18
Regency PG33 Gas Inbuilt
INSTALLATION
Horizontal Flueing with Two (2) 90
o
Elbows
Horizontal Flueing with Two (2) 90
o
Elbows
Horizontal Flueing with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
Option
V
H + H1
With these options,
maximum total pipe
length is 30 feet with
minimum of 6 feet total
vertical and maximum 8
feet total horizontal.
Please note minimum
1 foot between 90
o
elbows is required.
A)
0.3m Min. 0.9m Max.
B)
0.6m Min. 1.2m Max.
C)
0.9m Min.
1.5m Max.
D)
1.2m Min
1.8m Max.
E)
1.5m Min.
2.1m Max.
F)
1.8m Min
2.4m Max.
Option
H
V
H + H1 +H2
With these options,
max. total pipe length
is 30 feet with min. of
11 feet total vertical
and max. 9 feet total
horizontal.
Please note min.
1 foot between 90
o
elbows is required.
A)
0.3m Max.
0.3m Min. 0.9m Max.
B)
0.6m Max.
0.9m Min. 1.5m Max.
C)
0.9m Max.
1.5m Min.
1.8m Max.
D)
1.2m Max
2.1m Min
2.1m Max.
E)
1.5m Max
2.7m Min.
2.7m Max.
F)
1.8m Max
3.3m Min
2.7m Max.
Option
H
V
H + H1 +H2
With these options, max.
total pipe length is 30 feet
with min. of 8 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
A)
0.3m Max.
0.3m Min. 0.9m Max.
B)
0.6m Max.
0.9m Min. 1.5m Max.
C)
0.9m Max.
1.5m Min.
1.8m Max.
D)
1.2m Max
1.8m Min
2.1m Max.
E)
1.5m Max
2.4m Min.
2.4m Max.
Содержание PG33