Regency 600PHSPUMP Скачать руководство пользователя страница 5

5

TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

The pump does 

not start or run.

The fuse is blown

Replace the fuse

The breaker is tripped

Reset the breaker

The plug is disconnected

Secure the plug

The plug is corroded

Clean the plug prongs

The brushes are worn

Replace the brushes

The motor is overheated

Unplug from power and wait for 30 minutes, 

then plug power cord back in

The pump does 

not prime

The suction line is leaking air

Repair the suction line by tightening hose 

connection or replacing hose washer if 

necessary

The impeller is clogged

Remove the blockage

The impeller is worn or 

damaged

Replace the impeller

The impeller is dry

Add water to the pump inlet

The flow rate is 

too low

The hose is kinked or coiled

Straighten the hose

The strainer or hose is blocked

Clean the strainer or hose

The discharge hose is too long

Shorten the hose (50 ft. max.)

The impeller is worn

Replace the impeller

Содержание 600PHSPUMP

Страница 1: ...WATER PUMP FOR PORTABLE SINKS USER MANUAL 600PHSPUMP REGENCYTABLESANDSINKS COM 07 2021 TRANSFER PUMP ...

Страница 2: ... the National Electrical Code and local codes and ordinances All wiring should be performed by a qualified electrician 10 Protect the electrical cord from sharp objects hot surfaces oil and chemicals Avoid kinking the cord Do not use damaged or worn cords 11 Failure to comply with the instruction and designed operation of this unit may void the warranty ATTEMPTING TO USE A DAMAGED PUMP can result ...

Страница 3: ...er cord inlet pipe or hose The pump must be set on a stable surface or suspended from the handle To ensure that the pump works properly keep the intake area free from sludge and dirt of all kinds The pump must be installed in a stationary position with either 1 This pump is designed to pump clear water only 2 This pump should be used for transferring clean water within the portable hand washing st...

Страница 4: ...ng the pump GFCI Protected 120V Socket 1 2 3 4 5 8 9 6 7 NOTE Do not disassemble the motor housing This motor has NO repairable internal parts and disassembly may cause leakage or dangerous electrical wiring issues NOTE Do not lift up the pump by the power cord IF THE PUMP IS NOT RUNNING PROPERLY 1 Remove the Impeller Cover Screws 1 2 Remove the Impeller Cover 2 3 Inspect the Gasket 3 and Impeller...

Страница 5: ...s then plug power cord back in The pump does not prime The suction line is leaking air Repair the suction line by tightening hose connection or replacing hose washer if necessary The impeller is clogged Remove the blockage The impeller is worn or damaged Replace the impeller The impeller is dry Add water to the pump inlet The flow rate is too low The hose is kinked or coiled Straighten the hose Th...

Отзывы: