30
Regency
®
E18 Gas Fireplace Insert
INSTALLATION
E18 INSTALL SPECIFICATIONS
See Installation of E18 into Existing Units for General Installation Guidance.
This install of the E18 uses
Vent Connection Type A.
The Length of 4" Flex needed is 3" semi-expanded. Secure fl ue adapter top plate to under side of existing fi rebox using 4 self taping
screws.
PP
%
65)LUHER[
(,QVHUW
'(7$,/%
6&$/(
$GDSWRU3ODWH
IDVWHQHUVHWWLQJ
PP
/HJ6HWWLQJ2XWHU6KHOO3RVLWLRQ
)OH[$GDSWRU/HQJWK
&ROODU3ODWH6HWWLQJ9HQWSRVLWLRQ
PP
PP
PP
$
65)LUHER[
/HJK
Right side shown
Set to this
hole
1
. Loosen 2 x philips screws on both right and left legs.
2
. See above diagram below for required leg setting.
3.
Install with supplied phillips screws to prepunched holes and tighten previous screws that were loosened in Step 1.
4
. Keep left side leg loose until outer fi rebox is in position in ZC box - to allow adjustment of gas line.
Set to this
hole
Secure top plate to fi rebox w/4 screws.
Secure vent slide plate to fl ex pipe with 4
screws