B41XTCE Gas Fireplace

Model

B41XTCE-NG11

B41XTCE-LP11

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C./C.E. (1.25 kPa)

11” W.C./C.E. (2.74 kPa)

Manifold Pressure - High

3.5” W.C./C.E. (0.87 kPa)

10” W.C./C.E. (2.49 kPa)

Manifold Pressure - Low

1.6” W.C./C.E. (0.40 kPa)

6.4” W.C./C.E. (1.60 kPa)

Orifice Size -

Altitude 0-4500 ft.

#30 DMS 

#49 DMS 

Minimum Input  

Altitude 0-4500 ft. (0-1372m)

30,000 BTU/h  

(8.79 kW)

29,500 BTU/h 

(8.65 kW) 

Maximum Input 

Altitude 0-4500 ft. (0-1372m)

42,500 BTU/h 

(12.45 kW)

37,500 BTU/h 

(10.99 kW)

CSA P.4.1

68.15%

68.35%

Q

P

U V

T

Opening for gas

connection

11" (279mm)

dia. Hole through

wall Vent.

Non-Combustible

Header

(steel stud) on edge

Drywall

(or other

facing)

W

Non-Combustible Facing

S

S

R

Non-combustible

Header

(steel stud

on edge)

M

N

L

O

** Important:  Framing height requires consideration of the hearth depth.  

   Dimension N = N + the thickness of the installed hearth.

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Direct Vent Pro®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
ICC Excel Direct Vent

28-

1/2"

38-3/8"

22-1

1/16"

46-11/16"

25-9/16"

16-7/16"

32-5/8"

38-1/4"

36-3/8"

26-3/16"

3-1/4"

49-

1/4

"

11-

5/8"

7-5/16"

1-9/16"

1-1/2"

35"

44-1/4"

3-5

/8"

29-

1/8"

23-7/16"

38-7/16"

[1185mm]

[974mm]

46-11/16"

[1185mm]

[976mm]

[889mm]

[7

38m

m]

[92

mm

]

[594mm]

[649mm

]

[664mm]

[1

251

mm

]

[38mm]

[1

123mm]

[417mm]

[82

9mm

]

[185mm]

[294mm]

[7

24m

m]

[39

m

m]

[92

3m

m]

[97

1mm]

[576mm

]

Framing 

Dimensions

Description

B41XTCE

M

Framing Width

47-1/4"(1200mm)

N

Framing Height

49-1/2" (1257mm)

O (Rear Vent)

Framing Depth - Rear Vent

26-1/2" (673mm) 

O  (Top Vent)

Framing Depth - Top Vent

25-7/8" (657mm) 

P  

Corner Facing Wall Width

65-1/4" (1657mm)

Q  

Corner Facing Wall Width

91-11/16" (2329mm)

R (Rear Vent)

Framed Chase Ceiling - Rear

49-1/2" (1257mm)

R (Top Vent)

Framed Chase Ceiling - Top

54-1/2" (1384mm)

S  (Rear Vent)

Vent Centerline Height - Rear

28-1/2" (724mm)

S  (Top Vent) 

Vent Centerline Height - Top

47-1/2" (1207mm) Rigid / Flex

T

Gas Connection Height

1-1/2" (38mm)

U

Gas Connection Inset

5" (127mm)

V

Gas Connection Width

3-1/4" (82mm)

W

Non-Combustible Top Height

6" (152mm)

Gas Fireplaces

Содержание B41XTCE-NG11

Страница 1: ...Systems FPI AstroCap Flex Vent Rigid Pipe Vent Systems Simpson Direct Vent Pro Selkirk Direct Temp Metal Fab Sure Seal ICC Excel Direct Vent 28 1 2 38 3 8 22 11 16 46 11 16 25 9 16 16 7 16 32 5 8 38 1 4 36 3 8 26 3 16 3 1 4 49 1 4 11 5 8 7 5 16 1 9 16 1 1 2 35 44 1 4 3 5 8 29 1 8 23 7 16 38 7 16 1185mm 974mm 46 11 16 1185mm 976mm 889mm 738mm 92mm 594mm 649mm 664mm 1251mm 38mm 1123mm 417mm 829mm 18...

Страница 2: ...ired clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Mantel Height min 17 9 16 446mm Top of Fireplace Opening B Sidewall 9 229mm Side of Fireplace Opening C Ceiling 36 5 8 930mm Top of Fireplace Opening D Mantel Depth max 12 304mm 25 13 16 6...

Страница 3: ... made of metal studs covered with a non combustible board The non combustible mantel when installed at a lower overall height may not be lower than 6 inches from the top of the fireplace opening Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12 1 7 A B C Non combustible Header steel stud on edge 14 To Floor 12 24 Inches D 6 Non combustible Standoff Mantel Clearances B41XT...

Страница 4: ...shing material tile slate etc the material can be installed directly onto the metal surface clean front of the unit in the area shown below CLEAN FINISH 6 If applying a non combustible facing it may be installed over the metal surface clean front of the unit in the area shown below Combustible and Non combustible Facing and Finishing Materials around unit 38 7 16 976mm 29 737mm Combustible Materia...

Страница 5: ...ough edges may be visible from an angle To maintain a clean finished edge facing material edges may be finished with a J style trim or metal corner bead both materials available at your local building or hardware store IMPORTANT Materials used must be NON COMBUSTIBLE IMPORTANT FINISHING DETAIL NOTE Before placing unit into final position it is important to know the total thickness height of finish...

Страница 6: ...ipe Venting Systems for Propane and Natural Gas Two 45o elbows equal to one 90o elbow Maximum of four 45o elbows allowed Vent must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles as listed in the Clearances section Refer to the Vent Restrictor Position section for details on how to change the vent restrictor...

Отзывы: