maintenance
Fan Replacement
1.
Shut the power off.
2.
From the back of the unit, remove the six screws, then lift the fan
mount plate out.
3. Remove the electrical access panel from the left side of the insert by
removing five screws.
4. Disconnect the green ground wire on the right side of the unit (refer to
wiring diagram).
Green/Vert
Neutral/Neutre
Live/
Sous
tension
Green/Vert
Black/
Noir
Black/
Noir
Red/
Rouge
IFC Board/
Panneau IFC
5. Remove the fan from the mounting plate by removing four screws from
the outside of the fan access panel.
NO
TE
•
To access the side and rear panels, disconnect the gas and venting (see the venting and flue installation sections in this manual for steps). You cannot
access the blower from the front of the appliance.
7.
To install, reverse these steps.
6.
D isconnect the red and black wire from the fan motor and green ground
wire.