background image

Regency Hume Freestanding Wood Fire

8

OPERATING INSTRUCTIONS

4)

  After about 45 minutes, when your wood 

has begun to burn strongly, adjust your draft 
control down to keep the fi re at a moderate 
level.

 

WARNING:  Never build a roaring fi re in 
a cold stove.  Always warm your stove 
up slowly!

5)

  Once a bed of coals has been established 

on the base of the fi rebox, you may adjust 
the draft control to a low setting to operate 
the unit at its most effi cient mode.

6)

 During 

the 

fi rst few fi res, keep the combus-

tion rate at a moderate level and avoid a 
large fi re. Only after 5 or 6 such fi res can 
you operate the stove at its maximum 
setting, and only after the metal has been 
warmed.

7)

 For the fi rst few days, the stove will give 

off an odour from the paint. This is to be 
expected as the high temperature paint 
becomes seasoned. Windows and/or doors 
should be left open to provide adequate 
ventilation while this temporary condition 
exists.   Burning the stove at a very high 
temperature the fi rst few times may damage 
the paint. Burn fi res at a moderate level the 
fi rst few days.

8)

  Do not place anything on the stove top 

during the curing process. This may result 
in damage to your paint fi nish.

Pull - Open

WARNING:  To build a fi re in ignorance 
or to disregard the information con-
tained in this section can cause serious 
permanent damage to the unit and void 
your warranty!!

AIR SLIDE CONTROL

Both the primary and air wash drafts are control-
led by the control rod located on the right side 
of the unit (when facing the unit). To increase 
your draft - pull open, and to decrease - push 
closed.  All units have a secondary draft system 
that continually allows combustion air to the 
induction ports at the top of the fi rebox,  just 
below the fl ue baffl e.  

OPERATING 

INSTRUCTIONS

With your unit now correctly installed and safety 
inspected by your local authority, you are now 
ready to start a fi re.  Before establishing your 
fi rst fi re, it is important that you fully understand 
the operation of your draft control.

CAUTION: THIS APPLIANCE MUST BE 
MAINTAINED AND OPERATED AT ALL TIMES 
IN ACCORDANCE WITH THESE INSTRUC-
TIONS.

CAUTION: THE USE OF SOME TYPES OF 
PRESERVATIVE-TREATED WOOD AS A FUEL 
CAN BE HAZARDOUS.

WARNING: ANY MODIFICATION OF THE AP-
PLIANCE THAT HAS NOT BEEN APPROVED 
IN WRITING BY THE TESTING AUTHORITY 
IS CONSIDERED AS BREACHING AS/NZS 
4013.

WARNING: DO NOT USE FLAMMABLE 
LIQUIDS OR AEROSOLS TO START OR 
REKINDLE THE FIRE.

WARNING: DO NOT USE FLAMMABLE LIQ-
UIDS OR AEROSOLS IN THE VICINITY OF 
THIS APPLIANCE WHEN IT IS OPERATING.

WARNING: DO NOT STORE FUEL WITHIN 
HEATER INSTALLATION CLEARANCES.

WARNING: OPEN AIR CONTROL (AND 
DAMPER WHEN FITTED) BEFORE OPENING 
FIRING DOOR.

For safety reasons and in order to avoid 
over fi ring of your unit do not burn your 
fi re with the door open or ajar.

FIRST FIRE

When your installation is completed and in-
spected you are ready for your fi rst fi re.

1)

  Open control fully.

2)

 Open 

fi rebox door and build a small fi re us-

ing paper and dry kindling on the fi rebrick 
hearth.  Secure door on the fi rebox and wait 
a few minutes for a good updraft in the fl ue to 
establish the fi re.  (Leaving the door slightly 
open will help your fi re start more rapidly.)

 

CAUTION:  Never leave unit unattended 
if door is left open.  This procedure is for 
fi re start-up only, as unit may overheat 
if door is left open for too long.

3)

  With the draft still in the fully open position 

add two or three seasoned logs to your  fi re. 
Form a trench in the ash bed to allow air to 
reach the rear of the fi rebox prior to closing 
the door.

Push - Closed

Содержание Albany F200B-1

Страница 1: ...or property damage Refer to this manual For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier HUME FREESTANDING W...

Страница 2: ...manual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction sh...

Страница 3: ...ance 9 Door Latch Adjustment 9 Wood Storage 9 PARTS LIST Stove Assembly 10 WARRANTY Warranty 11 Data Badge 4 Unit Dimensions 5 INSTALLATION Residential Installation 6 Safety Guidelines and Warnings 6 Brick Cast Installation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 ...

Страница 4: ...is the correct one Regency Freestanding Wood Fire Model Hume F250B TESTED TO AS NZS 4013 1999 TEST REPORT NUMBER HCMG 07 003 13kW 57 WHEN TESTED IN ACCORDANCE WITH AS NZS 4012 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2012 2013 2014 Fireplace Products Australia Pty Ltd 21 23 South Link Dandenong VIC 3175 TESTED BY HRL TECHNOLOGY PTY LTD TRAMWAY ROAD MORWELL VICTORIA 3840 2007 MAXIMUM AVERAGE...

Страница 5: ...Regency Hume Freestanding Wood Fire 5 UNIT DIMENSIONS ...

Страница 6: ...s preventsmoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverfiring Stopaddingfueland close the draft control Overfiring can cause extensive damage to your stove including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot build up in the chimn...

Страница 7: ...ot less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 Flo Met Super Single 1 Hawkwind Standard AHD Special Insulated 2 IMPORTANT 1 The Flomet Super Single flue kit must be installed with a 130o x 900mm stainless reflective shield between decromesh 2 The AHD Special Insulated flue kit must be installe...

Страница 8: ... ports at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THE...

Страница 9: ... an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply freshwood Thisallowsthe...

Страница 10: ...1 Top Plate Panel 6 1172004 Rear Panel 7 8010301 Bricks Set Set 9 8 8010302 Liner Cast Iron Set 9 8010303 Liner Cast Iron Sides L R 10 8010305 Liner Cast Iron Back 11 8010306 Air Bar Stainless Steel 12 8010307 Glass Neoceram With Gasket 13 8010313 Door Assembly without handle 14 8010309 Air Slide 15 8010310 Ash Lip Panel 16 8010114 Door Handle Set 17 F250 917 Fan Assembly 18 1172003 Pedestal Assem...

Страница 11: ...cy Fireplace Products will not be liable for results or costs of workmanship from unauthorised service persons or dealers At all times Regency Fireplace Products reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to Regency Fireplace Products by authorized selling dealers It is essential that all submitted claims provide all of the nece...

Страница 12: ...PLACE PRODUCTS AUSTRALIA PTY LTD 21 23 SOUTH LINK DANDENONG SOUTH VICTORIA 3175 AUSTRALIA NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...