background image

Clearances

Unless otherwise stated the clearances listed below are Minimum 
distances to combustible materials.  

Please Note: A major cause 

of chimney related 

fi

 res is due to a failure to maintain required 

clearances (air space) to combustible materials. It is of the greatest 
importance that this 

fi

 replace and vent system be installed only in 

accordance with these instructions.

Combustible Mantels

Because of the extreme heat this 

fi

 replace emits, the mantel 

clearances are critical.

 Combustible mantel clearances from top of 

the louvers are shown in the diagram below. Mantel may be installed 
anywhere in the shaded area or higher.

Note:  A non-combustible mantel may be installed at a lower 

height.

Note:  Ensure the paint that is used on the mantel and the facing 

is “heat resistant” or the paint may discolour.

G

H

I

A

D

B

E

F

C

Clearances to Combustibles

Dimension

Description

U31

A

From Unit to Sides

10” (254mm)

B

From Unit to Ceiling

47-1/2” (1207mm)

C

From Unit to Mantel

see mantel clearances

D

From Standard Surround to Sides

4” (102mm)

E

From Standard Surround to Ceiling

41-1/2” (1054mm)

F

Minimum Mantel Height

13” (330mm)

G

Maximum Mantel Depth

12” (305mm)

H

Minimum Alcove Width

48” (1219mm)

I

Maximum Alcove Depth

36” (914mm)

*No Hearth Required

Clearances when installed with a Zero Clearance Kit

Dimension

Description

U31

F

Minimum Mantel Height

20” (508mm)

G

Maximum Mantel Depth

11-1/2” (292mm)

NOTE: 

Mantel clearances for Installation into a Zero Clearance Kit 

are different. Please refer to the Zero Clearance Kit Manual 
for details.

U31 Regency Gas Insert

120

August 2008 Product Speci

fi

 cations Book

Gas Inser

ts

Gas Inserts

Отзывы: