background image

920-420

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

02.23.22

C

Grandview

® 

G600C-1  

Gas Fireplace

Owners & 

Installation Manual

www.regency-fire.com

MODELS: G600C-1
Medium DV Gas Fireplace

 

    Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 

    WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

  •  Do not touch any electrical switch: do not use any phone in your building.
    Leave the building immediately.
  •  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.
  • If you cannot reach your gas supplier, call the fire department.
   

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Installer: 

 

Please complete the details on the back cover and leave 
this manual with the homeowner.

Homeowner

:

 

Please keep these instructions for future reference.

Certified to/Certifié pour:
ANSI Z21.88:19
CSA 2.33:19
CSA 2.17-2017
                                        

Tested by: 

     Warning
Fire or Explosion Hazard
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

Содержание Grandview G600C-1

Страница 1: ...ng Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Installer Please complete the details on the back cover and leave this manual with the homeowner Home...

Страница 2: ...ent Label 4 34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equally conspicuous position where the instruction can be easily read April 22 14 Created draft Double sided Material Synthetic Paper Size 5 965 W x 5 71 H Color As shown in artwork DANGER HOT GLASS WILL CAUSE BURNS DO NOT TO...

Страница 3: ... current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes The appliance when installed must be electrically grounded in accordance with local ...

Страница 4: ...d other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 6 Follow the lighting instructions Place the appliance being inspected into operation Adjust the thermostat so appliance is...

Страница 5: ...ng Arrangements Horizontal Termination Rigid Pipe and Direct Vent System Flex 52 Venting Arrangements Vertical Termination Rigid Pipe System and Vertical Flex Kit to Same Limitations 53 Horizontal Terminations Two 90 Elbows 54 Horizontal Terminations Three 90o Elbows 54 Vertical Venting With Two 90o Elbows 55 Vertical Venting With Three 90o Elbows 55 Venting Arrangements with Co linear Flex System...

Страница 6: ...EC L APPAREIL For Use Only with Barrier Part 776 109 P Utiliser uniquement avec l écran n 776 109 P DO NOT REMOVE THIS LABEL NE PAS ENLEVER CETTE ÉTIQUETTE 562 562 DOOR SEAL Please check that the door is properly sealed FPI Fireplace Products International Ltd Delta BC Canada Minimum Clearances to Combustibles Rear Vent Clean Finish Dégagements minimaux par rapport aux matériaux combustibles Seria...

Страница 7: ...ctly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspect...

Страница 8: ...T GAS INLET ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS 37 3 4 959mm 34 3 4 883mm 37 1 2 953mm 34 5 8 880mm Finishing Trim Faceplate 30 7 8 784 mm 33 3 4 857 mm 33 1 2 851 mm 30 5 8 778 mm 21 3 4 552 mm 26 1 8 664 mm 25 635mm Note Gas connection is from the left hand side of the appliance electrical conne...

Страница 9: ...erted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply with venting diagrams Is venting installed and secured and are clearances for the vent pipe and termination cap maintained If applicable was a 1 4 rise maintained for every foot of horizontal run Was the termi...

Страница 10: ...r shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed and flame modulation checked Customer Tutorial and Presentation YES NO Is the customer confident operating the new gas appliance and aware of all the features on the remote Confirm that the rating and ligh...

Страница 11: ...DIVIDUALSOUT OF THE ROOM AND AWAY FROM HOT SURFACES ANY SAFETY SCREEN GUARD OR BARRIER REMOVED FOR SERVICING THE APPLIANCE MUST BE REPLACED PRIORTOOPERATINGTHEAPPLIANCE IFTHE BARRIER BECOMES DAMAGED THE BARRIER SHALL BE REPLACED WITHTHEMANUFACTURER SBARRIER FOR THIS APPLIANCE A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS FROM THE HOT VIEWING GLASS IS PROVIDED WITH THIS APPLIANCE AND SHALL BE INST...

Страница 12: ...the appliance 8 To prevent injury do not allow anyone who is unfamiliarwiththeoperationtousethefireplace 9 Wear gloves and safety glasses for protection while doing required maintenance 10 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 11 Under no circumstances should this appliance be modified Parts that have to be removed for servicing should be ...

Страница 13: ...low Cradle Extender Knob 2 Slide the knob extender over the pilot on off knob located on the gas valve See below 3 Follow instructions on how to light the pilot in this manual or the lighting plate located on the underside of the unit 4 Once the pilot is lit remove the knob extender and put it back into the cradle for future use On off pilot knob on gas valve Knob extender slid over on off pilot k...

Страница 14: ...ur de l appareil pour déceler une odeur de gaz Reniflez au niveau du plancher car certains gaz sont plus lourds que l air et peuvent s accumuler au niveau du sol QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne tentez pas d allumer l appareil Ne touchez à aucun interrupteur n utilisez pas de téléphones se trouvant dans le bâtiment Sortez du bâtiment immediatement Appelez immédiatement votre fournisseu...

Страница 15: ... position A single acoustic signal from the receiver confirms the reception of the command Low Battery Detection Transmitter Thedurationoftheremotecontrolbatteriesdepends on many factors the quality of the batteries used the number of ignitions of the appliance etc If the transmitter batteries are low the light intensity of the LED see Fig 5 will decrease when you press the ON OFF key to alert you...

Страница 16: ...nstallation Glass Door Removal 1 To install the door Reverse steps above 1 To remove the glass door place both hands on either side of the latch Pull forward then up to unlock repeat on opposite side Important After releasing the latches support the weight of the door 2 With both latches released support the door with both hands and tilt out to approximately a 60 degree angle 3 Lift the door up an...

Страница 17: ...framed opening 3 Install vent Refer to Venting sections 4 Make gas connections Test the pilot Must be as per Diagram Refer to Pilot Adjustment section Convert to propane if desired Refer to Gas Line Installation and Conversion Kit from NG to LPG sections 5 Make electrical connections to receptacle sup plied with unit recommended 6 Install standard and optional features Refer to the following secti...

Страница 18: ...ling Flange Installation 20 Nailing Flange Installation 21 Cool Wall Clearances 23 Cool Wall Mantel Clearances 24 Cool Wall Mantel Leg Clearances 24 Cool Wall Installation Framing 25 Cool Wall Installation Cool Wall Conversion 26 Chase Venting 27 Chase Enclosure Cool Wall 28 Chase Vent Installation Cool Wall Part 776 941 29 Clean Front Installation Non Cool Wall Clearances 30 Clean Front Installat...

Страница 19: ...ible Installation Clean Front Standard Install Non vented chase Non combustible board required Combustible framing Cool Wall Install Vented chase Combustible material can be used all around the fireplace Combustible framing Clean Front Clean Front Outside Finish w Finishing Trim Outside Finish w Faceplate ...

Страница 20: ...used including the backing mate rial The depth of finishing material can be adjusted in 1 4 increments 1 If venting the unit in a top vent configuration first intall the top vent heat shield with two screws as shown 2 Determine the required depth setting for the materials being used 3 Once the setting has been chosen install the Left and Right Nailing Flanges with 2 screws on each Flange Nailing F...

Страница 21: ...It _ Finishing Material Depth Flush 11 4 3 4 1 4 Setting Front of Fireplace I I 0 I 0 0 0 0 0 0 0 0 Top Nailing Flange Nailing Flange Installation 4 Screw one screw into the rear hole on each Side Nailing Flange 5 Install the Top Nailing Flange with 4 screws ...

Страница 22: ...l Drywall etc Distance to combustible material varies with install OUTSIDE FINISH Finishing Material Backing Material Drywall etc Flush Finishing Material CLEAN FRONT Header Deflector 1 1 4 32 mm Max 6 Slot the Header Deflector onto the back screws then secure the with a screw through the remaining front hole on each flange ...

Страница 23: ... min 1 25mm Top of Fireplace Opening B Sidewall 6 152mm Side of Fireplace Opening C Ceiling 44 1 4 1124mm Top of Fireplace Opening D Mantel Depth max 12 305mm Front of Fireplace Opening E Alcove Width 84 2134mm Wall to Wall Minimum F Alcove Depth 36 914mm Front to Back Wall Maximum G Convection Air Outlet 58 in2 375cm2 Top Front of Enclosure H Convection Air Outlet Opening Offset 0 2 0 51mm Top of...

Страница 24: ...235mm 5 1 2 140mm 1 25mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12 305 mm 1 51 mm 7 178 mm A B 14 To Floor 5 10 Inches C D Mantel leg Allowable mantel leg projection TopView Side opening of fireplace Mantel leg Mantel leg 2 51 mm 3 76 mm 1 3 4 44 mm 28 3 4 729 mm overall fireplace width see note above Clean Finish 5 127 mm 6 152 mm Cool Wall Mantel Leg Clearances Se...

Страница 25: ... 3 1 2 89mm W Clearance to Corner of Unit 1 2 13mm Important Framing height requires consideration of the hearth height Dimension N N the thickness of the installed hearth P R M N O S S U T V Combustible header Top Vent Rear Vent W Q Note The 2 standoffs at the rear of the appliance may be removed as these are not required in this application Ensure that any screws that are removed are reinstalled...

Страница 26: ... side of the unit with one screw as shown 7 Loosen the two outermost screws which are accessed through the holes in the locations show below NOTE Do not remove these two screws loosen them 8 Reach underneath the top of the unit and locate the lower sliding portion of the cool wall assembly Push this piece toward the back of the unit as far as it will go to open the cool wall air channel 4 Remove t...

Страница 27: ...emperatures This can be achieved in a number of ways including the examples shown below Warning DO NOT cover or place objects in front of the air outlets CHASE VENTING A minimum 58 in2 opening in the enclosure is required to maintain safe operating temperatures This can be achieved in a number of ways including the examples shown below Warning DO NOT cover or place objects in front of the air outl...

Страница 28: ...tc to prevent heat from escaping anywhere above through the enclosure other than the required grill ventilation opening Internal chase When installing as an internal chase framing installation regardless of where appliance is placed within the home requires the use of either drywall or other means such as plywood on the rear wall of the chase to eliminate heat escaping into the rear wall cavity If...

Страница 29: ...hase vent The top of the chase vent opening must be 2 51 mm or less from the top of the chase enclosure Fasten the chase vent with screws and construction adhesive If the chase vent is not being used a minimum 58 in2 374 cm2 opening in the enclosure is required to maintain safe operating temperatures This can be achieved in a number of ways including a reveal at the top of the chase 08 11 20 920 1...

Страница 30: ...in required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles Clearance Requirements Clearance Dimension Measured From A Mantel Height min 14 356mm Top of Fireplace Opening B Sidewall 25 635mm Side of Fireplace Opening C Ceiling 36 914mm T...

Страница 31: ...acing are shown in the Diagram on the right Note Ensure the paint that is used on the mantel and the facing is High Quality or the paint may discolour Mantel Clearances A B C D From Top of Fireplace Opening 28 3 8 721mm 23 584mm 19 1 4 489mm 14 356mm Combustible Mantel Clearances 0 5 10 0 Top of Fireplace Opening 12 305 mm 5 127 mm 17 432 mm A B 15 To Floor Inches C D Non Combustible Material Min ...

Страница 32: ...INISHING MATERIAL IN THIS AREA No Combustible Materials in this Area 33 1 2 851mm 13 331 mm 3 76mm 3 76mm 26 3 4 679 mm 1 5 8 41 mm 3 76mm See framing dimensions on next page Allowable mantel leg projection TopView Side opening of fireplace Mantel Mantel leg 38mm 4 1 4 108mm Leg 3 76mm 6 7 8 175mm 32 1 2 826mm Overall Fireplace width 1 1 2 2 38mm 51mm 28 3 4 729 mm Overall Fireplace Width Clean Fin...

Страница 33: ...nnection Height 1 7 8 48mm U Gas Connection Inset 8 3 8 213mm V Gas Connection Width 3 1 2 89mm W Clearance to Corner of Unit 2 51mm Non combustible Facing Height 13 330mm Important Framing height requires consideration of the hearth height Dimension N N the thickness of the installed hearth S S U T V Q P M N O Combustible header R Top Vent Rear Vent W S1 See previous page for details on non combu...

Страница 34: ...ling flanges see manual for instructions 2 Loosen the four 4 screws that secure the left and right nailing flanges to the unit 3 Slidetheleftandrighttilingflangesonto the front of the fireplace Use the slots to center with the screw securing the nailing flanges Diagram 1 4 Tighten screws 5 Slide the bottom tiling flange against thebottomofthefireplace Securewith a screw on each side 6 Finishing ma...

Страница 35: ...quired clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles Outside Finish Clearance Requirements Clearance Dimension Measured From A Mantel Height min 12 305mm Top of Fireplace Opening B Sidewall 25 635mm Side of Fireplace Opening C Ceiling ...

Страница 36: ...earances A B C D From Top of Fireplace 30 762mm 19 1 2 495mm 15 3 4 400mm 10 1 2 267mm Combustible Mantel Clearances 0 5 10 0 Top of Fireplace 12 305 mm 5 127 mm 17 432 mm A B 15 To Floor Inches C D Non Combustible Material Min 10 1 2 H 267mm 5 10 20 15 Outside Finish Installation Non Cool Wall Mantel Leg Clearances Allowable mantel leg projection TopView Side opening of fireplace Mantel Mantel Leg...

Страница 37: ... Height 1 7 8 48mm U Gas Connection Inset 8 3 8 213mm V Gas Connection Width 3 1 2 89mm W Clearance to Corner of Unit 2 51mm Non combustible Height 10 1 2 267mm Important Framing height requires consideration of the hearth height Dimension N N the thickness of the installed hearth S S U T V Q P M N O Combustible header R Top Vent Rear Vent W Corner Top Vent Only IMPORTANT Corner applications are v...

Страница 38: ...38 Grandview G600C 1 Gas Fireplace installation Outside Finish Finishing Finishing material may be brought to the top and side edges of the fireplace as shown below 30 32 ...

Страница 39: ...sh past the front face of the fireplace 3 4 19 mm Nailing Flange Tabs folded forward Mounting Tabs folded forward Mounting Tab Folded Forward Nailing Flange folded forward Framing Face Plate Install the faceplate by resting the arms on the Face Plate on top of the mounting tabs Adjust left and right to center the Face Plate NOTE Do not touch the faceplate without clean soft gloves Dirt or oils can...

Страница 40: ...ght 5 Fold the tab down to secure Right Side Finishing Trim Install Instructions 1 Bend the four tabs on the outer box front forward There are two tabs per side These tabs are the mounts for the faceplate or finishing trim 2 Bend the two tabs on the top nailing flange down 3 Bend the tabs on the left and right nailing flanges forward There are two tabs per nailing flange Top and Side Nailing Flang...

Страница 41: ...m Top View Mounting Tab Folded forward Nailing Flange folded forward Install the faceplate by resting the arms on the finishing trim on the top of the mounting tabs Adjust left and right to center the finishing trim Critical Finishing Gap Side View A 1 2 13 mm gap must be maintained on the sides and top of the fireplace to allow the finishing trim to be installed and removed The finishing trim has...

Страница 42: ...learances are maintained WARNING Risk of Fire Maintain specified air space clearances to combustibles Inadequate air space could cause overheating and fire The appliance is designed to be used with 1 2 in 13 mm wall sheathing materials such as drywall plywood wood composites or non combustible materials Thicker materials may be used Refer to facing and finishing details in this manual Facing Mater...

Страница 43: ...rim piece 2 Remove the intake over plate from the rear by removing the top 2 screws and loosening the bottom 2 screws Diagram 1 Diagram 6 Diagram 9 Diagram 2 Diagram 3 3 Remove the exhaust cover plate from the rear by removing the top 4 screws and loosening the bottom 2 screws Hidden screw Diagram 4 4 Remove the intake collar from the top by removing 4 screws Diagram 5 Hidden screw Hidden screw 5 ...

Страница 44: ...inserting into the area on top of the exhaust cover plate Position it forward so that the insulation is held in place by the bend on the exhaust cover plate 8 Install the intake cover plate on top using the same screws that previously held the intake collar Diagram 12 9 Install the second piece of supplied insulation by inserting into the area on top of the intake cover plate Diagram 14 Diagram 15...

Страница 45: ...ecure in place with the 4 top screws and then tighten the 2 bottom screws Diagram 16 11 Install the intake collar onto the rear Hang the collar onto the previously loosened bottom screws secure in place with the 2 top screws and then tighten the 2 bottom screws Diagram 18 12 Reinstall the collar trim piece with 6 screws Diagram 19 Diagram 17 Hidden screw ...

Страница 46: ...e must use it s own separate vent system Common vent systems are prohibited Vent Restrictor Installation Part 776 027 Diagram 2 Vent restrictor located on top exhaust assembly 1 Determine the venting configuration 2 Go to venting arrangements section in the manual to determine if a vent restrictor setting is required If required proceed to Step 3 3 Loosen the two screws that secure the top heat de...

Страница 47: ...each side of center line extended above meter regulator assembly J Clearance to service regulator vent outlet K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public prope...

Страница 48: ...A N A 4DAL N A TC 4DLT N A Adjustable Length 3 10 Black N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLS...

Страница 49: ...05 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 946 523 P AstroCap Horizontal Cap 946 206 Vinyl Siding Standoff for AstroCap The rigid pipe adaptor is not required on the C34 C34E U39 U39E H15 H27 H35 RC500E Note When using Metal Fab Sure Seal Rigid Piping pl...

Страница 50: ...of 3ft 0 9m Note Must use optional rigid pipe adaptor Part 510 994 when using Rigid Pipe vent systems Maintain clearance to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall 2 0 12 6 4 8 10 2 0 6 4 8 Vertical Height Feet Rigid 39 1 2 1 1 m Horizontal Feet Max 36 0 9 m Flex 39 1 2 1 1 m Set 2 Set 1 24 0 61 m 25...

Страница 51: ...irect Vent Ameri can Metal Products Olympia Ventis DV Security Secure Vent AmeriVent Direct Vent AstroCapTM is the proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with DuraVent Direct Vent Selk...

Страница 52: ... elbows equal one 90o elbow Note Must use optional rigid pipe adaptor Part 510 994 when using Rigid Pipe venting systems Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Note FPI Direct Vent Flex System Part 946 513 2 footor0 61m 946 515 4 foot or 1 22 m and 946 516 10 foot or 3 05 m on...

Страница 53: ... combinations of straight vertical and offset to vertical terminations using two 90o elbows with rigid pipe vent systems for Propane and Natural Gas 6 6 9 9 1 12 2 Vertical Height Feet Horizontal Feet 7 7 9 9 1 11 1 1 13 3 1 15 5 1 17 7 1 19 9 2 21 1 2 23 3 2 25 5 2 27 7 2 29 9 3 31 1 3 33 3 0 0 1 1 3 3 5 5 Set 3 1 1 2 open 0 0 Set 4 1 1 4 open Set 1 2 open 8 V Min 3 35 5 3 3 3 37 7 39 1 2 1 1 m M...

Страница 54: ...gid venting Horizontal Terminations Three 90o Elbows One 90o elbow Two 45o elbows Option V H V V1 H H1 With these op tions max total pipe length is 30 feet with min of 12 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90o elbows is required A 0 Min 1 0 3 m Max 1 0 3 m Min 2 0 61 m Max B 1 0 3 m Min 2 0 61 m Max 3 0 91 m Min 3 0 91 m Max C 2 0 61 m Min 2 0 61 m M...

Страница 55: ... 43 m Max 7 2 13 m Min Restrictor Set 1 2 51 mm open Lengths do not include elbow indicated Required when using rigid venting One 90o elbow Two 45o elbows Option V H H1 V V1 W i t h t h e s e o p t i o n s maximum total p i p e l e n g t h is 30 feet with minimum of 10 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is re quired A 0 Min 2 0 61 ...

Страница 56: ...on 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adapter Alternate Approved Caps 46dva VC Vertical Termination Cap 46dva VCH High Wind Cap 46dva GK 3 Co linear Adapter with flashing Flex Liner Exhaust Flue A maximum of two certified joiner ...

Страница 57: ...16 mm 30 Horizontal Distance Feet Vertical Height feet 8 2 44 m Min 39 1 2 1003 mm 30 9 14 m Max 30 Horizontal Distance Feet Vertical Height feet 2 0 61 m max Combined min of 8 2 44 m 6 1 82 m max 39 1 2 1003 mm Combined max of 30 9 14 m 30 Horizontal Distance Feet Vertical Height feet 2 0 61 m max IMPORTANT As shown below the unit can only be vented from the top not from the rear Restrictor at Se...

Страница 58: ...t Follow the same installa tion procedures as used for standard Horizontal Termination NEVER install the snorkel upside down Below Grade Installation IftheSnorkelTerminationmustbeinstalledbelow grade i e basementapplication properdrainage must be provided to prevent water from enteringtheSnorkel Termination Refer to Diagram 4 Do not attempt to en close the Snorkel within the wall or any other type...

Страница 59: ...otheposition oftheapplianceflueexit and mark the location where the vent will penetrate the ceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previouslydrilledintheceiling andmark the spot where the vent will penetrate the roof Determine if ceiling joists roof rafters or other framing willobstructthe ventingsystem You may wish to relocate the appliance or to o...

Страница 60: ... e n d framing out a square to mount the terminal to Outside Wall Mur extérieur Furring Strips Fourrures en bois Furstrp eps see also c34020a eps furstrpf eps french Offset Chart Direct Vent System Flex Installation Procedures 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the cente...

Страница 61: ...pe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length until it reaches the flashing 16 Install termination cap by twist locking it...

Страница 62: ...m 1 Diagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop CEILING FIRESTOP FIRESTOP SPACER PART 946 757 Used in conjunction with the 946 755 Vertical Flex Kit ...

Страница 63: ...pilot retainer clip 11 Remove burner orifice with a 3 8 wrench Use another wrench to hold the elbow behind the orifice Discard orifice 12 Reinstall new LPG burner orifice stamped 55 and tighten 7 Remove the pilot retainer clip below the pilot cap 9 Unscrew the pilot orifice with the Allen key Replace it with the LPG pilot orifice provided in the kit Pilot retainer clip 8 Pull off the pilot cap to ...

Страница 64: ...screw is clean and remove dirt if necessary 17 Flip the screw Fig 3 18 Using the Allen wrench as shown in Fig 4 rotate the screw clockwise until snug Do not overtighten WARNING Do not over tighten the screw Recommended to grip the wrench by the short side 22 Attach the label This unit has been converted to LPG near or on top of the serial decal 23 Replace yellow NG label with red LPG label 24 Rein...

Страница 65: ...the firebed grate media vermiculite embers and logs until the brick panels are installed Brick panels will discolor a little during normal operation This is normal and should not be considered a defect 3 Loosen 2 screws on pilot assembly in locations shown below Slide pilot shield towards the back of the unit and remove from unit 8 Repeat Steps 5 7 on the left side 9 Slide the bottom panel careful...

Страница 66: ... be considered a defect All hand and fingerprints MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to remove any fingerprints before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty G600EC G600C 3 Loosen 2 screws on pilot assembly in locations shown below Slide p...

Страница 67: ...Broken logs can interfere with the pilot operation TheG600EC G600C G600C 1logsets 776 930forGrandviewOak 776 932 for Grandview Birch contain the following pieces NOTE Panels brick steel or enamel must be installed prior to installing the log set 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position when installing 2 Install the lo...

Страница 68: ...tall Log 2 on left log support plate Line up the pins on the plate with the pin hole on the log 7 Install Log 3 on right log support plate Line up the pins on the plate with the pin hole on the log 8 Install Log 4 diagonally across Log 2 Rest Log 4 in the notch out on Log 2 as shown 9 Install Log 5 one end will rest in the notch out on Log 3 the Y end will rest on the 3rd prong from the right on t...

Страница 69: ... 8 at the front of the log grate The cutouts in Log 8 should rest in the 4th 5th prongs from the right of the log grate 13 Install Log 9 to the right of Log 5 The cutout in Log 9 will rest in the 2nd prong from the right on the log grate Diagram 12 Install Log 7 Diagram 13 Install Log 8 Diagram 14 Install Log 9 Diagram 11 Install Log 6 7 1 6 1 8 9 4 5 14 Install Log 10 as shown The flat bottom wil...

Страница 70: ...re flame flows smoothly If there is any flame hesitation check that area for any blockage of the burner ports Diagram 18 Final Installation Diagram 17 Install Log 12 12 7 G600EC G600C 16 Install Log 12 on the firebox floor near Log 7 as shown 1 12 2 3 4 5 6 7 8 9 10 11 Glass crystals must be placed at least 1 away from the front edge of the unit ...

Страница 71: ...installation Grandview G600C 1 Gas Fireplace 71 09 04 20 920 294 LOG SET INSTALLATION Page 5 of 4 Glass crystals must be placed at least 1 away from the front edge of the unit steel panels shown ...

Страница 72: ... across the tray in one even layer Important ensure that at least 50 of the gas burner porting remains uncovered Do not cover the pilot area BURNER PORTING PILOT 4 If using volcanic stones as additional media add a maximum of 10 as shown below Important Volcanic stones should not cover any of the gas burner porting or pilot areas Note The optional brick steel or enamel panels must be installed pri...

Страница 73: ... 5 Place Log 1 against the back of the firebox centered as shown Make sure Log 1 is sitting on the tray 6 Place Log 2 on the lefthand side of the tray as shown Ensure the left pin of Log 1 fits into the hole on the underside of Log 2 Make sure Log 2 is supported by the tray see encircled 7 Place Log 3 in the front right area of the tray as shown 2 Ensure there is no ember media underneath the two ...

Страница 74: ...hthand side of the tray as shown Ensure the right pin on log 1 fits into the hole on the underside of Log 4 Make sure Log 4 is supported by the tray see encircled 9 Place Log 5 in the front left area of the tray as shown Important Ensure no logs cover the gas burner porting area 10 To remove the driftwood media tray reverse the steps 1 9 1 4 5 ...

Страница 75: ...ot over tighten High Elevation The G600C 1 is approved in Canada for altitude to 4500 ft CAN CGA 2 17 M91 For Natural Gas installations above 4500 ft follow current CAN CGA B149 1 SIT Valve Description 1 Gas on off knob 2 Manual high low adjustment 3 Pilot Adjustment 4 Thermocouple Connection option 5 Outlet Pressure Tap 6 Inlet Pressure Tap 7 Pilot Outlet 8 Main Gas Outlet 9 Alternative TC Connec...

Страница 76: ...r warranty Pull lever forward to open push back to close Air shutter lever located in the center of the unit under the firebox Electrical Access and Installation The electrical access panel is on the right side of the unit when facing the front of unit 1 Remove panel by removing three 3 screws 2 Remove center knockout to run cable through the access panel and install supplied clamp 3 Attach wires ...

Страница 77: ...nnect the two wires as per wiring diagrams CAUTION Do not wire millivolt remote control wires to 120V wire 2 Install 3 AAA alkaline batteries in the transmit ter and 4 AA alkaline batteries in the receiver and follow the instructions that came with the remote control Optional Wall Switch Not Supplied by Regency 1 Run the supplied 10 of wire through the right or left side gas inlet opening Be caref...

Страница 78: ...an Optional Wall Switch Not Offered by Regency or Thermostat Part 910 407 or 910 404 P 2 Locate the black wire running from the valve to the unit on off switch Unclip the wire holder clip and remove the black wire from the clip 3 Break the connection between the inline wire connectors on the black wire The wall switch or thermostat wiring will run to these two connec tors 4 Route the wiring for yo...

Страница 79: ...k Wire 4 Pilot Assembly 910 038 P NG 910 039 P LP W840470 Pilot Assembly Gasket not shown 5 910 341 Thermopile 6 910 096 Three Way Pilot Hood 7 910 030 Electrode 8 910 386 Thermocouple 9 911 159 120 V AC Power Cord 10 910 692 Green Ground Wire 11 910 412 Rotary Speed Control Item Part Description 12 910 962 Ground Wire 13 911 290 P Fan 14 910 811 Black Wire 15 910 142 Fan Thermodisc normally open ...

Страница 80: ...ons shown below Gently fold panel cover upwards FAN INSTALL AFTER UNIT INSTALLATION Diagram 4 fan wires Diagram 5 DFC wires Diagram 6 ground wires 3 From the back of the unit remove 4 screws from the fan access panel locations shown below 4 Push fan speed control module towards the front of the unit this will later be screwed in place from the front and attach thermo disc cage to bracket on the un...

Страница 81: ...control module with 2 screws see steps 4 5 from previous page Tidy ground wires with provided plastic wire clip 8 Install fan onto pins at the back right of the unit floor Push down on the front of the fan bracket to raise the back of the fan assembly onto the pins 9 Attach thermodisc cage to the bracket on the underside of the fan access panel 10 Reinstall all removed components by reversing step...

Страница 82: ...kit by breaking the connection of the wires at the connectors shown below Dis card the fan speed control module Item Part No Description 1 911 159 Power Cord 2 910 692 Green Ground Wire 3 911 290 P Fan 4 911 240 Brown Connector Cable 5 910 896 Black Wire 6 910 142 Fan Thermodisc 7 910 811 Black Wire Item Part No Description 1 910 367 Junction Box 2 910 412 Speed Contron Switch w Lead Wires 3 910 4...

Страница 83: ...91a G800C 2 3 Reconnect the wires at connectors where the fan speed control module was previously located by using the supplied connector cable as shown 4 Install the fan kit as shown in the unit manual disregarding the steps involving the fan speed control module ...

Страница 84: ...he black wire from the clip 4 Break the connection between the inline wire connectors on the black wire 5 Connect the two connectors on the black wire to the two wires from the remote receiver as shown 6 Put the receiver in position in the holder bracket beneath the firebox to the right of the DC Sparker and Fan Speed Control Module if installed Secure with supplied velcro strips 7 Tidy the wires ...

Страница 85: ...llation Glass Door Removal 1 To install the door Reverse steps above 1 To remove the glass door place both hands on either side of the latch Pull forward then up to unlock repeat on opposite side Important After releasing the latches support the weight of the door 2 With both latches released support the door with both hands and tilt out to approximately a 60 degree angle 3 Lift the door up and ou...

Страница 86: ...n the glass is cold and the appli anceislit itmaycausecondensation andfogtheglass Thiscondensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPTTO CLEANTHE GLASS WHILE IT IS STILL HOT DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE First Fire Normal Operating Sounds of Gas Appliances It is possible that you will hear some sounds from your gas appliance Thi...

Страница 87: ...e the correct polarity 5 Reinstall battery compartment door 1 Remove screen See instructions in this manual on screen removal 2 Locate DC sparker box see diagram 2 located on right hand side of the gas valve 3 Install the supplied AA alkaline battery into the DC sparker box by opening the battery compartment door NOTE The AA battery in the DC sparker box will need to be replaced annually If the AA...

Страница 88: ...er and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brush as the logs are fragile and easily dam aged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner The glass should be cleaned when it starts looking cloudy 3 The...

Страница 89: ...es Diagram 6 Replacing Thermocouple 1 Follow steps 1 13 for replacing valve 2 Disconnect thermocouple at gas valve 3 Disconnect thermocouple at pilot assembly end 4 Replace thermocouple 5 Reverse steps 1 13 6 Remove lower brick or enamel panel 7 Remove 3 screws securing the burner and then slide the burner assembly to the right to release it from the orifice then lift it out 10 Disconnect the two ...

Страница 90: ...s service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of these or other conditions arise d...

Страница 91: ... Grandview G600C 1 Gas Fireplace 91 parts list Main Assembly 19 18 20 17 14 2 16A 29 31 28 27 23 30 32 24 26 22 16 13 15 1 3 4 5 6 7 8 9 10 11 12 25 21 21 ...

Страница 92: ...een Ground N S 396 179 Pilot Assembly Gasket N S 396 178F Pilot Assembly Plate N S 948 099 Spring Compression 3 inch Long Zinc Plated LC 085J 10 M N S 936 157 Gasket Tadpole Tape Sold Per Foot 9 Feet Required Part Description 1 776 774 P Valve Assembly NG 1 776 776 P Valve Assembly LP 2 911 350 Novasit Gas Valve Only NG LP 3 8 11 0 821 844 3 910 038 P Novasit Pilot Assembly NG 4 910 039 P Novasit ...

Страница 93: ...61 047F Plate Light Gasket Clamping N S 761 049 Brick Enamel Panel Clip Each N S 776 027 Restrictor Plate N S 761 107 Gasket Exhaust Cover Plate N S 761 108 Gasket Intake Cover Plate N S 776 130 Board Calcium Silicate 32 W X13 H N S 776 064 Insulation Rear Enamel Painted Panel Optional Accessories N S 776 901 Brick Panel Standard Brown N S 776 903 Brick Panel Herringbone Brown N S 776 904 Brick Pa...

Страница 94: ...Warranty Subsidized Labor Coverage Years Warranty Coverage Parts and Labor 5 years 2 years 1 year Firebox and Heat Exchanger 3 Steel Burner Tube 3 Glass Thermal breakage only 3 All Surrounds Inlays Finishes 3 Brick Panels Log sets Ceramic Burners 3 All Castings 3 Valve assembly and all gas control components Pilot assembly flame sensors Spark Electrode Pilot Tubing Orifices Thermocouple Thermopile...

Страница 95: ...ound to be defective Please refer to the table on first page of this warranty for items covered by the Limited Lifetime Warranty Product changes might be the result of the original Appliance being discontinued changes in regulatory requirements product advancements etc which are beyond the control of FPI This Limited Lifetime Warranty does not cover any installation costs or costs associated with ...

Страница 96: ...THE EXTENT PERMITTED BY APPLICABLE LAW FPI MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED THEN SUCH WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY Some US states do not allow limitations on how long an implied wa...

Страница 97: ...us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANADA ...

Страница 98: ...98 Grandview G600C 1 Gas Fireplace notes ...

Страница 99: ... Grandview G600C 1 Gas Fireplace 99 notes ...

Страница 100: ...________________________________________________________ Phone _ ___________________________________________________________ Date Installed ________________________________________________________ Serial _____________________________________________________________ Printed in Canada Regency and City Series are trademarks of FPI Fireplace Products International Ltd Copyright 2022 FPI Fireplace Prod...

Отзывы: