INSTALLING THE OPTIONAL FAN
919-424
10.06.14
1
FAN INSTALLATION
B36XTCE / B36XTE
7
. Plug in the fan power cord to the Fan
Control Module into the outlet marked
“Fan”. Disconnect the A/C adapter from
the FC-COM wire (If installed) and remove.
Plug the FCM-COM wire from the remote
control wiring harness into the location on
the Fan Control Module marked “COM”.
Turn the switch on the Fan Control Module
to the ON position. ON is to the left. The
“O” is the off position
8
. See the Proflame instructions for coding
the remote handheld to the receiver and
for operating instructions.
9
. Reverse Steps 2 -1 to complete the instal-
lation.
Important:
120 Volt AC power is needed
for the blower. The receptacle box will be
installed on the left hand side of the unit and
will need to be wired by a qualified electrician
prior to fan assembly being installed. The
neutral (wider) slot of the polarized receptacle
should be at the top.
Unit must be grounded at all times. Do not
cut the ground terminal off under any
circumstances.
1.
Shut the power off.
2.
Remove the mesh barrier and standard
flush door
Diagram 2
Diagram 3
Diagram 4
Push Fan down
on mounting pins
Electrical
Receptacle
Ground Lug
Plug fan power cord
into
receptacle.
rear
Mounting Pins
5.
Slide the thermodisc/cover assembly into
the bracket clip on the underside of the
firebox. Check that no wire will touch the
hot surfaces. Diagram 3 and 4.
6.
Install the Fan Control Module (FCM) on
to the left side base of the unit and plug in
to electrical receptacle in unit as shown.
4.
Connect fan ground cable to ground lug.
Refer to wiring diagram.
3.
Turn the fan base on its side (with the
base facing towards you) and then slide
the fan in towards the rear of the unit. Turn
the fan upright and slip it over the two
mounting studs. Take care not to damage
the insulation on the fan base. Ensure that
the fan blades do not rub against the valve
tubing.
FCM-COM Wire
Fan Power Cord
FCM-COM Wire
TO REMOVE THE FAN
1)
Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for life.
Do not lubricate them. Make sure you
vacuum the fan area on a regular basis.
IMPORTANT:
These fans collect a lot of dust from within
your home. Ensure you maintain these fan
motors on a regular basis by vacuuming
out the fan blades and housing using a
soft brush nozzle.