INSTALLATION

IMPORTANT MESSAGE  

SAVE THESE 

INSTRUCTIONS

The P33-NG4 or P33-LP4 Direct Vent Fireplace 
must be installed in accordance with these 
instructions. Carefully read all the instructions 
in this manual fi rst. Consult the "authority 
having jurisdiction" to determine the need for 
a permit prior to starting the installation. It is 
the responsibility of the installer to ensure 
this fi replace is installed in compliance with 
manufacturer's instructions and all applicable 
codes.

BEFORE YOU START

Safe installation and operation of this appliance 
requires common sense, however, we are 
required by the Canadian Safety Standards 
and ANSI Standards to make you aware of 
the following:

GENERAL SAFETY 

INFORMATION

1)

  The appliance installation must conform with 

local codes or, in the absence of local codes, 

with the current  Canadian  or  National 

Gas Codes, CAN1-B149 or ANSI Z223.1 

Installation Codes.

2)

  The appliance when installed, must be 

electrically grounded in accordance with 

local codes, or in the absence of local codes 

with the current National Electrical Code, 

ANSI/NFPA 70 or CSA C22.1 Canadian 

Electrical Code.

3)

  See general construction and assembly 

instructions. The appliance and vent should 

be enclosed.

4)

  This appliance must be connected to the 

specifi ed vent and termination cap to the 

outside of the building envelope. Never vent 

to another room or inside a building. Make 

sure that the vent is fi tted as per Venting 

instructions.

5)

  Inspect the venting system annually for 

blockage and any signs of deterioration.   

6)

  Venting terminals shall not be recessed into a 

wall or siding.

7)

  Any safety glass removed for servicing 

must be replaced prior to operating the 

appliance.

8)

  To prevent injury, do not allow anyone who 

is unfamiliar with the operation to use the 

fi replace.

9)

  Wear gloves and safety glasses for protection 

while doing required maintenance.

10)

 Be aware of electrical wiring locations in 

walls and ceilings when cutting holes for 

termination.

11)

 Under no circumstances should this 

appliance be modifi ed. Parts that have to be 

removed for servicing should be replaced 

prior to operating this appliance.

12)

  Installation and any repairs to this appliance 

should be done by a qualifi ed service 

person. A professional service person 

should be called to inspect this appliance 

annually. Make it a practice to have all of 

your gas appliances checked annually.

13)

 Do not slam shut or strike the glass door.

14)

 Under no circumstances should any solid 

fuels (wood, paper, cardboard, coal, etc.) 

be used in this appliance.

15)

 The appliance area must be kept clear and 

free of combustible materials, (gases and 

other fl ammable vapours and liquids).

MANUFACTURED 

MOBILE HOME 

ADDITIONAL 

REQUIREMENTS

1)

  Ensure that structural members are not 

cut or weakened during installation.

2)

  Ensure proper grounding using the #8 

ground lug provided. Refer to "Wiring 
Diagram" Section.

INSTALLATION AND  REPAIR 
S H O U L D   B E   D O N E   B Y   A 
QUALIFIED SERVICE PERSON. 
THE APPLIANCE SHOULD BE 
I N S P E C T E D   B E F O R E   U S E 
AND AT  LEAST ANNUALLY 
B Y   A   P R O F E S S I O N A L 
S E R V I C E   P E R S O N .   M O R E 
FREQUENT CLEANING MAY BE 
REQUIRED DUE TO EXCESSIVE 
L I N T   F R O M   C A R P E T I N G , 
B E D D I N G   M AT E R I A L ,   E T C . 
I T   I S   I M P E R AT I V E   T H AT 
CONTROL COMPARTMENTS, 
BURNERS AND CIRCULATING 
A I R   P A S S A G E W AY S   O F 
T H E   A P P L I A N C E   B E   K E P T 
CLEAN.

YOUNG CHILDREN SHOULD BE 
CAREFULLY  SUPERVISED WHEN 
THEY ARE IN THE SAME ROOM 
AS THE APPLIANCE.

Emissions from burning  wood or gas could 
contain chemicals known to the State of 
California to  cause cancer, birth defects 
or other reproductive harm.

DUE TO HIGH TEMPERATURES, 
THE APPLIANCE SHOULD BE 
LOCATED OUT OF TRAFFIC AND 
AWAY FROM FURNITURE AND 
DRAPERIES.

WARNING: FAILURE TO INSTALL 
THIS APPLIANCE CORRECTLY 
WILL VOID YOUR WARRANTY 
AND MAY CAUSE A SERIOUS 
HOUSE FIRE.

C H I L D R E N   A N D   A D U LT S 
SHOULD BE ALERTED TO THE 
HAZARDS OF HIGH SURFACE 
TEMPERATURES, ESPECIALLY 
T H E   F I R E P L A C E   G L A S S , 
AND SHOULD STAY AWAY TO 
AVOID BURNS OR CLOTHING 
IGNITION.  

C L O T H I N G   O R   O T H E R 
FLAMMABLE MATERIAL SHOULD 
NOT BE PLACED ON OR NEAR 
THE APPLIANCE.   

Содержание P33-LP4

Страница 1: ...in the vicinity of this or any other appliance Installation and service must be performed by a quali ed installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not...

Страница 2: ...0 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance instal...

Страница 3: ...re You Start 6 General Safety Information 6 Manufactured Mobile Home Additional Requirements 6 Installation Checklist 7 Locating Your Fireplace 7 Unit Dimensions 7 Duct System Option 7 Combustible Man...

Страница 4: ...if there is a difference the label on the unit is the correct one SAFETY LABEL For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth...

Страница 5: ...de directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VE...

Страница 6: ...electrical wiring locations in walls and ceilings when cutting holes for termination 11 Under no circumstances should this appliancebemodi ed Partsthathavetobe removed for servicing should be replace...

Страница 7: ...and operation fully explained to customer This includes 1 Clockingtheappliancetoensurethecorrect ring rate rate noted on label after burning appliance for 15 minutes 2 Ifrequired adjustingtheprimaryai...

Страница 8: ...lated res is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this replace and vent system be installed only in accordance with these in...

Страница 9: ...nt to combustible material cannot be maintained 2 Frame in the enclosure for the unit with framing material FRAMING AND FINISHING 16 1 2 419mm Minimum 4 102mm 3 76mm 1 1 2 38mm 30 762mm 10 254mm dia H...

Страница 10: ...ount Side Nailing Strip using the 3 supplied screws into the three pre punched screw holes at the front sides of the unit Adjust support to desired facing material thickness UNIT ASSEMBLY PRIOR TO INS...

Страница 11: ...m horizontally from the centerline of the regulator J Clearance to service regulator vent outlet min 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to a...

Страница 12: ...erminal Locations Section Regency Direct Vent Flex Termination Kit Part 946 513 includes all the parts needed to install the P33 4 with a maximum run of 2 feet If installing the P33 with a continuous...

Страница 13: ...trips 3 Assemble the vent assembly by applying Mill Pac to the 4 100mm inner collar of the terminationand slippingthe4 100mm liner over it at least 1 3 8 35mm Fasten with the3screws drillingpilotholes...

Страница 14: ...nches Flat Wall Installation Max Wall Vent Length Thickness inches Required inches 7 1 4 6 10 1 4 9 13 1 4 12 12 1 4 15 7 8 11 14 5 8 Adj Pipe 18 1 4 25 1 4 11 14 5 8 Adj Pipe Alternate Horizontal Ter...

Страница 15: ...46DV 08AB 911B 4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adj...

Страница 16: ...A N A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N...

Страница 17: ...s to combustibles Note Must use optional rigid pipe adapter when using rigid vent systems Part 510 994 RIGID PIPE VENTING ARRANGEMENTS Vertical Terminations Propane Natural Gas The shaded area in the...

Страница 18: ...as The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas Maximum two 45o elb...

Страница 19: ...zontal vent must be supported every 3 feet Firestops are required at each oor level and whenever passing through a wall A vent guard should be used whenever the terminationislowerthanthespeci edminimu...

Страница 20: ...8 Max One 90o elbow Two 45o elbows Option H V H H1 H2 With these options maximum total pipe length is 30 feet with minimum of 11 feet total vertical and maximum 9 feet total horizontal P l e a s e n...

Страница 21: ...B 3 Min 2 Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 Min 8 Max F 7 Min 6 Max 12 Min 9 Max One 90o elbow Two 45o elbows Option V H V V1 With these options max...

Страница 22: ...5o elbows One 90o elbow Two 45o elbows With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please note min 1 foot between 90o elbows...

Страница 23: ...Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit which contains the following Co linear Flex Adapter Outer Pipe Inne...

Страница 24: ...AL TERMINATIONS with Co linear Flex System for both Residential Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations INSTALLATION 8 2 4m...

Страница 25: ...e unit in its desired location Check to determine if wall studs or roof rafters are in the way when the venting system is attached If this is the case you may want to adjust the location of the unit R...

Страница 26: ...venting system it is highly recommended to apply Mill Pac sealant supplied to every in ner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Sili...

Страница 27: ...STALLATION Incorrect ame pattern will have small probably yellow ames not coming into proper contact with the rear burner or thermopile or thermocouple HIGH ELEVATION This unit is approved in Canada f...

Страница 28: ...ce Installation of the LPG Conversion Kit 1 Shut off the gas supply 2 P33 4 Only a Remove the louvers and bay door if it is installed b Open the ush door and remove the door c Remove the logs embers...

Страница 29: ...en wrench as shown in Fig 4 rotate the screw clockwise until snug do not overtighten 13 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5...

Страница 30: ...is not too hot and is easy to reach for changing the battery Note It should be kept away from the chain 14 Tie up the loose wire with the wire clip Ground wire from kit Chain 1 Locate the Piezo Ignito...

Страница 31: ...instructionsbelowcarefully and refer to the diagrams If logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation Log Kit 431 930 contains the foll...

Страница 32: ...m on the front of the burner tray in the places shown in the photo below Do not compress the rock wool leave it loose Separate platinum embers and place them on the front of the burner on and around t...

Страница 33: ...Diagram 2 Note Top and bottom louvers are different 3 Open the bottom louver Pull the Burner ON OFF control box from inside the bottom of the replace and position the slots in the bracket over the 2...

Страница 34: ...stall top louver by sliding the two bracket clips into the brackets located on top of the bay door See below The tted louver leaves a small gap between faceplate bottom and louver top Bay Louver Top H...

Страница 35: ...n the inside top of the outer frame of the appliance Also remove the center screw b Slide the cut outs in the Top and Bottom Flange of the Full Screen Door Frame under the screw heads which were loose...

Страница 36: ...pping Phillips screws provided Bottom Grill Hinge Location 7 Mount the Burner ON OFF Control Box to the left side of the Bottom Grill using 2 x 8 1 4 Philips Head Screws Burner ON OFF Control Box Left...

Страница 37: ...roved may be used CAUTION Do not wire millivolt wall thermostat wires to 120V wire Thermostat Wire Table Optional REMOTE CONTROL UsetheRegency RemoteControlKit approved for this unit Use of other syst...

Страница 38: ...tat will continue to operate However a 120V A C power supply is needed for the fan blower operation Do not cut the ground terminal off under any circumstances NOTE Even if the fan is not purchased wit...

Страница 39: ...and are away from sharp edges CAUTION Labelallwires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation INSTALLATION For PROPANE Units and Units Equ...

Страница 40: ...and 1 screw on the right side Secure left side with 2 screws Secure right side with one screw Secure the 2 boxes together with one screw Hold control box assembly in place and mark the position of the...

Страница 41: ...Regency P33 4 Zero Clearance Direct Vent Gas Fireplace 41 OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS Gas Inlet OFF Gas Inlet...

Страница 42: ...all wiring is correct and enclosed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Make sure the glass in the door frame is properly positioned Never operate the appliance with th...

Страница 43: ...Also check mechanical supports such as Wall Straps or plumbers tape for rigidity GOLD PLATED or BRASS LOUVERS TRIM The 24 carat gold plated or brass nish on the louvers and trim requires little mainte...

Страница 44: ...Do not use abrasive materials Do not clean the glass when hot In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only and follow our step by...

Страница 45: ...16 wrench 7 Scrape off the old gasket from the oor of the rebox and from the valve tray assembly 8 Install a new gasket and reinstall the valve tray assembly Note Failure to install a new gasket may s...

Страница 46: ...Right Side 36 Brick Panel Top 37 430 056 Brick Clip Top 38 430 057 Brick Clip Bottom 432 917 Fan Assembly 120 Volts Optional 42 910 331 P Fan Motor 120 Volts 432 966 Fan Switch Assy 120 Volts 43 910...

Страница 47: ...Regency P33 4 Zero Clearance Direct Vent Gas Fireplace 47 PARTS LIST...

Страница 48: ...57 910 478 S I T Valve NG LP 58 Valve Bracket 59 Firebox Base 60 Valve Tray 66 910 038 Pilot Assy 3 way ame S I T NG 910 039 Pilot Assy 3 way ame S I T LP 904 568 Ori ce 44 Natural Gas 904 163 Ori ce...

Страница 49: ...ver Assy Bottom 433 538 Flush Door Assembly Complete 135 940 088 P Glass Flush 137 904 691 U Clip 139 936 155 Glass Gasket Tadpole 140 948 042 Spring Hinge Black 430 940 Finishing Trim Set Black Optio...

Страница 50: ...P Center Glass 110 Bay Door Frame 112 Bay Brick Panel Spacer 117 904 196 Magnet 1 round 118 Louver Hold Down 120 400 189 Glass Retainer 432 956 Bay Door Trim set Gold 123 Bay Door Trim each Black 430...

Страница 51: ...agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within t...

Страница 52: ...al No __________________________________________________________ Printed in Canada Regency replace products are designed with reliability and simplicity in mind In addition ourinternalQualityAssurance...

Отзывы: