Bellavista® B36XTE-10 Gas Fireplace
|
35
|
35
installation
HORIZONTAL TERMINATIONS
TWO (2) 90
O
ELBOWS (RIGID PIPE 4" X 6 - 5/8")
H
H1
V
Option V
H + H1
A)
0' Min. 2' Max.
B)
1' Min. 3' Max.
C) 2' Min. 4' Max.
D) 3' Min. 5' Max.
E)
4' Min. 6' Max.
F)
5' Min. 7' Max.
G) 6' Min. 8' Max
With these options,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
One 90
o
elbow = Two 45
o
elbows.
Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994.
No Vent Restrictor Installed
HORIZONTAL TERMINATIONS
THREE (3) 90
O
ELBOWS (RIGID PIPE 4" X 6 - 5/8")
V1
H1
H
V
Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994.
Option V
H V + V1 H + H1
A)
0' Min. 1' Max. 1' Min. 2' Max.
B)
1' Min. 2' Max. 3' Min. 3' Max.
C) 2' Min. 2' Max. 5' Min. 4' Max.
D) 3' Min. 2' Max. 7' Min. 5' Max.
E)
4' Min. 3 Max. 9' Min. 6' Max.
F)
5' Min. 4' Max. 10' Min. 7' Max.
G) 6' Min. 5' Max. 11' Min. 8' Max.
H) 7' Min. 6' Max. 12' Min. 9' Max.
With these options,
max. total pipe length
is 30 feet with min. of
12 feet total vertical
and max. 9 feet total
horizontal.
Please note min. 1
foot between 90
o
elbows is required.
One 90
o
elbow = Two 45
o
elbows.
No Vent Restrictor Installed