Regency Gosford Freestanding Wood Fire
7
installation
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
原图号/物料号
比例
共 张 第 张 用于第 张
数量
Shanghai Canature Group FPI(China) LTD.
Ca
n
ature
開能
上海开能壁炉产品有限公司
工艺
标准化
批准
设计
审核
版本号
更改描述
签名
年月日
B
A
E
E
D
G
F
H
F300B
安全间距
1
1
All measurement are in mm
Tolerance±4%
材料
1:1
原图号/物料号
比例
共 张 第 张 用于第 张
数量
Shanghai Canature Group FPI(China) LTD.
Ca
n
ature
開能
上海开能壁炉产品有限公司
工艺
标准化
批准
设计
审核
版本号
更改描述
签名
年月日
C
C
E
E
D
G
F
H
F300B
安全间距
1
1
All measurement are in mm
Tolerance±4%
材料
1:1
Universal
Default Kit
*(1)
Universal
Default Kit
*(2)
Universal
Default Kit
*(3)
AHD Special
Insulated Kit
*(3)
A
390mm
390mm
390mm
420mm
B
280mm
160mm
220mm
220mm
C
200mm
200mm
200mm
200mm
D
280mm
160mm
220mm
220mm
E
123mm
123mm
123mm
123mm
F
380mm
380mm
380mm
380mm
G
1015mm
1015mm
1015mm
1015mm
H
1200mm
1080mm
1140mm
1140mm
Floor Protection
A combustible floor must be protected by non-combustible material (like
tile, concrete board, or as defined by local codes) extending beneath
the heater as follows;
From Sides:123mm
From Front: 380mm
From Back: As per D above.
The floor protector should consist of 12mm thick cement fibre sheet
which has a thermal resistance of 0.8m
2
k/w for 4mm sheets of cement
fibre sheet.
The flue pipe shall extend not less
than 4.6m above the top of the
floor protector.
NOTE: Installation must be carried
out by a licensed installer in
accordance
with AS/NZS 2918:2001.
IMPORTANT
*.(1).The.
Universal Triple Skin Default Kit
.when.fitted.with.either.1.
or.2.lengths.of.130.degree.solid.back.900mm.decromesh..
*.(2).The.
Universal Triple Skin Default Kit
with.2.x.900mm.130.
degree.solid.back.decromesh.and.1.x.450mm.stainless.shield.fitted.
between.active.flue.and.decromesh.
*.(3).The.
Universal Triple Skin Default Kit
with.1.x.130.degree.
stainless.shield.x.900mm.or.1.x.900mm.130.degree.solid.back.
dec.1.x.450.mm.stainless.shield.fitted.between.active.flue.
and.decromesh.
*.(4).The.
AHD Special Insulated Flue Kit
.must.be.installed.with.a.
40mm.air.gap.around.the.flue.to.any.combustible.surfaces.and.the.
ceiling.ring.must.be.spaced.as.such.to.provide.an.air.gap.of.10mm.
to.the.ceiling..
The.AHD.Special.Insulated.flue.kit.must.be.installed.with.a.perfo-
rated.ceiling.plate.with.15.x.11mm.holes.and.a.250mm.diameter.x.
150mm.high.heat.shield.positioned.directly.above.the.ceiling.plate.
NOTE:
.A.minimum.clearance.of.160mm.(flat.wall).or.200mm.(corner.wall).must.be.retained.for.all.wall.surfaces.to.allow.for.fan.access.and.maintenance.
Содержание GOSFORD
Страница 18: ...18 Regency Gosford Freestanding Wood Fire ...
Страница 19: ...Regency Gosford Freestanding Wood Fire 19 ...