18
FG39-2 Freestanding Gas Stove
installation
Pipe Length
Round Support
Box/Wall Thimble
Round
Support Box/
Wall Thimble
Vertical
Terminal
Storm Collar
Flashing
Ceiling Firestop
1.2m
Pipe Length
Adj.Pipe Length
360mm - 610mm
o
90 Elbow
Wall Thimble
AstroCap
Termination Cap
DURA-FLUE
TERMINATION
Planning Your Dura-Flue
Installation
There are two basic types of Dura-Flue Room
Sealed System installations: horizontal termi-
nation and vertical termination. Confirm the
maximum horizontal run and maximum vertical
rise from the diagrams on page 10.
When planning your installation, it will be nec-
essary to select the proper length of flue pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
important to note the wall thickness. (The wall
thimble is suitable for .6m x 1m or .6m x 2m
wall construction.) Select the amount of verti-
cal rise desired for "vertical-to-horizontal" type
installations.
Warning: Always maintain required clear-
ances (air spaces) to nearby combustibles
to prevent a fire hazard. Do not fill air spaces
with insulation.
The minimum clearance requirements between
the outer wall of the flue pipe and nearby com-
bustible surfaces is 32mm. Be sure to check the
flue termination clearance requirements from
decks, windows, soffits, gas regulators, air supply
inlets and public walkways as specified in the
Exterior Flue Termination Locations on page 9
and in your local building codes.
To determine the length of flue pipe required
for vertical installations, measure the distance
from the unit flue outlet to the ceiling, the ceiling
thickness, the vertical rise in an attic or second
storey, and allow for sufficient vertical height
above the roof line.
For multi-storey applications, fire stops are
required at each floor level. If an offset is
needed, additional pipe, elbows and supports
will be required.
Do not exceed the maximum number of elbows.
One 90
o
for horizontal terminations and two 45
o
for vertical termination.
DURA-FLUE
COMPONENTS
You will require the following components with
your new Regency Room Sealed Freestand-
ing Gas Stove. Please review your product to
make sure you have everything you need. In
the flue that you are missing any part, contact
your dealer.
Note: These are the minimum pieces re-
quired. Other parts may be required
for your particular installation. See
below for a list of flue parts.
If installing termination on a siding covered wall,
a vinyl siding standoff or furring strips can be
used in order to ensure that the termination is
not recessed into siding.
The vinyl siding standoff is required for walls
with vinyl siding.
Minimum components for a Dura-Flue
Horizontal Installation:
A) Dura-Flue Horizontal Termination Kit
B) Wall Thimble (required for combus-
tible walls)
Minimum components for a Dura-Flue
Vertical Termination:
C) Dura-Flue Vertical Termination Kit
The Simpson Dura-Flue Room Sealed System
offers a complete line of component parts for
installation of both horizontal and vertical installa-
tion. Many items are offered in decorative black,
as well as galvanized finish. The galvanized pipe
and fittings are used for concealed locations such
as attics or where corrosion is a factor, such as
above the roof line. Decorative brass trim kits
are available for both wall thimbles and ceiling
support boxes.
Description
Horiz. Termination components:
90
o
black elbow, wall thimble
cover,
horiz. square termination cap,
1.2m
black pipe, 360mm-610mm
adjustable black pipe
Basic Horiz. Termination Kit
includes: 90
o
black elbow, wall
thimble cover, horiz. square
termination cap
Vert. Termination Kit includes
0/12 - 6/12 pitch adjustable
flashing, storm collar, low profile
term. cap
152mm Pipe Length-Black
229mm Pipe Length-Black
304mm Pipe Length Galv.
304mm Pipe Length-Black
610mm Pipe Length Galv.
610mm Pipe Length-Black
914mm Pipe Length Galv.
914mm Pipe Length-Black
1219mm Pipe Length Galv.
1219mm Pipe Length-Black
219mm - 372mm
Adj. Pipe Length-Black
432mm - 610mm
Adj. Pipe Length Black
45
O
Elbow Galv.
45
O
Elbow-Black
45
O
Elbow-Swivel Galv.
90
O
Elbow-Swivel Galv.
Dura-Flue Basic
Horizontal Kit
1 90
o
Elbow
1 Wall Thimble Cover
1 Astro Cap
Содержание FG39-LPG2
Страница 15: ...FG39 2 Freestanding Gas Stove 15 installation 1 2m 13mm 13mm 102mm 04 19 18 a ...
Страница 46: ...46 FG39 2 Freestanding Gas Stove ...
Страница 47: ...FG39 2 Freestanding Gas Stove 47 ...