![Regency E18E-LP Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/regency/e18e-lp/e18e-lp_owners-and-installation-manual_1433419076.webp)
76
|
Regency
®
E18E Gas Fireplace Insert
|
76
maintenance
IMPORTANT
Disconnect power supply
before servicing.
REMOVING THE FAN
1. Shut off the gas and electrical supply.
2.
Remove Control Cover. (see instructions in manual)
3.
Remove Glass Door.(see instructions in manual)
4.
Remove Log Set and Embers or crystals and stones (if installed).
5.
Remove Burner and Panels (see instructions in manual)
6.
Remove Valve Tray - see previous page.
7.
Disconnect Ground Wires and unclip Safety Circuit Wires and remove
through Grommet .
8.
Loosen 4 screws holding in Air Inlet Baffle and remove it.
9.
Loosen 3 screws holding in the Circulation Fan.
10
. Disconnect Power Leads on Fan Motor
11.
Reverse Steps to reinstall.
Diagram 20.1
Diagram 20.2