background image

26

     | 

F1103S  / F3103L

parts list

19

5

3

4

7

6

16

17

1

25

OR "REAR AIR DEFLECTOR"

27

29

28

37

36

35

20

BLOWER/FAN (OPTION)

40

9

30

MAIN ASSEMBLY

41

INSTALL EITHER "AIR MATE"

12

13

14

15

SCREEN DOOR (OPTION)

42

43

1)  850-142 

Door Assy - Gold F1103

 

850-141 

Door Assy - Black F1103 

 

850-143 

Door Assy - Nickel Accent F1103

 

850-144 

Door Assy - Gold Accent F1103

 

850-152 

Door Assy - Gold F3103

 

850-151 

Door Assy - Black F3103

 

850-153 

Door Assy - Nickel Accent F3103

 

850-154 

Door Assy - Gold Accent F3103

3)  846-302 

Glass - Replacement - Small/Medium F1103 

 

846-304 

Glass - Replacement - Large F3103

4)  936-243 

7/8" Adhesive Tape Gasket

5)  846-920 

Glass Retainer Clips (8/set)

6)  * 

Screw - 1/4 - 20 x 3/8"

7)  948-170/P 

Small Glass Retainer F1103 

 

948-172/P 

Large Glass Retainer F3103

8)  073-363 

Left Side Heat Shield F1103

 

073-364 

Right Side Heat Shield F1103

 

036-363 

Left Side Heat Shield F3103

 

036-364 

Right Side Heat Shield F3103

9)  846-973 

Door Handle Assembly

12)  820-375 

Ash Hole Cover Plate

13)  * 

Bolt 1/4 - 20 x 1/2 Hex Head

14)  820-376 

Retainer Plate - Ash Dump - Top

15)  * 

Nut - 1/4 - 20 Hex

16)  846-570 

7/8" Door Gasket Repair Kit

17)  846-918 

Hinge Cap - Gold (2/set)

 

948-079 

Hinge Cap Nickel (each) 

19)  948-101 

Spring Handle - Large Gold

 

948-135 

Spring Handle  - Large Nickel

F1103 & F3103 STOVE MAIN ASSEMBLY

         Part # 

Description 

 

 

                

 

Part # 

 Description 

  

20)  948-102 

Spring Handle - Small Gold

 

948-136 

Spring Handle - Small Nickel

 

846-515 

Complete Fan/Blower Assy (120 V)

25)  910-684 

Power Cord (120 V)

27)  910-142 

Thermodisc Fan AutoON/OFF

28)  910-138 

Manual/Auto Switch (2-way) 

29)  910-140 

Fan Speed Switch HI/OFF/LOW (3-way) 

30)  910-157/P 

Fan/Blower Motor (120 V)

35)  063-954 

Air Tube - 1" F3103 (Qty:1)

 

074-954 

Air Tube - 1" F1103 (Qty: 1)

36)   033-953 

Air Tube - 3/4" F1103 (Qty: 1)

 

063-953 

Air Tube - 3/4" F3103 (Qty: 3) (each)

37)  073-955 

Baffle (set) F1103

 

063-955 

Baffle (set) F3103

40)  815-557 

Rear Air Deflector- F1103

 

815-558 

Rear Air Deflector - F3103

41)  850-105 

Airmate - Sm/Med. F1103

 

850-305 

Airmate - Large F3103

42)  846-101 

F1103 Door Screen

 

846-103 

F3103 Door Screen

43)  820-483 

Stainless smoke deflector (F1103)

 

820-484 

Stainless smoke deflector (F3103)

 919-045  Manual

*Not available as a replacement part.

Содержание F1103S

Страница 1: ...4 919 045d MODELS F1103S F3103L Freestanding Woodstoves 11 08 18 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ... this heater has been shown to deliver heat at rates ranging from 11 900 BTU hr to 42 900 BTU hr This unit has been tested using 5G series and generates the best efficiency when operated using well seasoned wood and installed in the main living areas where the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a m...

Страница 3: ...F1103S F3103L 3 ...

Страница 4: ...6 Mobile Home Installation 16 Listed Components For Mobile Home Installation 17 Stainless steel smoke deflector adjustment replacement 18 Brick Flue Baffle Secondary Air Tube Installation 19 Brick Installation 20 Door Handle 20 Glass Installation 20 Optional Accessories 20 Screen Door 20 Operating Instructions 22 First Fire 22 Draft Control 22 Ash Disposal 23 Safety Guidelines And Warnings 23 Fan ...

Страница 5: ...ENT 2100 AUX ÉTATS UNIS CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITY MODÈLE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MODÈLE DVL GSW SUPER PIPE 6 METAL FAB À DOUBLE PAROI CONNECTÉ À L UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS SECURITY MODÈLE S2100 OU MODÈLE ASHT SELKIRK MODÈLE SSII OLIVER MACLEOD PRO JET 3103 SIMPSON DURA PLUS GSW MODÈLE SC OU METAL FAB ...

Страница 6: ...PAROI SECURITYMODÈLEDP OUOLIVERMACLEODPRO VENTPV AVECSYSTÈMEDECHEMINÉE HOMOLOGUÉ SECURITY MODÈLE S2100 ICC EXCEL 2100 SUPER VENT 2100 AUX ÉTATS UNIS CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI SECURITY MODÈLE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MODÈLE DVL GSW SUPER PIPE 6 METAL FAB À DOUBLE PAROI CONNECTÉ À L UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS SECUR...

Страница 7: ...F1103S F3103L 7 dimensions UNIT DIMENSIONS F1103S Dimensions F3103L Dimensions 20 508mm 20 508mm 25 1 4 641mm 25 1 4 641mm 25 1 4 641mm ...

Страница 8: ...3L dimensions WOOD STOVE OUTSIDE AIR DIMENSIONS With pedestal from base of unit to centerline 4 1 2 114mm With bottom heat shield from rear heat shield to centerline F1103S 5 127mm F3103L 7 7 8 198mm Rear Front Rear ...

Страница 9: ...ct this unit to a chimney serving another appliance unless approved by your local building authority 12 A chimney connector cannot pass through an attic or roof space closet or similar concealed space or a floor ceiling wall or partition of combustible construction In Canada if pas sage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B36...

Страница 10: ...5 with Rear Deflector 20 12 10 34 18 5 23 5 NOTE Be aware that local Codes and Regulations may override some clearances listed in this manual Check with your local inspector Residential Installation C Vent Single Wall Unit From Unit From Corner From Flue Center line A B C D E F Small F1103S with Airmate 13 11 8 25 17 5 20 with Rear Deflector 15 10 5 11 27 17 23 Large F3103L with Airmate 18 12 8 5 ...

Страница 11: ...y local codes extend ing beneath the heater and a minimum of 6 from each side and minimum 16 from the front face of the stove and minimum 6 or the rear clearance to combustibles whichever is smaller from the rear of the stove NOTE In Canada floor protection must extend 18 to the front and 8 to each side of the stove From From Flue Min Min Hearth Unit Unit Center line Width to Rear Wall G H I J K L...

Страница 12: ...15 556 Therearheatdeflectorissuppliedwiththestove andmustbeinstalledunlesstheoptionalairmate hasbeenselected Itstopstheheatradiatedfrom thefluecollarfromoverheatingtherearwall The rear heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Pedestal Assembly Small 850 115 Large 850 315 1 For easier assembly tip the stove on its back onto a soft surface to prevent scratch i...

Страница 13: ...can decrease problems such as difficult start ups back smokingwhendoorisopen and dirty glass It might be sufficient to initiallytrywiththeminimumrequired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof with roofing compound Secure the flashing to your roof with nails or screws 5 Place the storm...

Страница 14: ...re are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chimney special methods are needed Ensure that an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure MASONRY FIREPLACE T...

Страница 15: ... to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through Thereshallbeaminimum6 152 4 mms...

Страница 16: ...6 ft Example b One 90 deg elbow 2 ft 2 ft of horizontal run 4 ft one T 3 ft Total Addition at sea level 9 ft Recommended Flue Height Elevation Example a Example b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 Once you have properly marked the position of your unit and the floor protection as outlined in the Residential Installation items 1 through 8 a supply of fresh ...

Страница 17: ...y Small and Large Freestanding pedestal units are approved for installation in a Mobile Home if one of the following pipe systems is used U S Installation METALBESTOS SSII Qty Part Description 1 6DS VK Connector Kit 1 6TMH Shield Support 1 6TAF 6 Flashing 1 6T 36 Chimney Length 1 6T 18 Chimney Length 1 6T CT Rain Cap PRO JET 3103 Qty Part Description 1 PV06 TK Connector 1 CSB Shield Support 1 RRS ...

Страница 18: ...tightened bolts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smoke deflect...

Страница 19: ... may occur if the bafflesare improperly positioned Checkthe position of the brick baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox The Large Stoves F3103L and S3100L are shipped with one of the secondary air tubes loose inside the firebox It needs to be installed after the brick baffle are installed Follow the directions below Small Stove F1103S 1 If ...

Страница 20: ...he firebox and replace all the bricks except for the brick over the ash plug See brick diagrams 5 Place the ash plug tool beside the lid then slide the ash drawer inside Refer to the Ash Drawer Operating section Freestanding Small F1103 Pedestal Ash Drawer Kit 850 100 1 Remove the bricks from the floor of the firebox 2 If using ashdrawer discard cover plate 3 Remove the ash dump cover plates one i...

Страница 21: ... 00 updated Aug 09 05 capitalized the word Nut Lockwasher Ground wire from power cord Ground wire from fan 8 Groun Lug d Star washer Nut Nut Star washer Grounding Lug Detail CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for...

Страница 22: ...age to the unit and void your warranty FIRST FIRE When your installation is completed and in spected you are ready for your first fire 1 Open control fully 2 Open firebox door and build a small fire using paper and dry kindling Secure door on the firebox and wait a few minutes for a 13 Allfuelburningappliancesconsumeoxygen during operation It is important that you supply a source of fresh air to y...

Страница 23: ...door closed during operation and maintain all seals in good condition 3 Do not burn any quantities of paper gar bage and never burn flammable fluids such as gasoline naptha or engine oil in your stove 4 Ifyouhavesmokedetectors preventsmoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverfiring Stopad...

Страница 24: ...edoorframe causingatighter seal Removeandreplacethenuts washerand spacer as shown GLASS MAINTENANCE Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regencydealeronly andfollowourstep by step instructions for replacement Allow...

Страница 25: ... Test the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door of a cold stove Close the door Try to remove the paper by pulling The paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti seize lube ie never seize ...

Страница 26: ...ate 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel F1103 F3103 STOVE MAIN ASSEMBLY Part Description Part Description 20 948 102 Spring Handle Small Gold 948 136 Spring Handle Small Nickel 8...

Страница 27: ...sh Plug Tool Handle 56 850 121 Bottom Shield Small 850 321 Bottom Shield Large 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 140 850 126 Legs Cast Black 850 127 Legs Cast Gold 850 128 Legs Cast Brush Nickel 948 216 Regency Logo Gold 948 223 Regency Logo Nickel Not available as a replacement part PEDESTAL...

Страница 28: ...k Partial 1 1 4 x 4 1 2 x 3 1 2 76 Brick Partial 1 1 4 x 2 x 9 77 Brick Partial 1 1 4 x 3 1 4 x 9 78 Brick Partial 1 1 4 x 4 1 2 x 3 1 4 79 Brick Partial 1 1 4 x 4 1 2 x 2 1 4 80 Brick Partial 1 1 4 x 6 1 2 x 2 1 4 81 Brick Partial 1 1 4 x 1 1 4 x 9 82 Brick Partial 1 1 4 x 3 1 8 x 4 1 2 83 Brick Partial 1 1 4 x 3 3 8 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not av...

Страница 29: ...F1103S F3103L 29 notes ...

Страница 30: ...g switches etc 2 Glass Crazing 1 Catalyst Assembly 6 Years Prorated Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre...

Страница 31: ...ype operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados eart...

Страница 32: ... additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email and telephone conta...

Страница 33: ... us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANADA...

Страница 34: ......

Страница 35: ......

Страница 36: ..._______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency and Classic are trademarks of FPI Fireplace Products International Ltd Copyright 2018 FPI Fireplace Products International Ltd...

Отзывы: