14
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
INSTALLATION
REGENCY
®
MANTEL LEG CLEARANCES
Combustible mantel leg clearances as per diagram:
Maximum 1-1/2" projection
at 2" minimum clearance.
REGENCY
®
SERIES COMBUSTIBLE MANTEL CLEARANCES
Because of the extreme heat this fi replace emits, the mantel clearances are critical.
Combustible mantel clearances from top of unit are shown in the diagram below.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible
board.
These drawings are to scale at 1:6 (one inch = 6 inches)
Mantel can be installed anywhere in shaded area or higher using the above scale.
Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint
may discolour.