Regency I2450M
|
15
15
|
installation
Floor Protection
Please check to ensure that your floor protection
and hearth will meet the standards for clearance to
combustibles. Your hearth extension must be made
from a non-combustible material.
Flue Baffle &
Secondary Air Tube
Installation
The flue baffle system located in the upper area
of the firebox is removable to make cleaning your
chimney system easier. The baffles must be
installed prior to your first fire.
Smoke spillage
and draft problems may occur if the baffles
are improperly positioned.
Check the position
of the baffles on a regular basis as they can be
dislodged if too much fuel is forced into the firebox.
The unit arrives with the 2 baffles and 2 air tubes
on the floor of the firebox.
1. Open the door and remove stainless steel
smoke deflector - See smoke deflector instruc-
tions in this manual.
Smoke
Deflector
2. Slide the left baffle over the 2 remaining air
tubes from the front and then push it to the
back.
Side View
4 . Install the 2 front secondary air tubes with pliers
and hammer to lock them into place, as shown
below.
3.
Tilt the left baffle up on top of the side chan-
nel and it will leave enough room to position
the right baffle in the same manner as Step
1) above. Then reposition the left baffle flat on
the air tubes.
Important:
Push both baffles so they are tight
against the side walls.
Front View
Front View
5. Reverse Step 1.
Glass Replacement
Your Regency stove is supplied with 5 mm Ne-
oceram ceramic glass that will withstand the highest
heat that your unit will produce. In the event that
you break your glass by impact, purchase your re-
placement from an authorized Regency dealer only.
Remove the door from the stove and remove the
screws securing the glass retainer. Position the glass
in the door, make sure that the glass gasketing will
properly seal your unit, and replace the retainer,
it should rest on the gasket not the glass. Tighten
securely, but do not wrench down on the glass as
this may cause the glass to break.
Shown with Classic Door