Clearances

Unless otherwise stated the clearances listed below are Minimum 
distances to combustible materials.  

Please Note: A major cause 

of chimney related fi res is due to a failure to maintain required 
clearances (air space) to combustible materials. It is of the greatest 
importance that this fi replace and vent system be installed only in 
accordance with these instructions.

Combustible Mantels

Because of the extreme heat this fi replace emits, the mantel 
clearances are critical.

 Combustible mantel clearances from top of 

the louvers are shown in the diagram below. Mantel may be installed 
anywhere in the shaded area or higher.

Note:  A non-combustible mantel may be installed at a lower 

height.

Note:  Ensure the paint that is used on the mantel and the facing 

is “heat resistant” or the paint may discolour.

Clearances to Combustibles

Dimension

Description

E33

A*

From Unit to Side Walls

8” (203mm)

B

From Unit to Ceiling

47” (1194mm)

C

Minimum Mantel Height 

15” (381mm)

D

Maximum Mantel Depth

12” (305mm)

E

Alcove Width

76” (1930mm)

F

Alcove Depth

36” (914mm)

G

Hearth Height

1-¼” (32mm)

H

Hearth Width

45-½” (1156mm)

I

Hearth Depth

13” (330mm)

* Alcove side wall must have a minimum of 8” (203mm) clearance on one side.

25" (635mm)

to floor

Side View

12" (305mm) Mantel

3-1/2" (89mm) Mantel

20”

(508mm)

47”

(1194mm)

to ceiling

15”

(381mm)

2

0

12

6

4

8

10

2

0

12

6

16

4

14

8

18

20

10

Top of

Unit

Flush Front Mantel Clearances

Full Screen Door Mantel Clearances

E33 Gas Insert

D

128

June 2007 Regency Product Specifi cations Book

Gas Inser

ts

Gas Inserts