PARTS LIST

P48-1 MAIN ASSEMBLY

         Part #       Description

         Part #       Description

1)

948-259

Door Handle

3)

948-046

Chain

4)

948-115

Spring

6)

430-129

Receptacle Box Mount

7)

910-429

Box - Receptacle

8)

910-428

Duplex Receptacle

9)

910-430

Cover - Receptacle

10) 904-687

Clamp Connector

20) 370-037

Top Nailing Strip

21) 370-038

Side Nailing Strip

22) 370-015

Baffle Plate

23) 780-011

Standoff - Top

24) 780-013

Standoff - Side/Back

27) *

Outer Flue Collar

28) *

Inner Flue Collar Assy

29) *

Flue Mounting Plate

30) *

Gasket for Flue Collar

35) *

Thermodisc Bracket

38) 910-241

Switch - Burner ON/OFF(3-way)

910-899

Wire Harness-Valve to Burner

432-917

Fan & Speed Control Assy (120 Volts) Optional

42) 910-331/P Fan Motor

432-966

Fan Switch Assy (120 Volts) Optional

43) 910-813

Power Cord (120 Volts)

46) 910-330

Fan Speed Control Switch

47) 904-586

Knob - Speed  Control

48) 910-199

Wire Holder Clip

49) 910-142

Thermodisc - Fan (Auto ON/OFF)

910-845

Wire Harness - Plug In Fan

50) 770-994

Optional Dura-Vent Adaptor

51) 902-331

Brick Panel - Base Center

52) 902-332

Brick Panel - Base Left

53) 902-333

Brick Panel - Base Right

370-928

Brick Panel Set - Standard

54) 902-334

Brick Panel - Back

55) 902-335

Brick Panel - Left

56) 902-336

Brick Panel - Right

57) 902-582

Brick Panel - Top

370-945

Herringbone Brick Panel Set

902-364

Herringbone Brick Panel - Back

902-365

Herringbone Brick Panel - Left

902-366

Herringbone Brick Panel - Right

902-583

Heringbone Brick Panel - Top

370-901

Brick Panel Set - Standard Brown

370-902

Brick Panel Set - Standard Red

370-903

Brick Panel Set - Herringbone Brown

370-904

Brick Panel Set - Herringbone Red

946-556

Optional Heat Wave Duct Kit

89) 946-004

Junction Box

90) 946-000

Round Duct Adaptor

91) 946-002

Round to Oval Adaptor

92) 946-001

Oval Duct Adaptor

93) 946-007

Angle Bracket

94) 946-517/P Fan Assembly - HeatWave Option
95) 946-006

Grill Plate - White

96) 946-005/01 Wall Adaptor Plate - White
97) 910-417

Knob - White

98) 910-366

Switch Cover Plate - White

99) 910-412

Fan Speed  Controller

100) 910-367

Box - Plastic Switch Receptacle

101) 690-022

Cover Plate - Outer Box Side

102) 946-010

Flexible Air Duct

946-011

Insulation 6" dia. x 24"

946-570

Heat Release Duct Kit (Optional)

105) 910-165

Fan (120 Volts)

106) 946-000

Flexible Air Release Duct

370-969

Conversion Kit - NG to LP

918-458

Manual

*Not available as a replacement part.

All manuals and user guides at all-guides.com

Содержание P48-1

Страница 1: ...st be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use...

Страница 2: ...e current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance installation...

Страница 3: ...Label SafetyLabel 4 Installation ImportantMessage 5 Before You Start 5 GeneralSafetyInformation 5 Installation Checklist 5 ManufacturedMobileHome AdditionalRequirements 6 Unit Specifications 6 Locatin...

Страница 4: ...stantly being im proved Check the label on the unit and if there is a difference the label on the unit is the correct one SAFETY LABEL Copy of Safety Decal for P48 NG1 and P48 LP1 For the State of Mas...

Страница 5: ...OTE must be done before installing unit into fireplace 3 Install venting pages 20 21 4 Make gas and electrical connections Test the pilot Must be as per diagram Page 23 5 Test Gas Pressure Page 23 6 I...

Страница 6: ...4 The P48 1 Direct Vent Gas Fireplace can beinstalledinarecessedpositionorframed out into the room as in A B C D See Diagram 1 HEARTH A hearth is not mandatory but is recommended for aesthetics and f...

Страница 7: ...0 0mm Side 0 0mm Floor 0 0mm Minimum Clearance from Top of Front Facing Mantel min 8 203mm Ceiling 39 990mm from top of front facing above louvers Side Wall 6 152mm Horizontal Vent Clearances Top 2 1...

Страница 8: ...al studs covered with a non combustible board This drawing is to scale at 1 6 one inch 6 inches Mantel can be installed anywhere in shaded area using the above scale for units with the Flush Front and...

Страница 9: ...to the same degree as the rest of the house apply vapour barrier and drywall as per local installation codes Do not insulate the fireplace itself 4 The unit does not have to be completely enclosed in...

Страница 10: ...lipped into position TopStandoffAssembly The top standoffs are shipped in a flat position and must be folded into shape and attached 1 Remove the standoffs from the fireplace top 2 Take each standoff...

Страница 11: ...ide corner 13 33cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent outlet min 36 90cm K Cle...

Страница 12: ...crews 8 x 1 1 2 Drill Point Stainless Steel 4 10 vinyl siding standoff If longer runs are needed the Regency Direct Vent system Flex Part 946 616 includes all the parts needed to install the P48 1 wit...

Страница 13: ...ches Flat Wall Installation Wall Thickness Vent Length inches Required inches 4 5 1 2 none 7 8 1 2 6 10 11 1 2 9 9 14 1 2 12 15 23 1 2 11 14 5 8 Adj Pipe Alternate Horizontal Termination Caps Part Des...

Страница 14: ...pter Part 770 994 when using Simpson Dura Vent pipe Refer to page 13 Simpson Dura Vent 5 inner diameter 8 outer diameter Regency Flex Vent 5 inner diameter 8 outer diameter Maintain clearances to comb...

Страница 15: ...E 5 Max 9 Min 8 Max F 6 Max 11 Min 9 Max With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90o elbo...

Страница 16: ...h min of 6 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is re quired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Mi...

Страница 17: ...feet total horizon tal Please note min 1 foot between 90o elbows is re quired Vertical Venting with Three 3 90o Elbows Option H V H H1 V V1 A 1 Max 1 Min 3 Max 3 Min B 2 Max 2 Min 4 Max 5 Min C 3 Max...

Страница 18: ...tional flue adapter when using Simpson Dura Vent pipe Part 510 994 VENTING ARRANGEMENTS VERTICAL TERMINATIONS SIMPSON DURA VENT DIRECT VENT GS SYSTEM Propane Natural Gas The shaded area in the diagram...

Страница 19: ...ea in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura Vent Direct Vent GS vent systems for Propane and Natural Gas Maximum two 4...

Страница 20: ...et in its desired location otherwise the unit will not fit through the 36 5 8 930mm high frame opening 3 Put a bead of silicone inside the outer section of the adapter and a bead of Stove Mate on the...

Страница 21: ...ate the appliance or to offset as shown in Diagram 2 to avoid cutting loadbearingmem bers 3 A Firestop spacer must be installed in the floor or ceiling of every level To install the Firestop spacer in...

Страница 22: ...e gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termination and mark wall according ly Cut a 11 279mm hole...

Страница 23: ...copper lines and flex connectors are usually considered to meet this requirement Important Always check for gas leaks with a soap and water solution or gas leak detector Do not use open flame for leak...

Страница 24: ...e sure the tabs of the top bracket fit into the baffle openings refer to Diagrams 6 7 The back of the top brick panel sits on top of the bottom clips 3 Insert the back brick panel first by carefully s...

Страница 25: ...nd unwrap them The logs are fragile handle with care do not force into position 3 Line up the two holes on the underside of Log 02 88 with the 2 pins at the rear of the grate and position into place 4...

Страница 26: ...Line up the hole on the underside of Log 02 84 with the pin on Log 02 86 and position the notch on the bottom of the log into the last grate post 02 84 02 83 02 86 02 88 Pin in Log Last Grate Post 02...

Страница 27: ...the log Position the cut out onto the grate bar 11 Place Log 02 87 on the middle left side of the burner Position the bottom rear of the log against the rear tab on the left side of the grate Rest th...

Страница 28: ...r reverse the above steps Diagram 1 Diagram 2 FLUSH LOUVERS 1 Install the top louver by sliding the two bracket clips into the brackets located un derneath the top of the firebox 2 Install the bottom...

Страница 29: ...are different OPTIONAL BAY DOOR The Bay louvers MUST be used with the Bay glass option The optional Bay door is an overlay on the flush front The standard flush door and glass must remain on the unit...

Страница 30: ...ith 2 screws per side 3 Loosen the 3 screws in the top inside edge of the firebox 4 Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the screws Tighten the...

Страница 31: ...Regencyoffersanoptionalprogrammablether mostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not connect millivolt wall thermost...

Страница 32: ...d with the unit it is still a good idea to hardwire the terminal block in case the fan is installed at a later date However DO NOT leave this connection live until the fan is installed Caution Ensure...

Страница 33: ...will touch the hot surfaces Diagram 2 7 AttachtheFancontrolboxtothe BurnerON OFF control box Diagram 3 9 Attach the two control boxes to the bottom louver and tighten the 2 screws on the left side and...

Страница 34: ...e label This valve has been converted from NG to LPG using SIT conversion Kit Code 0 907 202 onto the valve 13 Replace yellow Natural Gas label with red Propane label 7 Remove burner orifice with a 1...

Страница 35: ...E The first fire in your stove is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time be...

Страница 36: ...of a different gauge material from the rest of the firebox and body Therefore the varying thicknesses of steel will expand and contract at slightly differ ent rates which can cause ticking and crack...

Страница 37: ...of burner for proper position and condition Visually check the flame of the burner periodically making sure the flames are steady not lifting or floating If there is a problem call a qualified service...

Страница 38: ...licensed or qualified service per son GLASSREPLACEMENT In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Replacement glass is shipped al...

Страница 39: ...assembly out Slide the burner to the left and lift out Grate Remove the screw on the left side of the burner Right Side Deflector Left Side Deflector 11 Disconnect the 2 TP wires and the 2 TH wires f...

Страница 40: ...902 333 Brick Panel Base Right 370 928 Brick Panel Set Standard 54 902 334 Brick Panel Back 55 902 335 Brick Panel Left 56 902 336 Brick Panel Right 57 902 582 Brick Panel Top 370 945 Herringbone Bric...

Страница 41: ...T 42 48 49 46 24 105 106 101 20 21 21 24 27 30 28 30 29 50 23 23 22 97 98 100 99 95 96 93 89 92 90 102 91 93 94 47 38 43 35 4 3 1 8 7 9 10 6 HEAT WAVE DUCT KIT HEAT WAVE DUCT KIT DOORS LOUVERS PLEASE...

Страница 42: ...embly Gasket 69 904 662 27 Orifice N G 904 434 47 Orifice Propane 936 170 Orifice Gasket 75 Valve Access Plate 79 370 535 Burner Assembly 82 370 019 Burner Grate Assembly 90 910 421 Pilot ON OFF Exten...

Страница 43: ...Door Frame 139 936 155 Glass Gasket Tadpole 140 948 042 Spring Hinge 370 944 Finishing Trim Black 370 946 Finishing Trim Steel 141 Trim Side Left 142 Trim Side Right 143 TrimTop 150 Flush Glass Trim 3...

Страница 44: ...anel Set Standard Brown 370 906 Bay Brick Panel Set Standard Red 113 370 086 Bay Door Trim Each Black 370 936 Bay Door Trim Set Gold 370 934 Bay Door Trim Set Steel 370 938 Bay Louvers Set Black 370 9...

Страница 45: ...________________________________________ ______________________________________________________ _______________________________________________________________ ________________________________________...

Страница 46: ...________________________________________ ______________________________________________________ _______________________________________________________________ ________________________________________...

Страница 47: ...an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement pa...

Страница 48: ...____ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it...

Отзывы: