Regency Gas Insert E21-LP3 Скачать руководство пользователя страница 25

 Regency

®

 E21-3 Gas Fireplace Insert

25

INSTALLATION

FULL SCREEN DOORS

1)

  Hold the full screen door up against the unit in order to make the 

following wire connections.

 

Pull the ON/OFF connector wires thru the box and connect them to 
the switch.

 

Connect the fan switch wires with the wire connectors from the fan 
speed control. Place clips over wires and tuck into side trim. 

2)

  Lift the unit up slightly and push down on the corners of the Bottom 

Trim Bracket and slide under unit.

Bottom Trim 

Bracket

Push in Corners

3)

  Completely secure full screen door to the unit by securing 4 screws 

to the Left and Right Side Trim.

4) 

Secure the Top Frame by sliding it on the screws at the top of the full 
screen door. It is held in place by magnets.

Top Frame

Screw

Содержание Gas Insert E21-LP3

Страница 1: ... try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 918 671c MODELS E21 NG3 Natural Gas E21 LP3 Propane E21 ...

Страница 2: ...ou with all the warmth and charm of a fireplace at the flick of a switch The models E21 NG3 and E21 LP3 of this series have been approved by Warnock Hersey for safety As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Rege...

Страница 3: ...Regency E21 3 Gas Fireplace Insert 3 INSTALLATION 40 1 8 22 11 16 Low Profile Faceplate Dimensions 9 7 8 51 Standard size shown custom size also available ...

Страница 4: ...16 Faceplate Trim Installation 20 Flush Glass 21 Flush Louvers 21 Optional Bay Front 22 Bay Louvers 22 Conversion from NG to LP 23 Full Screen doors 26 Low profile faceplate installation 28 Low profile hearth trim installation 30 Remote Control 31 Wall Switch 31 Wall Thermostat 31 Final Check 32 OPERATING INSTRUCTIONS Operating Instructions 32 Lighting Procedure 32 Shutdown Procedure 32 First Fire...

Страница 5: ...e low 1 1 WC C E 0 27 kPa 2 9 WC C E 0 72 kPa Pression tublure d échappement basse Altitude 0 2000 ft 2000 4500 ft 0 4500 ft L altitude 0 610m 610 1372m 0 1372m Orifi ce size 43 DMS 44 DMS 54 DMS Grandeur de l injecteur Maximum input 23 500 Btu h 22 000 Btu h 22 500 Btu h Debit calorifi que maximum Minimum input 11 750 Btu h 11 000 Btu h 11 250 Btu h Debit calorifi que minimum Duplicate Serial No ...

Страница 6: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspectio...

Страница 7: ...ICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC ITISIMPERATIVETHAT CONTROLCOMPARTMENTS BURNERS ANDCIRCULATINGAIRPASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY...

Страница 8: ...approved for installation into a mobile home 9 Inspect the venting system annually for block age and any signs of deterioration 10 Any safety glass removed for servicing must be replaced prior to operating the appliance 11 To prevent injury do not allow anyone who is unfamiliarwiththeoperationtousethefireplace insert 12 Wear gloves and safety glasses for protection while doing required maintenance...

Страница 9: ...all the Regency gas fireplace insert INSTALLATION CHECKLIST 1 Locate your appliance Refer to the Clear ances to Combustibles and Minimum Fireplace Clearances sections 2 Make gas and electrical connections Refer to the Gas Connection section Test the pilot Must be as per diagram in the Valve Description section 3 Install Flue Connector Refer to the Flue Connector Installation section 4 Install vent...

Страница 10: ...aa aaaaa The minimum clearance from the side of the appliance to a combustible side wall is 9 inches 229mm The minimum clearance from the top of the louver to a combustible mantel is 14 inches 356mm The minimum height from the top of the louver to the ceiling is 36 inches 914mm Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non...

Страница 11: ...t with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approvedfittings Alwaysprovideaunionsothat gas lines can be easily disconnected for burner or fan servicing Flare nuts for copper lines and flex connectors are usually considered to meet thi...

Страница 12: ...rom sharp edges When connected with 120 volts the appliance must be electrically grounded in accordance with local codes or in the absence of local codes the current CSA C22 1 in Canada or with the National Electrical Code ANSI NFPA 70 1987 in USA NOTE This unit is equipped with a heat sensor thermodisc which will prevent the blower from operating until the unit reaches the correct temperature Gre...

Страница 13: ... flue liner inside the fireplace to the flue collar with three sheet metal screws 3 Place the appliance on the hearth Push the appliance into the fireplace and at the same time slide the plate back onto the ap pliance 4 Replace the screw holding the plate just before completely pushing the appliance into the fireplace For PROPANE Units and Units Equipped with DC Spark Boxes For installation of the...

Страница 14: ... A3 diametertypeB Ventorapprovedaluminium flex liner may also be used with a 4 to 3 reduc ing adapter Consult venting charts and local code requirements The Regency Insert incorporates its own internal draft hood so no additional external draft hood is required Check periodically that the vent is unrestricted and an adequate draft is present when the unit is in operation Beforeinstallingtheventsys...

Страница 15: ...cy Installer at the time of installation or service a scrap piece of sheet metal or other noncombustiblematerial intheupperlouver thiswillpreventthenaturalconvectionofthe unit from interfering with the test Note The smoke should be drawn into the louver If the smoke is still not drawn in turn the unit off and check for the causeofthelackofdraft Ifnecessary seek expert advice OPTIONAL BRICK PANEL 1...

Страница 16: ...29 27 30 27 23 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Spread vermiculite around the firebox base Then take some embers and spread them over the vermiculite as shown 3 Fit log 27 23 into the pins on the back log tray 4 Fit log 27 24 into the pins on the middle right hand side of the burner 27 23 27 24 27 24 Read th...

Страница 17: ...f the burner 5 Rest the top of log 27 25 in the notch in log 27 24 and rest the bottom end of log 27 25 on the firebox base 7 Fit the top end of log 27 27 into the pin in log 27 23 and rest the bottom end of log 27 27 against the 2nd grate post 2nd Grate Post 27 24 27 25 27 25 27 26 27 26 27 27 27 23 27 27 ...

Страница 18: ...the pin on the front left side of the burner in front of the 1st grate post and rest the right end of log 27 29 onto the notch on log 27 27 1st Grate Post 10 Fit the top of log 27 30 into the pin on the right side of log 27 23 and rest the bottom of the log on the notches in logs 27 26 and 27 24 27 28 27 29 27 27 27 29 27 23 27 30 27 26 27 24 Notch ...

Страница 19: ...f the burner as shown Ensure not to cover any burner ports 27 25 27 28 27 24 27 26 27 29 27 27 27 30 12 Place rock wool along side the embers on the front of the burner as shown Ensure not to cover any burner ports 13 Separate platinum embers and place on the burner just in front of the logs Avoid stacking platinum embers ...

Страница 20: ... holes in it with the holes in the side panels Using the screws provided attach from the top of the panel the holes in the top panel are slightly larger than the holes in the side panel to facilitate easier installation See diagram 1 Hint Don t tighten the trim to the bottom of the faceplate side panels with the screws provided See diagram 1 Diagram 1 Diagram 2 4 Place the trim on the assembled fa...

Страница 21: ...ure WARNING The use of substitute glass will void all product warranties Do not operate the appliance if the glass panel s are removed cracked or broken Replacement of the glass panel s should be done by a qualified service person FLUSH LOUVERS 1 The Top Louver is held in place by Spring Clips Push into place as shown 2 Install the Spring Hinges on the left and right side of the bottom of the Fire...

Страница 22: ...k Black 904 782 Velcro Hook Black Installation of LPG Conversion Kit 1 Turn the unit off and allow it to cool to room temperature 2 Shut off gas supply 3 Unplug or disconnect power source to stove 4 Remove glass front see Door Glass Replacement section in the manual 5 Remove logs and brick panels if installed 6 Remove the Grate by removing the 2 screws one on each side of the grate 7 Remove the Bu...

Страница 23: ...nto place Then install the ground wire onto the bottom lug and reinstall the 11 32 nut star washer to secure in place 22 Attach the label This unit has been converted to LPG near or on top of the serial decal 23 Replace the yellow NG label with red LPG label 19 Replace Burner Tray and reverse steps 6 to 1 20 Adjust the burner aeration setting from 1 8 to 3 16 as required for the best flame picture...

Страница 24: ...Sparker mounting bracket 34 Mount the heat shield to the DC Sparker Secure into place with the velcro which is provided in the kit Heat Shield 30 Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield 36 Tie up the loose wire with the wire clip 35b Location to mount the DC Sparker 35a Remove the bottom louver if in place by unscrewing the four scre...

Страница 25: ...ith the wire connectors from the fan speed control Place clips over wires and tuck into side trim 2 Lift the unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under unit Bottom Trim Bracket Push in Corners 3 Completely secure full screen door to the unit by securing 4 screws to the Left and Right Side Trim 4 Secure the Top Frame by sliding it on the screws at the t...

Страница 26: ...ch Bottom Frame Hinge Location 5 Install Spring Hinges to the Left and Right Side of the bottom of the firebox using 2 screws per hinge 7 Install the Left and Right Side Screen Doors by placing over top of the hinges on the faceplate Hold the door at a 45 degree angle to avoid scratching the faceplate Hinge Screen Door 8 Close screen doors ...

Страница 27: ...witch in the control box 6 Attach the 2 bottom louver hinges to the bottom flange on the firebox using 2 screws per hinge Diagram 6 Diagram 7 4 Tuck the wires into the clip to keep them away from the insert using the clip provided Attach the clip to the rear of the faceplate to en sure that the wires do not touch the side of the unit The power cord should be run behind the inner faceplate panel 5 ...

Страница 28: ...ach the bottom louver to the 2 hinges using 2 screws per hinge When complete flip the louver up to close 9 Take the outer faceplate line up the openings on the left and right legs and install onto the inner faceplate panel pins 8 Hook door frame on 2 pins over glass door in locations shown below in Diagram 9 Diagram 8 Final Install ...

Страница 29: ...arth trim is evenly space on either side of the backing plate 5 Reinstall backing plate 6 Reinstall outer faceplate If no holes are present on the backing plate proceed to the Step 3 2 If screw holes are present on backing plate secure the hearth trim to backing place with 2 screws on each side If no screw holes are present 3 Remove backing plate by removing 4 screws lay down flat Diagram 1 Screw ...

Страница 30: ...ction from extreme heat is very important Run wires from the fireplace to that location Use Thermostat Wire Table 2 Connect the two wires to the gas valve See diagram below CAUTION Do not wire millivolt remote control wires to 120V wire 3 Install 3AAAalkaline batteries in transmitter and 4 AA alkaline batteries in the receiver Install the receiver and its cover in the wall Switch the remote receiv...

Страница 31: ...dthrough the following check list 1 Read and understand these Instructions before operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent possible shock LIGHTING PROCEDURE NOTE For all propane units and units equipped with electric spark boxes see Copy of Lighting Plate Instruc tions section for more details IMPORTANT Gas on off knob cannot be turned from PILOT t...

Страница 32: ...s control which has been under water E This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air STOP Read the safety information above on this label LIGHTING INSTRUCTIONS 1 Push in gas control knob slightly and turn clockwise to OFF Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not for...

Страница 33: ...the Flush Front GOLD PLATED ACCESSORIES The24caratgoldplatedfinishontheaccessories requires little maintenance and need only be cleanedwithadampcloth DONOTuseabrasive materials or chemical cleaners as they may harm the finish and void the warranty Clean any fingerprints off before turning the unit on If the top louvers start to discolour check the door gasket seal and replace if necessary AUTOMATI...

Страница 34: ...nder the left side of the firebox bottom 13 Remove valve assembly from stove body by removing 3 phillips screws 14 Remove the valve from the bracket and replace Reverse steps to install valve DOOR GLASS REPLACEMENT Your Regency stove is supplied with high temperature 5mmNeoceramceramicglassthat will withstand the highest heat that your unit will produce In the event that you break your glass by im...

Страница 35: ...de Plate 12 910 343 Spill Switch 13 Spill Switch Bracket 17 532 012 Baffle 532 910 Flush Louver set Black 532 912 Flush Louver set Gold Black 532 914 Flush Louver set Steel Black 21 Top Flush Louver 23 Bottom Flush Louver 532 901 Brick Panel Set Standard Brown 532 902 Brick Panel Set Standard Red 532 903 Brick Panel Set Herringbone Brown 33 Brick Panel Rear 34 Brick Panel Left Side 35 Brick Panel ...

Страница 36: ...910 190 Piezo Ignitor Nut 56 910 076 Pilot Assembly SIT 3 flame NG 910 077 Pilot Assembly SIT 3 flame Propane 57 910 341 Thermopile 58 910 096 Pilot Hood 59 910 030 Electrode 904 162 43 Orifice NG 904 163 54 Orifice LP 61 402 526 Grate Diffuse Assembly 62 533 535 Burner Assembly NG LP 533 930 Complete Log Set 534 969 Conversion to Propane Kit Not available as a replacement part ...

Страница 37: ...t Description Flush Door 530 547 P Flush Door Assembly Complete 107 936 243 Gasket Adhesive Backed 7 8 153 Glass Side Trim 154 Flush Glass 157 Screw 10 24 x 1 2 Truss Head 158 402 033 Flush Glass Bracket Not available as a replacement part FLUSH FRONT 107 158 157 153 154 107 ...

Страница 38: ...6 Faceplate Standard Contour Trim Left 532 919 Faceplate Trim Set Oversize Contour Black 141 Faceplate Contour Oversize Side Right 142 Faceplate Contour Oversize Top 143 Faceplate Contour Oversize Side Left 144 Trim Contour Oversize Side Right 145 Trim Contour Oversize Top 146 Trim Assy Contour Oversize Side Left 402 918 Faceplate Trim Set Zero Clearance Kit Contour 532 927 Custom Faceplate 190 Sc...

Страница 39: ...ited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfectionisneither guaranteednor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general pract...

Страница 40: ...__________________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all y...

Отзывы: