background image

 

H2103 / I3103L

  |    

21

warranty

All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof 

of purchase by you). All claims must be complete and provide full details as requested by FPI to receive 

consideration for evaluation.  Incomplete claims may be rejected. 

 

Replacement units are limited to one per warranty term.  Airtube and baffle replacements are limited to one 

replacement per term. 

 

Unit must be installed according to all manufacturers’ instructions as per the manual. 

 

All Local and National required codes must be met. 

 

The installer is responsible to ensure the unit is operating as designed at the time of installation. 

 

The original purchaser is responsible for annual maintenance of the unit, as outlined in the owner’s manual.  As 

outlined below, the warranty may be voided due to problems caused by lack of maintenance.  

 

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit 

will carry a 90 day warranty, valid with a receipt only. Any item shown to be defective will be repaired or replaced 

at our discretion. No labor coverage is included with these parts 

 

Exclusions: 

This Limited Lifetime Warranty does not extend to paint, rust or corrosion of any kind due to a lack of maintenance 

or improper venting, combustion air provision, corrosive chemicals (i.e. chlorine, salt, air, etc.), firebrick (rear, sides 

or bottom), door or glass gasketing, or any other additional factory fitted gasketing. 

 

Malfunction, damage or performance based issues as a result of environmental conditions, location, chemical 

damages, downdrafts, installation error, installation by an unqualified installer, incorrect chimney components 

(including but not limited to cap size or type), operator error, abuse, misuse, use of improper fuels (such as 

unseasoned cordwood, mill-ends, construction lumber or debris, off-cuts, treated or painted lumber, metal or foil, 

plastics, garbage, solvents, cardboard, coal or coal products, oil based products, waxed cartons, compressed pre-

manufactured logs), lack of regular maintenance and upkeep, acts of God, weather related problems from 

hurricanes, tornados, earthquakes, floods, lightning strikes/bolts or acts of terrorism or war, which result in 

malfunction of the appliance are not covered under the terms of this Limited Lifetime Warranty.  

 

FPI has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications 

or upgrades will not be performed on existing appliances). 

 

This warranty does not cover dealer travel costs for diagnostic or service work.   All labor rates paid to authorized 

dealers are subsidized, pre-determined rates. Dealers may charge homeowner for travel and additional time 

beyond their subsidy. 

 

Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may 

void this warranty. This includes units with rusted or corroded fireboxes which have not been reported as rusted or 

corroded within three (3) months of installation/purchase. 

 

Units which show evidence of being operated while damaged, or with problems known to the purchaser and 

causing further damages will void this warranty. 

 

Units where the serial no. has been altered, deleted, removed or made illegible will void this warranty. 

 

Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this 

warranty. 

 

Freight damages for products or parts are not covered under the terms of the warranty. 

 

Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior 

authorization from FPI may void this warranty. 

 

 

Revision Date: December 2016 

Regency Wood Products Warranty 

 

Содержание H2103

Страница 1: ...046d MODELS H2103 I3103L WOOD Fireplace Insert Hearth Heater 01 30 18 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ...er has been shown to deliver heat at rates ranging from 11 900 BTU hr to 42 900 BTU hr This unit has been tested using 5G series and generates the best efficiency when operated using well seasoned wood and installed in the main living areas where the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inco...

Страница 3: ...install 10 Fan Blower 11 Floor Protection 12 Firebrick Assembly 12 Door Handle 12 Brick Flue Baffle Secondary Air Tube Installation 12 Draft Control 13 Screen Door 13 OPERATING INSTRUCTIONS First Fire 13 Fan Operation All Units 13 Ash Disposal 13 Some Safety Guidelines 13 Creosote 14 MAINTENANCE Maintenance of Gold Plated Doors 15 Door Gasket 15 Door Latch Adjustment 15 Glass Cleaning 15 Glass Rep...

Страница 4: ...1 1 12 A A 27 1 2 699mm 26 660mm 15 13 16 402mm 10 3 8 263mm 1 7 16 36mm 6 7 8 175mm 44 1118mm 32 813mm 4 15 16 125mm 9 7 16 240mm 6 1 4 159mm 22 7 8 581mm 5 1 2 140mm 6 152mm Collar 952mm 37 1 2 23 1 4 590mm Regular Faceplate Oversize Faceplate is 50 W x 34 1 2 H UNIT DIMENSIONS FOR H2103M CHK PROCESS DWN BLANK SIZE PART MAT L ANGULAR INSIDE BEND RADII DIMENSIONS TOLERANCES UNLESS OTHERWISE STATE...

Страница 5: ...L AUG SEPT OCT NOV DEC 106 Serial No No de série Part 908 389c Size 10 06 W x 3 27 H file at 100 Colour Black on grey except for what is highlighted in yellow is red Nov 25 14 Updated ETL Logo Jan 22 14 Updated yrs of manufacture Apr 4 11 updated yrs of manufacture added 5 5 stainless liner Mar 15 10 updated yrs of manufacture Jan 2 08 updated yrs of manufacture 103 DO NOT REMOVE BRICKS OR MORTAR ...

Страница 6: ...rdance with manufacturer s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safety codes before installation of un...

Страница 7: ... Detailedinstallationinstructionsare included with the kit Position the grill on the inside bodyface side and fasten using the bolts washers and nuts provided 2 per side as shown in the diagrams Note Thegrillhasafrontandrear theholes onthefrontsidehaveroundededges and the rear holes have flat edges OPTIONAL FLUE Thermal floor protection is not required if the unit is raised 3 5 minimum measured fr...

Страница 8: ...one of the connection methods listed onthispagenotonlyincreasesthesafetyofyour insert by directing the hot gases up the flue but will also help increase the unit s efficiency and decrease creosote deposits in the chimney When a connected flue or liner is in use the insert is able to breathe better by allowing a greaterdrafttobecreated Thegreaterdraftcan decrease problems such as difficult start up...

Страница 9: ...ection is made the insulation strips shouldbeinstalledbetweentheinsertfaceplates and the fireplace face The faceplate top may now be installed with insulation strip behind by aligning its brackets with the top flange on the side shields and the angle iron bar on the insert top The faceplate trim may be installed to the edge of the faceplate at this time dirty glass 2 In order to position the flue ...

Страница 10: ...tightened bolts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smoke deflect...

Страница 11: ...sition Now that your insert is installed check once more that all the clearances from the unit to any combustible materials are correct as listed earlier FAN BLOWER Your fan should only be installed once the unit is in place in order to prevent any damage to the CAUTION Label all wires prior to disconnection when servic ing controls Wiring errors can cause improper and dangerous operation WARNING ...

Страница 12: ...n slide the2ndBaffleBrickupandback Reposition both baffle bricks flat on the air tubes 3 Important push both baffle bricks so they are tight against the side walls 4 Install the third air tube into the holes on the side channels The notch goes on the right hand side with the air holes facing forward toward the door opening If the tube will not slide in easily simply use a pair of vise grips or pli...

Страница 13: ...front of the locating tabs Make sure that the insulation is lying flat and does not obstruct the smoke from getting up the flue opening Place hold down weights on top of the insulation one on each side DRAFT CONTROL Before establishing your first fire it is important that your fully understand the operation of you draft control The draft rod is on the left side of the Inserts and it controls the i...

Страница 14: ... three seasoned logs to your fire Form a trench in the ash bed to allow air to reach the rear of the firebox prior to closing the door 4 After about 15 to 20 minutes when your wood has begun to burn strongly adjust your draft control down to keep the fire at a moderate level WARNING Never build a roaring fire in a cold stove Always warm your stove up slowly 5 Once a bed of coals has been establish...

Страница 15: ... for re installation In most cases removal and replacement of the baffle system should allow full access for cleaning WARNING Thingstorememberincase of chimney fire 1 Close draft control 2 Call the Fire Department Ways to Prevent and Keep Unit Free of Creosote 1 Burn insert with draft control wide open for about15minuteseverymorningduringburn ing season This helps to prevent creosote deposits with...

Страница 16: ...Gold 948 135 Spring Handle Large Nickel 20 948 132 Spring Handle Small Gold 948 136 Spring Handle Small Nickel 23 820 235 Flue Brackets Pkg 163 915 I3103L Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 063 954 Air Tube 1 I3103 Qty...

Страница 17: ...385 Trim Right Regular 386 Trim Top Regular 387 Trim Left Regular 388 Faceplate Side Regular 389 Faceplate Top Regular 163 912 Faceplate Trim Set Oversize 163 572 Black Trim Oversize Set of 3 395 Trim Right Oversize 396 Trim Top Oversize 397 Trim Left Oversize 398 Faceplate Side Oversize 399 Faceplate Top Oversize Not available as a replacement part ...

Страница 18: ...lts 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 120 954 Air Tube Front 36 120 953 Air Tube Rear 37 836 212 Baffle Insulation 38 Insulation Weights 39 120 950 Steel Baffle 948 216 Regency Logo Faceplate H2103M 120 910 Faceplate Trim Set Regular 120 570 Black Trim Regular set of...

Страница 19: ...k Regular Full Size 1 1 4 x 4 1 2 x 9 71 Brick Partial 1 1 4 x 4 x 9 72 Brick Partial 1 1 4 x 1 3 4 x 9 75 Brick Partial 1 1 4 x 4 x 8 3 4 76 Brick Partial 1 1 4 x 2 x 9 78 Brick Partial 1 1 4 x 2 1 4 x 2 1 4 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not available as a replacement part ...

Страница 20: ...orated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre approved and assigned agent provided that the defective pa...

Страница 21: ...pe operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earth...

Страница 22: ...additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email and telephone contac...

Страница 23: ... us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANADA...

Страница 24: ......

Страница 25: ...H2103 I3103L 25 notes ...

Страница 26: ...26 H2103 I3103L notes ...

Страница 27: ......

Страница 28: ..._______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency and Classic are trademarks of FPI Fireplace Products International Ltd Copyright 2018 FPI Fireplace Products International Ltd...

Отзывы: