  During the first few days it may be more 

difficult to start the fire. As you dry out your 

firebrick and your masonry flue, your draft 

will increase.

10)

 For those units installed at higher elevations 

or into sub-standard masonry fireplaces, 

drafting problems may occur. Consult an 

experienced dealer or mason on methods 

of increasing your draft.

11) 

Some cracking and popping noises may be 

experienced during the heating up process. 

These noises will be minimal when your unit 

reaches temperature.

12)

 Before opening your door to reload, open 

draft fully for approximately 10 to 15 seconds 

until fire has been re-established. This will 

minimize any smoking.

13)

 All fuel burning appliances consume oxygen 

during operation.  It is important that you 

supply a source of fresh air to your unit 

while burning. A slightly opened window is 

sufficient for the purpose.  If you also have 

a fireplace in your home, a downdraft may 

be created by your Regency Stove causing 

a draft down your chimney. If this occurs, 

slightly open a window near your unit.

CAUTION:  If the body of your unit, flue baffle 

or any part of the chimney connector starts 

to glow, you are overfiring.  Stop loading fuel 

immediately and close the draft control until 
the glow has completely subsided.

14) 

Green or wet wood is not recommended for 

your unit.  If you must add wet or green fuel, 

open the draft control fully until all moisture 

has  been  dispersed  by  the  intense  fire.  

Once all moisture has been removed, the 

draft control may be adjusted to maintain 

the fire.

15)

 If you have been burning your stove on a 

low draft, use caution when opening the 

door.  After opening the damper, open the 

door a crack, and allow the fire to adjust 

before fully opening the door.

16)

 The controls of your unit or the air supply 

passages should not be altered to increase 

firing for any reason.

17)

 If you burn the unit too slowly or at too low 

a setting your unit will not be operating as 

efficiently as it can.  An easy rule of thumb 

says that if your glass is clean, then your 

flue  is  clean  and  your  exhaust  is  clean.  

Burn the stove hot enough to keep your 

glass clean and you won't need to clean 

your flue as often.

   

MAINTENANCE

CREOSOTE

When wood is burned slowly, it produces 

tar and other organic vapours, which when 

combined with moisture, form creosote. The 

creosote vapours condense in the relatively 

cool chimney flue of a slow burning fire. As a 

result, creosote residue accumulates on the flue 

lining.  When ignited, this creosote can result 

in an extremely hot fire.

WARNING:  Things to remember in case 

of a chimney fire:

1. Close all draft and damper controls.

2. CALL THE FIRE DEPARTMENT.

Ways to Prevent and Keep Unit 

Free of Creosote

1) 

Burn stove with the draft control wide open 

for about 10-15 minutes every morning 

during burning season.

2) 

Burn stove with draft control wide open for 

about 10 - 15 minutes every time you apply 

fresh wood. This allows the wood to achieve 

the charcoal stage faster and burns up any 

unburned gas vapours which might other-

wise be deposited within the system.

3)  Only burn seasoned wood!

  Avoid burning 

wet or green wood. Seasoned wood has 

been dried at least one year.

4) 

A  small  hot  fire  is  preferable  to  a  large 

smouldering one that can deposit creosote 

within the system.

WOOD STORAGE

Store wood under cover, such as in a shed, or 

covered with a tarp, plastic, tar paper, sheets 

of scrap plywood, etc., as uncovered wood can 

absorb water from rain or snow, delaying the 

seasoning process.

MAINTENANCE

It is very important to carefully maintain your 

fireplace  stove,  including  burning  seasoned 

wood and maintaining a clean stove and chim-

ney system. Have the chimney cleaned before 

the burning season and as necessary during 

the season, as creosote deposits may build up 

rapidly. Moving parts of your stove require no 

lubrication.

 

5) 

The chimney and chimney connector should 

be inspected at least once every two months 

during the heating season to determine is a 

creosote buildup has occured.

6)

 

Have chimney system and unit cleaned 

by competent chimney sweeps twice a 

year during the first year of use and at 

least once a year thereafter or when a 

significant layer of creosote has accu

-

mulated (3 mm/1/8" or more) it should be 

removed to reduce the risk of a chimney 

fire. 

GLASS MAINTENANCE

Your Regency stove is supplied with 5 mm 

Neoceram ceramic glass that will withstand 

the highest heat that your unit will produce.  In 

the event that you break your glass by impact, 

purchase your replacement from an authorized 

Regency dealer only, and follow our step-by-step 

instructions for replacement. 

Allow the stove to cool down before cleaning 

the glass, do not clean the glass when it is hot. 

Do not use abrasive cleaners.

 

Rear View of Door shown

Allen Screw

Latching 

Sleeve

Set

Screw

DOOR LATCH

ADJUSTMENT

The door latch may require adjustment as the 

door gasket material compresses over time.  

Follow  the  steps  below  to  allow  the  latch  to 

be moved closer to the door frame, causing a 

tighter seal;

1)

  Unscrew latching sleeve.

2)

  Remove allen screw.

3)

  Spin door handle clockwise to desired depth.

4)

  Re-install allen screw and latching sleeve.

5)

  Adjust set screw to proper depth to ensure  

       that the handle does not rotate 360 degrees.

Содержание F150B-1

Страница 1: ...or assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicin...

Страница 2: ...wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictio...

Страница 3: ...oor Latch Adjustment 9 Wood Storage 9 PARTS LIST Stove Assembly 10 WARRANTY Warranty 11 Data Badge 4 Unit Dimensions 5 Heat Shield Position 5 INSTALLATION Residential Installation 6 Safety Guidelines...

Страница 4: ...t accompanies each F150B 1 Freestanding Wood Fire We have printed a copy of the contents here for your review COMPLIANCE PLATE NOTE Regency units are constantly being improved Check the label on the u...

Страница 5: ...HEAT SHIELD POSITION The heat shield must be raised if the stove is installed where the rear wall is combustible Remove the heat shield by undoing the 4 bolts Move the heat shield up to align the bot...

Страница 6: ...oke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverfiring Stopaddingfueland close the draft control...

Страница 7: ...nstaller in accordance with AS NZS 2918 2001 Flo Met Super Single 1 Hawkwind Standard 2 AHD Special Insulated 3 IMPORTANT 1 The Flo Met Super Single flue kit must be installed with a 130o x 900mm stai...

Страница 8: ...ports at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire...

Страница 9: ...in an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove w...

Страница 10: ...8 8010102 Ash Lip Panel 8010101 Top Panel 10 8010110 Door Assembly without Handle 11 8010114 Door Handle Set 12 8010106 Neoceram Glass w Gasket 13 8010107 Air Slide 8010611 Steel baffle optional A 75...

Страница 11: ...is the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products...

Страница 12: ...____________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to regi...

Отзывы: