To Wire Fan Motor
10. Connect one of the black wires from the power cord to the black wire
included with the fan (light blue connector). Connect the other end to
one spade on the thermodisc
11. Connect the red wire to the other open spade on the thermodisc. Connect
the other end to the black wire from the fan motor.
12. Connect the white wire from the fan motor to the black wire on the power
cord (dark blue connector).
13. Slide the thermodisc on to the bracket clip on the bottom of the unit.
Ensure no wires will touch the hot surfaces.
9.
Secure the fan to the base with 2 screws. Note the right access panel
was removed to allow easier access to the right side screw.
14.. Secure the ground wire from the fan assembly and the power cord to
the ground lug located on the back left near the fan.
15. The fan control module (supplied with the fan kit) secures to the side
access panel. Remove 2 top screws and loosen 2 bottom screws to
remove the side access pane
17. Plug in the fan power cord to the Fan Control Module into the outlet
marked “Fan”. Plug the FCM-COM wire from the remote control wiring
harness into the location on the Fan Control Module marked “COM”.
Turn the switch on the Fan Control Module to the ON position. ON is to
the left. The “O” is the off position
16. Install the fan control module (FCM) into the bracket on the side access
panel. Plug in the power cord to the outlet in the unit.