Regency F1104S Скачать руководство пользователя страница 2

2    | 

F1104S / F3104L Freestanding Woodstove

2    |

Thank-you for purchasing a 

REGENCY FIREPLACE PRODUCT.

The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product 

that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning.

“This wood heater has a manufacturer set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise 

operate this wood heater in a manner inconsistent with operating instructions in this manual." Failure to follow the manual details can lead to smoke and CO 

emissions spilling into the home. It is recommended to have monitors in areas that are expected to generate CO such as heater fuelling areas.

“U.S. ENVIRONMENTAL PROTECTION AGENCY

 Certified to comply with 2015 particulate emission standards using crib wood". Not approved for sale 

after May 15, 2020.”

Model Regency F1104 – 3.0 g /hr.

Model Regency F3104 - 4.2 g/ hr.

SAFETY NOTE

: If this woodstove is not properly installed, a house fire may result. For your safety, follow the installation instructions, contact local building, 

fire officials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.

The following statements are required by the Environmental Protection Agency:

“This manual describes the installation and operation of the Regency F1104 wood heater. This heater meets the 2015 U.S. Environmental Protection Agency’s 

crib wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 10,600 BTU/hr. to 

34,700 BTU/hr.” This unit has been tested using 5G series and generates the best efficiency when operated using well-seasoned wood and installed in the 

main living areas where the majority of the chimney is within the building envelope and fully lined.”

“This manual describes the installation and operation of the Regency F3104 wood heater. This heater meets the 2015 U.S. Environmental Protection Agency’s 

crib wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 11,900 BTU/hr. to 

42,900 BTU/hr.” This unit has been tested using 5G series and generates the best efficiency when operated using well-seasoned wood and installed in the 

main living areas where the majority of the chimney is within the building envelope and fully lined.”

"It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual, or if any parts are removed. “

It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual.

CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS, COAL,

PLASTIC, GARBAGE, SULPHUR OR OIL MAY DAMAGE THE HEATER

"This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as 

compared to softwoods or to green or freshly cut hardwoods."

DO NOT BURN: 

 

•  Treated wood

•  Lawn clippings or yard waste

•  Manure or animal remains

•  Coal

•  Materials containing rubber including tires

•  Saltwater driftwood or other previously salt water 

saturated materials

•  Garbage

•  Materials containing plastic

•  Unseasoned wood

•  Cardboard

•  Waste petroleum products , paints or paint thinners or asphalt products

•  Paper products, cardboard, plywood or particle 

board. The prohibition against burning these 
materials does not prohibit the use of fire starters 
made from paper, cardboard, saw dust, wax and 
similar substances for the purpose of starting a 
fire in a wood heater

•  Solvents

•  Materials containing asbestos

•  Colored Paper

•  Construction or demolition debris

•  Trash

•  Railroad ties

Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke. 

The authority having jurisdiction (such as Municipal Building Department, Fire Department, Fire Prevention Bureau, etc.) should be consulted before instal

-

lation to determine the need to obtain a permit.

This unit must be connected to either a listed factory built chimney suitable for use with solid fuels and conforming to ULC629 in Canada or UL-103HT in the 

United States of America or code approved masonry chimney with flue liner.

F1104 is tested and certified to ULC-S627 and UL1482.

F3104 is tested and certified to ULC-S627 and UL1482.

SAVE THESE INSTRUCTIONS

Содержание F1104S

Страница 1: ...4 919 034e MODELS F1104S F3104L Freestanding Woodstoves 05 18 17 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ...st conditions this heater has been shown to deliver heat at rates ranging from 11 900 BTU hr to 42 900 BTU hr This unit has been tested using 5G series and generates the best efficiency when operated using well seasoned wood and installed in the main living areas where the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood ...

Страница 3: ...F1104S F3104L Freestanding Woodstove 3 3 ...

Страница 4: ...ghs 13 Recommended Heights For Woodstove Flue 14 Mobile Home Installation 14 Listed Components For Mobile Home Installation 15 Stainless smoke deflector installation 16 Brick Flue Baffle Secondary Air Tube Installation 17 Brick Installation 18 Door Handle 18 Glass Installation 18 Optional Accessories 18 Screen Door 18 OPERATING INSTRUCTIONS Operating Instructions 20 First Fire 20 Draft Control 20 ...

Страница 5: ...ITY MODÈLE S2100 ICC EXCEL 2100 SUPER VENT 2100 AUX ÉTATS UNIS CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITY MODÈLE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MODÈLE DVL GSW SUPER PIPE 6 METAL FAB À DOUBLE PAROI CONNECTÉ À L UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS SECURITY MODÈLE S2100 OU MODÈLE ASHT SELKIRK MODÈLE SSII OLIVER MACLEOD PRO JET 3103 SIMPSO...

Страница 6: ...TEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITYMODÈLE DP OU OLIVER MACLEOD PRO VENT PV AVEC SYSTÈME DE CHEMINÉE HOMOLOGUÉ SECURITY MODÈLE S2100 ICC EXCEL 2100 SUPER VENT 2100 AUX ÉTATS UNIS CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITY MODÈLE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MODÈLE DVL GSW SUPER PIPE 6 METAL FAB À DOUBLE PAROI CONNECTÉ À L UN DES S...

Страница 7: ...nding Woodstove 7 7 dimensions F1100S UNIT DIMENSIONS Contemporary Door Classic Door ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Страница 8: ...8 F1104S F3104L Freestanding Woodstove 8 dimensions F3100L UNIT DIMENSIONS Contemporary Door Classic Door ...

Страница 9: ...ction 11 Do not connect this unit to a chimney serving another appliance unless approved by your local building authority 12 A chimney connector cannot pass through an attic or roof space closet or similar concealed space or a floor ceiling wall or partition of combustible construction In Canada if pas sage through a wall or partition of combustible construction is desired the installation shall c...

Страница 10: ... 10 32 16 23 5 with Rear Deflector 20 12 10 34 18 5 23 5 NOTE Be aware that local Codes and Regulations may override some clearances listed in this manual Check with your local inspector Residential Installation C Vent Single Wall Unit From Unit From Corner From Flue Center line A B C D E F Small F1104S with Airmate 13 11 8 25 17 5 20 with Rear Deflector 15 10 5 11 27 17 23 Large F3104L with Airma...

Страница 11: ... as defined by local codes extend ing beneath the heater and a minimum of 6 from each side and minimum 16 from the front face of the stove and minimum 6 or the rear clearance to combustibles whichever is smaller from the rear of the stove NOTE In Canada floor protection must extend 18 to the front and 8 to each side of the stove From From Flue Min Min Hearth Unit Unit Center line Width to Rear Wal...

Страница 12: ...heatdeflectorissuppliedwiththestove andmustbeinstalledunlesstheoptionalairmate has been selected It stops the heat radiated from the flue collar from overheating the rear wall The rear heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Shown with contemporary door Pedestal Assembly Small 073 925 Large 063 925 1 Foreasierassembly tipthestoveonitsback onto a soft surfac...

Страница 13: ... ups back smokingwhendoorisopen and dirty glass It might be sufficient to initiallytrywiththeminimumrequired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof with roofing compound Secure the flashing to your roof with nails or screws 5 Place the storm collar over the flashing sealing the joints ...

Страница 14: ...Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chimney special methods are needed Ensure that an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure MASONR...

Страница 15: ...ney clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through Thereshallbeaminim...

Страница 16: ...at sea level 6 ft Example b One 90 deg elbow 2 ft 2 ft of horizontal run 4 ft one T 3 ft Total Addition at sea level 9 ft Recommended Flue Height Elevation Example a Example b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 Once you have properly marked the position of your unit and the floor protection as outlined in the Residential Installation items 1 through 8 a sup...

Страница 17: ...ON The Regency Small and Large Freestanding pedestal units are approved for installation in a Mobile Home if one of the following pipe systems is used U S Installation METALBESTOS SSII Qty Part Description 1 6DS VK Connector Kit 1 6TMH Shield Support 1 6TAF 6 Flashing 1 6T 36 Chimney Length 1 6T 18 Chimney Length 1 6T CT Rain Cap PRO JET 3103 Qty Part Description 1 PV06 TK Connector 1 CSB Shield S...

Страница 18: ... with 2 hand tightened bolts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram ...

Страница 19: ...raft problems may occur if the bafflesare improperly positioned Checkthe position of the brick baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox The Large Stoves F3104L and S3100L are shipped with one of the secondary air tubes loose inside the firebox It needs to be installed after the brick baffle are installed Follow the directions below Small Stove...

Страница 20: ...nto the hole inside the firebox and replace all the bricks except for the brick over the ash plug See brick diagrams 5 Place the ash plug tool beside the lid then slide the ash drawer inside Refer to the Ash Drawer Operating section Freestanding Small F1104 Pedestal Ash Drawer Kit 850 100 1 Remove the bricks from the floor of the firebox 2 If using ashdrawer discard cover plate 3 Remove the ash du...

Страница 21: ...pdated Jan 27 00 updated Aug 09 05 capitalized the word Nut Lockwasher Ground wire from power cord Ground wire from fan 8 Groun Lug d Star washer Nut Nut Star washer Grounding Lug Detail CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged groun...

Страница 22: ...n can cause serious permanent damage to the unit and void your warranty FIRST FIRE When your installation is completed and in spected you are ready for your first fire 1 Open control fully 2 Open firebox door and build a small fire using paper and dry kindling Secure door on the firebox and wait a few minutes for a 13 Allfuelburningappliancesconsumeoxygen during operation It is important that you ...

Страница 23: ... in use 2 Keep the door closed during operation and maintain all seals in good condition 3 Donotburnanyquantitiesofpaper garbage and never burn flammable fluids such as gasoline naptha or engine oil in your stove 4 Ifyouhavesmokedetectors preventsmoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverf...

Страница 24: ...terial compresses after a few fires Removal of the spacer washer shown in the diagram below will allow the latch to be movedclosertothedoorframe causingatighter seal Removeandreplacethenuts washerand spacer as shown GLASS MAINTENANCE Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glas...

Страница 25: ...Hole Cover Plate 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel F1104 F3104 STOVE MAIN ASSEMBLY Part Description Part Description 20 948 102 Spring Handle Small Gold 948 136 Spring Handle S...

Страница 26: ...y 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 56 850 121 Bottom Shield Small 850 321 Bottom Shield Large 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 140 850 126 Legs Cast Black 850 128 Legs Cast Brush Nickel 948 223 Regency Logo Nickel Not available as a replacement part PEDESTAL BOTTOM SHIELD ...

Страница 27: ...4 x 9 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 76 Brick Partial 1 1 4 x 2 x 9 77 Brick Partial 1 1 4 x 3 1 4 x 9 78 Brick Partial 1 1 4 x 4 1 2 x 3 1 4 79 Brick Partial 1 1 4 x 4 1 2 x 2 1 4 80 Brick Partial 1 1 4 x 6 1 2 x 2 1 4 81 Brick Partial 1 1 4 x 1 1 4 x 9 82 Brick Partial 1 1 4 x 3 1 8 x 4 1 2 83 Brick Partial 1 1 4 x 3 3 8 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1...

Страница 28: ...ly 6 Years Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre approved and assigned agent provided that the...

Страница 29: ...cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes ...

Страница 30: ...gal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email and te...

Страница 31: ... in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases m...

Страница 32: ......

Страница 33: ...F1104S F3104L Freestanding Woodstove 33 33 notes ...

Страница 34: ...34 F1104S F3104L Freestanding Woodstove 34 notes ...

Страница 35: ...F1104S F3104L Freestanding Woodstove 35 35 notes ...

Страница 36: ..._______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency and Classic are trademarks of FPI Fireplace Products International Ltd Copyright 2017 FPI Fireplace Products International Ltd...

Отзывы: