INSTALLATION

1)

  Positive Flue 

 Connection 

 

with Cleanout

included with the kit.

FLUE CONNECTOR 

BRACKET

Package contains: 3 brackets and 6 screws.

These brackets are to be used to hold the flue 

liner (not supplied) to the Insert and keep the 

connection. The brackets are screwed into the 

top of the Insert in the pre-punched holes and 

then screwed into the flue liner.

INSTALLATION INTO A 

MASONRY FIREPLACE

The insert must be installed as per the require-

ments of your local inspection authority.  Three 

methods of flue connection are acceptable in 

most areas in the US,  however 

a full flue liner 

is required in Canada.

1)

  Positive  flue  connection,  where  a  large 

blocking plate and a short connector pipe 

is used.

2)

  Direct  flue  connection,  where  a  smaller 

blocking plate and a connector pipe to the 

first flue liner tile is used.

3)

  Full flue liner, where a stainless steel rigid 

or flexible liner pipe is routed from the insert 

outlet collar to the top of the chimney.

Regency highly recommends the use of a full 

liner as the safest installation and provides the 

most optimum performance.  Your retailer should 

be able to help you decide which system would 

Flush Inserts

2)

  Direct Flue 

 Connection 

 

with Cleanout

3a)

 Full Flue Liner

 

(No Cleanout Required)

be the best for your application.

Note:  A clean-out door is sometimes 

required, by your inspector, to be 

installed when either the Positive flue 

connection or Direct flue connection 

method is used.  

The use of one of the connection methods listed 

on this page not only increases the safety of your 

insert by directing the hot gases up the flue, but 

will also help increase the unit's efficiency and 

decrease creosote deposits in the chimney.

When a connected flue or liner is in use, the 

insert is able to “breathe” better by allowing a 

greater draft to be created.  The greater draft can 

decrease problems such as, difficult start-ups, 

smoking out the door, and dirty glass.

STEP-BY-STEP 

INSTALLATION INTO A 

FACTORY BUILT  

FIREPLACE

1)

  When installed in a factory built fireplace, a 

full stainless steel rigid or flexible flue liner 

is mandatory, for both safety and perform-

ance purposes.  When a flue or liner is in 

use, the insert is able to breathe better by 

allowing a greater draft to be created.  The 

greater draft can decrease problems such 

as, difficult start-ups, smoking out the door, 

and dirty glass.  

2)

  In order to position the flue liner, the exist

-

ing rain cap must be removed from your 

chimney  system.  In  most  cases  the  flue 

damper should also be removed to allow 

passage of the liner.

3)

  In most cases opening the existing spark 

screens fully should give enough room for 

the insert installation. If it does not, remove 

and store.

4)

  If  the  floor  of  your  fireplace  is  below  the 

level  of  the  fireplace  opening,  adjust  the 

insert's levelling bolts to accommodate the 

difference.  When  additional  shimming  is 

required, use non-combustible masonry or 

steel shims.

5) 

Measure approximately the alignment of 

the flue liner with the position of the smoke 

outlet hole on the insert to check for pos-

sible offset. If an offset is required, use a 

proper stainless steel unit available with the 

chimney liner.

6)

  Once the above items have been checked, 

slide your insert into position after first po

-

sitioning the flue liner and offset if required. 

(Re-install raincap at completion of installa-

tion).

NOTE: Refer to "Requirements for Installing 

Solid-fuel Inserts in Factory-built Fire-

places" section for the requirements  

for installing solid fuel inserts in factory 

built fireplaces.

Содержание I2403M

Страница 1: ...da V4G 1H4 919 051c MODELS I2403M WOOD Fireplace Insert 01 30 18 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ...ease contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be cons...

Страница 3: ...tallation 10 Installation of the Faceplate and Trim 11 Installation of the Fan blower 12 Floor Protection 13 Firebrick Assembly 13 Draft Control 13 Flue Baffle Secondary Air Tube Installation 13 Door Handle 13 Screen Door 13 First Fire 14 OPERATING INSTRUCTIONS Some Safety Guidelines 14 Wood Storage 15 Ash Disposal 15 Fan Operation 15 Creosote 15 MAINTENANCE Maintenance of Gold Plated Doors 16 Doo...

Страница 4: ... USED REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAP IDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING PIÈCES NÉCESSAIRES POUR INSTALLATION 5 5 140MM OR 6 152MM CONDUITS EN ACIER INOXYDABLE COMPOSANT FACULTATIF VENTILATEUR 142 917 CARACTÉRISTIQUES ÉLECTRIQUES NOMINALES 115 VOLTS 60 HZ 0 6 A PARE É...

Страница 5: ...Regency I2403M 5 DIMENSIONS 5 5 9 ...

Страница 6: ...anduseonlyinaccordancewithmanufactur er s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safety codes before ins...

Страница 7: ...re two or three people to move it into position The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation Convection Grills The convection grills are installed before the unit is positioned inside the fireplace Position the grill on the insi...

Страница 8: ...ARANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below H HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLE The specified floor protector should be 3 8 18mm thick material with a K factor of 0 84 The proposed alternative is 4 100mm brick with a C factor of 1 25 over 1 8 3mm mineral board with a...

Страница 9: ... creosote deposits in the chimney When a connected flue or liner is in use the insert is able to breathe better by allowing a greaterdrafttobecreated Thegreaterdraftcan decrease problems such as difficult start ups smoking out the door and dirty glass STEP BY STEP INSTALLATION INTO A FACTORY BUILT FIREPLACE 1 When installed in a factory built fireplace a full stainless steel rigid or flexible flue...

Страница 10: ... bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through the door openi...

Страница 11: ... The unit may now be slid into final position and attached to the connection system 5 Onceconnectionismade theinsulationstrips should be installed between the insert face plates and the fireplace face The faceplate top may now be installed with insulation stripbehind byaligningitsbracketswiththe top flange on the side shields and the angle iron bar on the insert top The faceplate trim may be insta...

Страница 12: ... or at least 30 minutes after starting fire Your fan should only be installed once the unit is in place in order to prevent any damage to the fan To attach follow the instructions provided with the fan 1 Align the fan support with the offset clip on the bottom of the ashlip 2 Slidethesupportsintotheclips Thetension holdingtheclipsinplacemaybeadjustedby increasing or decreasing the offset spacing o...

Страница 13: ...the air tube into the holes in the side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side as far as possible and then bring it back into the hole on the right hand side Use a pair of vise grips or pliers and tap it into place with a hammer A tighter fit will FLUE BAFFLE SECONDARYAIR TUBE INSTALLATION The flue baffle syst...

Страница 14: ... 3 Do not burn large quantities of paper in your insert 4 Ifyouhavesmokedetectors preventsmoke spillage as this may set off a false alarm 5 Donotoverfireyourinsert Iftheinsertbegin to glow you are overfiring Stop adding fuel and close the draft control Overfiring can cause extensive damage to your stove including warpage and premature steel cor rosion Overfiring will void your warranty 6 Do not pe...

Страница 15: ...esonthefluelining Whenignited this creosote can make an extremely hot fire FAN OPERATION The fan is to be operated only with the draft control rod pulled out at least 1 2 from the fully closed position The fan is not to be oper ated when the draft control rod is in the closed position pushed in The fully closed position is the low burn setting The fan unit must not be turned on until a fire has be...

Страница 16: ...hen it is cool Your local retailer can supply you with special glass cleaner if plain water and a soft cloth does not remove all deposits GLASS REPLACEMENT Your Regency Insert is supplied with 5 mm Neoceram ceramic glass Part 846 304 that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regency...

Страница 17: ...3 Regency Logo Nickel 948 216 Regency Logo Gold 48 820 482 Stainless smoke deflector 918 993 Manual Not available as a replacement part Part Description 1 850 152 Door Assy Large Gold 850 151 Door Assy Large Black 850 153 Door Assy Large Nickel Accent 850 154 Door Assy Large Gold Accent 2 846 304 Glass Replacement 4 936 243 7 8 Adhesive Tape Gasket 5 846 920 Glass Retainer Clips 8 set 6 Screw 1 4 ...

Страница 18: ...lar 287 Trim Left Regular 288 Faceplate Side Regular 289 Faceplate Top Regular 140 913 Faceplate Trim Set Oversize 180 572 Black Trim Oversize set of 3 295 Trim Right Oversize 296 Trim Top Oversize 297 Trim Left Oversize 298 Faceplate Side Oversize 299 Faceplate Top Oversize Not available as a replacement part 285 286 287 288 288 289 REGULAR 296 295 297 298 299 298 OVERSIZE ...

Страница 19: ... I2403M 19 PARTS LIST BRICK PANELS I2403M Part Description 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Partial 1 1 4 x 2 x 9 ...

Страница 20: ...rorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre approved and assigned agent provided that the defective p...

Страница 21: ...ype operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados eart...

Страница 22: ...al or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your add...

Страница 23: ...r us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANAD...

Страница 24: ......

Страница 25: ...Regency I2403M 25 NOTES ...

Страница 26: ...26 Regency I2403M NOTES ...

Страница 27: ......

Страница 28: ..._______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency and Classic are trademarks of FPI Fireplace Products International Ltd Copyright 2018 FPI Fireplace Products International Ltd...

Отзывы: