RC500EX
|
41
installation
Min. 12"*
(305mm)
Snorkel
**
Riser Vent
Termination
Min. 6-1/4"*
(159mm)
CL
center
of hole
Centerline
40-5/16" (1022mm)
CL
center
of hole
Centerline
49-1/2" (1257mm)
You will require the following components with your
new Direct Vent Freestanding Gas Stove. Please
review your product to make sure you have every
-
thing you need. In the event that you are missing
any part, contact your dealer.
Note: These are the minimum pieces
required. Other parts may be
required for your particular instal
-
lation. See above for a list of vent
parts.
If installing termination on a siding covered wall,
a vinyl siding standoff or furring strips can be
used in order to ensure that the termination is not
recessed into siding.
The vinyl siding standoff is required for walls with
vinyl siding.
Minimum components for a Dura-Vent
Horizontal Installation:
A) Dura-Vent Horizontal Termination Kit
B) Wall Thimble (required for combustible walls)
Minimum components for a Dura-Vent
Vertical Termination:
D) Dura-Vent Vertical Termination Kit. See above
for pipe lengths.
Diagram 2a
Horizontal Terminations
1. Set the unit in its desired location. Check to
determine if wall studs are in the way when
the venting system is attached. If this is the
case, you may want to adjust the location of
the unit.
a)
The horizontal run of vent should have a
1/4 inch rise for every 1 foot of run towards
the termination. Never allow the vent to run
downward. This could cause high temperatures
and may present the possibility of a fire.
b)
The location of the horizontal vent termina
-
tion on an exterior wall must meet all local
and national building codes, and must not be
blocked or obstructed. Refer to the "Exterior
Vent Terminal Locations" section.
c)
Snorkel Terminations:
For installations requiring a vertical rise on the
exterior of the building, 14-inch and 36-inch
tall Snorkel Terminations as shown in Diagram
2 are available, as well as the standard Riser
Vent. Follow the same installation procedures
as used for standard Horizontal Termination.
NEVER install the snorkel upside down.
Diagram 1a
Diagram 1
*Diagram 2a: As specified in CGA B149 Installation
Code. Local codes or regulations may require dif
-
ferent clearances.
Diagram 2b
NOTE:
For Snorkel terminations in ABOVE
grade installations, follow national
or local code requirements.
Below Grade Snorkel Installation
If the Snorkel Termination must be installed below
grade, i.e. basement application, proper drainage
must be provided to prevent water from entering
the Snorkel Termination. Refer to Installation in
-
structions for details.. Do not attempt to enclose
the Snorkel within the wall, or any other type of
enclosure.
Diagram 3
Rear vented
Vertical rise with a minimum of 90
degree elbow installed.
2. Assemble the desired combination of pipe and
elbow to the appliance adapter with pipe seams
oriented down. Offset the pipe seams as double
seams in one place will cause the outer pipe to
take an oval shape.
3. With the pipe attached to the stove, slide the
stove into its correct location, and mark the
wall for a 9-1/2" (inside dimensions) round
hole. The center of the round hole should line
up with the centerline of the horizontal pipe, as
shown in diagram 1. Cut and frame the 9-1/2
round hole in the exterior wall where the vent
will be terminated. If the wall being penetrated
is constructed of non-combustible material, i.e.
masonry block or concrete, a 7" diameter hole
is acceptable.
**Note: Riser vent is only for use in above-grade
terminations.
4. Install wall penetration heat shield in the center
of the 9-1/2" round hole and attach with wood
screws. The four wood screws provided should
be replaced with appropriate fasteners for
stucco, brick, concrete, or other types of sid
-
ings. Diagram 3.
5. If installing termination on a siding covered
wall, a vinyl siding standoff or furring strips
must be used to ensure that the termination
is not recessed into the siding. See diagram 3.
(305 mm)
Min. 12”
Window
Well
Adequate
Drainage
Gravel
Snorkel
Diagram 2c