feet Rigid 44 1 1m Horizontal Feet Max 36 0 9m Flex 44 1 1m 18 0 5m 3 Top Vented Factory Se...

Страница 17: ...ations using FPI venting systems as well as Simpson Dura Vent Direct Vent Ameri can Metal Products Olympia Ventis DV Security Secure Vent AmeriVent Direct Vent AstroCapTM is the proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product has been evaluated by Intertek for using a R...

Страница 18: ...nal rigid pipe adaptor Part 510 994 when using Rigid Pipe venting systems All Rigid Pipe Systems 4 inner diameter 6 5 8 outer diameter FPI Flex Vent 4 inner diameter 6 7 8 inner diameter Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the terminatio...

Страница 19: ...ystem and vertical flex kit to same limitations Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbows with rigid pipe vent systems for Propane and Natural Gas 2 0 6 10 4 8 12 Vertical Height Feet Horizontal Feet 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 0 2 4 6 Minimum Height Requiremen...

Страница 20: ...Lengths do not include elbow indicated Horizontal terminations Three 3 90o Elbows Lengths do not include elbow indicated One 90o elbow Two 45o elbows Option V H V V1 H H1 With these options max total pipe length is 30 feet with min of 12 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90o elbowsisrequired A 0 Min 1 Max 1 Min 2 Max B 1 Min 2 Max 3 Min 3 Max C 2 Mi...

Страница 21: ...Min 7 Max 6 Min F 5 Min 8 Max 7 Min Lengths do not include elbow indicated Required when using rigid venting One 90o elbow Two 45o elbows Option V H H1 V V1 With these options maximumtotalpipelength is 30 feet with minimum of 10 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 0 Min 2 Max 2 Min B 1 Min 2 Max 3 Min C 2 Min 3 Max 4 M...

Страница 22: ...Min 6 Max 8 Min G 6 Min 7 Max 9 Min H 7 Min 8 Max 10 Min With these options max total pipe length is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required One 90o elbow Two 45o elbows Lengths do not include elbow indicated No Vent Restrictor Installed Required when using rigid venting Grandview G800EC Gas Fireplace P 22 ...

Отзывы: