Regency Bellavista™ B41XTCE-10 Gas Fireplace
|
45
|
45
installation
OPTIONAL FAN INSTALLATION
919-425
08/21/14
1
FAN INSTALLATION
B41XTCE / B41XTE
Important:
120 Volt AC power is needed for the blower. The
receptacle box will be installed on the left hand side of the unit and
will need to be wired by a qualifi ed electrician prior to fan assembly
being installed. The neutral (wider) slot of the polarized receptacle
should be at the top.
Unit must be grounded at all times. Do not cut the ground termi-
nal off under any
circumstances.
1.
Shut the power off.
2.
Remove the mesh barrier and standard fl ush door.
3.
Remove fan assembly from box, locate green ground wire and
pull out of fan assembly - taking care not to damage or cut wire
casing.
4.
Connect the
Black
wire to the left side terminal of the fan motor.
Slide the black wire and the green ground wire into grommet and
push grommet into the fan assembly housing.
5.
Connect the
White
wire onto the right side terminal of the fan motor,
Connect the red wire into the grommet and push grommet into the
fan assembly housing.
BLACK
WHITE
6.
Position the fan base with the motor end towards the rear of the
fi rebox and then slide the fan in towards the rear of the unit. Turn
the fan housing slightly to the left and make the fan assembly paral-
lel to the rear wall.
7.
Lift the fan housing upwards and slip it over the two mounting pins
(use of dish soap will help the rubber grommets slide down over the
pins).
8.
Connect and secure fan ground cable to ground lug.
NOTE:
If optional accent lights are installed,take care when sliding the
fan into position. Fan must be maneuvered around the right
side of the light.
Push Fan down
on mounting pins
Electrical
Receptacle
Ground Lug
Plug fan power cord
into
receptacle.
rear
Mounting Pins