19
Regency
®
E21-2 Gas Fireplace Insert
Installer Notice:
These instructions must
be left with the appliance.
39)
Check for gas leaks.
40)
Check inlet and outlet pressures.
41)
Check operation of fl ame control.
42)
Check for proper fl ame appearance and
glow on logs.
29)
Locate the ground lug at the receptical
box, left of the unit.
30)
Connect one end of the supplied green
ground wire to the lug with the nut and
washer from the kit.
31)
Install the 1/2" bushing to the heat
shield.
Ground
wire from
kit
33)
Plug the DC spark generator wires to the
DC Sparker.
34)
Connect the ground wire to the DC Sparker
mounting bracket.
36)
Mount the heat shield to the DC Sparker.
Secure into place with the velcro, which
is provided in the kit.
Heat Shield
32)
Run the other end of the ground wire
and DC spark generator wires through
the bushing on the heat shield.
38)
Tie up the loose wire with the wire clip.
Chain
37a)
Find a location which is not too hot and
is easy to reach for changing the battery.
Note:
It should be kept away from the
chain.
37b)
Recommended location to mount the
DC
Sparker.
37c)
Note:
Remove the bottom louver by
unscrewing the four screws located on
the hinges.
35)
Install the supplied battery into the DC
Sparker Box by opening the battery
compartment.
NOTE:
The battery in the DC Sparker
Box will need to be replaced annually.
Battery
Compartment
INSTALLATION