background image

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

918-523b

MODELS:   P42-NG4 Natural Gas   P42-LP4 Propane

P42 Gas Fireplace

WARNING:  
If the information in these instructions are not followed exactly, 
a  fi re or explosion may result causing property damage, 
personal injury or loss of life. 

FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and 
liquids in the vicinity of this or any other appliance.

Installation and service must be performed by a qualifi ed 
installer, service agency or the gas supplier.

FOR YOUR SAFETY
What to do if you smell gas:

Do not try to light any appliance

Do not touch any electrical switch: 
do not use any phone in your 
building.

Immediately call your gas supplier 
from a neighbour's phone. Follow 
the gas supplier's instructions.

If you cannot reach your gas 
supplier, call the fi re department.

Owners & 

Installation Manual

Tested by:

Installer: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner: Please keep these instructions for future reference.

07/30/09

www.regency-fi re.com

Содержание Gas Fireplace P42-LP4

Страница 1: ...tallation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fir...

Страница 2: ...EVER WILL CAUSE BURNS GLASS UNTIL COOLED ALLOW CHILDREN TO TOUCH GLASS CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPECIALLY THE FIREPLACE GLASS AND SHOULD STAYAWAYTOAVOIDBURNSORCLOTHINGIGNITION ...

Страница 3: ...nd the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance installation must comply with the manufacturer s installation instructions and local codes if any In the absence of local codes...

Страница 4: ...4 REQUIREMENTS MA Code CO Detector 5 INSTALLATION Important Message 6 Before You Start 6 General Safety Information 6 Installation Checklist 6 Manufactured Mobile Home Additional Requirements 7 Locating Your Gas Fireplace 7 Unit Specifications 7 Heatwave Optional Duct System Kit 946 556 7 Optional Hearth 7 Clearances 8 Mantels 8 Mantel Leg Clearances 8 Framing And Finishing 9 Top Assembly Nailing ...

Страница 5: ...none follow the National Fuel Gas Code ANSI Z223 1 or Natural Gas and Propane Installation Code CSA B149 1 This appliance must be installed in accordance with the Standard CAN CSAZ240 MH Mobile Housing in Canada or with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States or when such a standard is not applicable ANSI NCSBCSA225 1 NFPA501A Manufactured...

Страница 6: ...ade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon...

Страница 7: ...LIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONALSERVICEPERSON MORE FREQUENT CLEANING MAY BEREQUIREDDUETOEXCESSIVE LINTFROMCARPETING BEDDING MATERIAL ETC IT IS IMPERATIVE THATCONTROLCOMPARTMENTS BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN GENERAL SAFETY INFORMATION 1 The appliance installation must conform with local codes or in the absence of...

Страница 8: ...4 The P42 Direct Vent Gas Fireplace can be installedinarecessedpositionorframedout into the room as in A B C D See Diagram 1 HEARTH A hearth is not mandatory but is recommended for aesthetics and for added safety 5 This appliance is Listed for bedroom installationswhenusedwithaListedMillivolt Thermostat Some areas may have further requirements check local codes before installation 6 The P42 Direct...

Страница 9: ...nt may discolour Maximum 1 1 2 projection at 2 minimum clearance CLEARANCES The clearances listed below are Minimum distances unless otherwise stated A major cause of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Clearanc...

Страница 10: ...chnology Co Axial system The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to t...

Страница 11: ...ed above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public property 84 2 1m N Clearance under veranda p...

Страница 12: ...5 includes all the parts needed to install the P42 with a maximum run of 4 feet 1 6 7 8 dia flexible liner 4 ft length 2 4 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 2 Drill Point stainless steel 4 If longer runs are needed the Regency Direct Vent system Flex 946 516 includes all the p...

Страница 13: ...ack N A N A N A 4DALB N A TC 4DLTB Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 N A Extension Pipe 16...

Страница 14: ... HC N A N A N A N A TM 4ST36 Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK N A Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigi...

Страница 15: ...asured from the back standoffs to the inside mounting surface of termination cap For siding other than vinyl furring strips may be used instead of the vinyl siding standoff to create a level surface to mount the vent terminal The Terminal must not be recessed into siding Measure the wall thickness including furring strips If a Vinyl Siding Standoff is required it must be used with vinyl siding mea...

Страница 16: ...ations section Note Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe venting systems Rigid Pipe Systems 4 100mm inner diameter 6 5 8 168mm outer diameter Regency Flex 4 100mm inner diameter 6 7 8 175mm outer diameter Rigid Pipe Systems Maintain a 1 1 4 32mm clearance to combustibles Regency Flex Maintain a 1 1 2 38mm clearance to combustibles Horizontal vent must be supporte...

Страница 17: ...2 A minimum of 6 ft 1 8m vertical from base of unit is required if two 90o elbows are used 3 Minimum distance between elbows is 2 ft 0 6m Maintain a 1 1 4 clearance to combustibles for rigid pipe systems and 1 1 2 for Regency Flex Vent Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall All Rigid Pipe Systems 4 inner diamete...

Страница 18: ...ht vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas Maximum two 45o elbows allowed Vent restrictor 6 must be used in shaded area in diagram below Vent must be supported at offsets The P42 is approved for a 37 ft 11 3m straight vertical including a 20 0 5m horizontal offset using two 90o elbow two 45o elbows equal one 90o elbow with rigid pipe ve...

Страница 19: ...d pipe vent systems for Propane and Natural Gas as per the diagram below No Vent restrictor is required Vent must be supported at offsets The P42 is approved for a 37 ft 11 3m straight vertical withrigidpipeventsystemsforPropane and Natural Gas as per the diagram below Vent restrictor 6 must be used Diagram 3 Diagram 4 Note Regency Direct Vent System Flex is only approved for horizontal terminatio...

Страница 20: ... length of the chimney See the Venting Arrangements on next page for minimum and maximum heights Masonry chimneys may take various contours which the flexible liner will accommodate However keep the flexible liner as straight as possible avoid unnecessary bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Description 946 529 Co linear DV...

Страница 21: ...nt Gas Fireplace 20 INSTALLATION VENTING ARRANGEMENTS VERTICAL TERMINATIONS with Co linear Flex System for both Residential Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations ...

Страница 22: ...on NEVER install the snorkel upside down Diagram 3 NOTE For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every in ner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional HORIZONTAL TERMINATIONS 1 Set the unit in its desired locat...

Страница 23: ... in the fully twist locked position and sealed Diagram 1 Diagram 2 Diagram 7 NOTE For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every in ner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional Diagram 6 9 Install wall thimble ...

Страница 24: ...rmination hood where excessive snow or ice buildup may occur Besuretocheckventtermination area after snow falls and clear to prevent accidental blockage of venting system When using snow blowers makesuresnowisnotdirectedtowards vent termination area Note To make the installation more aesthetically p l e a s i n g w e recommendframing out a square to mount the terminal to INSTALLATION PROCEDURES fo...

Страница 25: ...n the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 3mm wide flat screwdriver Note Output capacity The efficiency rating of the appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system Vent height may or may not change ...

Страница 26: ...s from the protectivewrapping Handlethepanelswith care as they can break easily Note The logs must not be in the unit 3 Remove the metal channel from the firebox top and use it later for installing the top brick panel refer to Diagram 1 Diagram 1 Metal Channel 4 Insert the back brick panel first by carefully slipping it between the back wall of the firebox and the rear log bracket front back 5 Ins...

Страница 27: ...llowing a Front Right Log b Front Left Log c Rear log d Embers e Rockwool f Vermiculite g Platinum Embers supplied with packaged manual 1 Remove the logs from the box and carefully unwrap them The logs are fragile handle with care Do not force into position 2 Place the rear log on the rear log support in the back of the unit with the flat side of the log facing the back of the unit Carefully push ...

Страница 28: ... the slot on the bottom door bracket Repeat for 2nd and 3rd spring See diagram 3 FLUSH LOUVERS 1 Install the top louver by sliding the two bracket clips into the brackets located underneath the top of the firebox Diagram 1 2 Attach the 2 bottom louver hinges to the bottom flange on the firebox using 2 screws per hinge Diagram 1 To remove the flush door reverse the above steps Note Top and bottom l...

Страница 29: ... bay door and secure with 1 screw on each end Note Top and bottom louvers and brackets are different OPTIONAL BAY DOOR The Bay louvers MUST be used with the Bay glass option The optional Bay door is an overlay on the flush front The standard flush door and glass must remain on the unit 1 Unhook the 2 spring loaded hooks from the bottom of the flush door 2 Hook the top of the bay door over the flus...

Страница 30: ...hilips Screws located on the inside top of the outer frame of the appliance Also remove the center screw 1 Before beginning the installation remove the Glass Door from the unit Refer to the manual for instructions Screw Screw Screw Cut Outs Bottom Flange b Slide the cut outs in the Top and Bottom Flange of the Full Screen Door Frame under the screw heads which were loosened in step 3a Once the Fra...

Страница 31: ... Screws provided 5 Place the Bottom Grill near hinge Flip the hinge over the Bottom Grill and secure with 2x 8 Self Tapping Philips Screws per side Bottom Grill Hinge Location 4 Install the Hinges to the Hinge Brackets on the left and right side of the bottom of the outer frame secure using 2x 8 Self Tapping Philips Screws per hinge Backside of Full Screen Door Frame Shown 6 Loosen the 2x 8 Self T...

Страница 32: ...s located on the inside top of the firebox Push in place Top Grill 9 Install the Left and Right Side Screen Doors in the fully open position by placing over top of the hinges on the Full Screen Door Frame NOTE Failure to install the doors in the fully open position could result in paint damage to the surface of the door Hinge Screen Door ...

Страница 33: ...re the terminal block in case the fan is installed at a later date However DO NOT leave this connection live until the fan is installed Caution Ensurethatthewiresdo not touch any hot surfaces and are away from sharp edges Thermodisc Green Green Ground White Neutral Black Live Black White White by others by others Black Black Ground for mobile home 120 VAC 60HZ by others Fan Rotary Speed Control ON...

Страница 34: ...Regency P42 4 Zero Clearance Direct Vent Gas Fireplace 33 INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes ...

Страница 35: ...re details IMPORTANT Gas on off knob cannot be turned from PILOT to OFF unless it is partially depressed OPTIONAL REMOTE CONTROL UsetheRegency RemoteControlKit approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter a receiver and a wall mounting plate 1 Choose a convenient location on the wall to install the receiver and the rec...

Страница 36: ...he floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbors phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Us try to repair it call a qualified service technician Force or attempted repair may result in ...

Страница 37: ...efects in your appliance Blower Regency gasappliancesusehightechblowers to push heated air farther into the room It is not unusual for the fan to make a whirring sound when ON This sound will increase or decrease in volume depending on the speed setting of your fan speed control Burner Tray The burner tray is positioned directly under the burner tube and logs and is made of a different gauge mater...

Страница 38: ...heat to burn someone If for any reason a log should need replacement you must use the proper replacement log The position of these logs must be as shown in the diagrams under Log Installation Note Improper positioning of logs may create carbon build up and will severely alter the unit s performance which is not covered under warranty THERMOPILE THERMOCOUPLE 1 Remove the top louver and open the bot...

Страница 39: ...ve valve Hint If you are using black pipe ensure that there is a union by the valve otherwise removal will be almost impossible Grounding lug detail REMOVING THE FAN 1 Shut the power off 2 Remove the bottom louver 3 Removeterminalblockcoveranddisconnect the fan wires 4 Disconnect white fan wire from the terminal block 5 Disconnect black fan wire from the thermodisc 6 Disconnect fan ground wire 7 L...

Страница 40: ...heck the manifold pressure 15 Reinstall the vermiculite embers rockwool and logs as needed 16 Install and close the door and replace the louvers MAINTENANCE 1 Attach the valve bracket to the valve with the 4 m5x8 metric screws provided 2 Reconnect the gas out 90o elbow flare fitting with an 11 16 wrench 3 Reconnect the gas out flare nut with a 13 16 wrench 4 Reconnect the quick drop out thermocoup...

Страница 41: ...Red Set 33 Brick Panel Back 34 Brick Panel Left Side 35 Brick Panel Right Side 36 Brick Panel Top 601 170 Top Front Brick Trim 38 601 092 Baffle 39 601 171 Restrictor 40 510 994 Rigid Pipe Adapter 58 910 413 2 switch cover plate 59 910 420 Double gang box 60 910 363 Wall Switch White 61 904 687 3 8 Clamp Connector 97 910 417 White Knob 99 910 412 Fan Speed Control wall mounted 946 556 Heat Wave Du...

Страница 42: ...lot Assy S I T 3 Flame LP 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 69 904 689 33 Orifice N G 904 641 50 Orifice Propane 936 170 Orifice Gasket 70 601 133 Pilot Flame Bracket 75 Valve Access Plate 79 601 535 Burner Assy 82 600 555 Burner Grate Assy 84 Air Shutter Gear Assembly Male 88 260 565 Air Shutter Gear Assembly Female 904 565 Hex key 3 16 AF 89 600 964 P42 Log Set 90 910 421 Pilot ON...

Страница 43: ...asket Tadpole 140 948 042 Spring Hinge 600 965 Finishing Trim Black 141 Trim Side Left Black 142 Trim Side Right Black 143 Trim Top Black 600 943 Double Screen Door Complete Optional 171 Door Frame Assembly Left 172 Door Frame Assembly Right 174 511 085 Handle 175 602 540 Door Support Frame Assembly 178 948 257 Lift Hinge on Door 179 948 258 Lift Hinge on Frame 180 512 546 Door Latch Assembly Push...

Страница 44: ...6 Brick Panel Bay Std Red 113 Bay Door Trim Each Black 602 932 Bay Door Trim Set Gold 600 954 Bay Louvers Set Black 600 956 Bay Louvers Set Gold Black 600 957 Bay Louvers Set Steel Black 115 Bay Louver Assy Top 116 Bay Louver Assy Bottom 117 904 196 Magnet 1 round 120 400 189 Flush Glass Retainer Bracket 122 948 216 Regency Logo Plate Not available as a replacement part Part Description Part Descr...

Страница 45: ...____________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _______...

Страница 46: ...____________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _______...

Страница 47: ...____________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _______...

Страница 48: ...r agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the...

Страница 49: ...__________________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door Fireplace Products International Ltd ispleasedtoextendthisLimited Lifetime Warranty to the original purchaser of a Regency Product See the inside back co...

Отзывы: