background image

4

    | 

F2450M Regency Freestanding Woodstove

safety decal

This is a copy of the label that accompanies each 
Regency  Freestanding Woodstove  (F2450M). 
We have printed a copy of the contents here 
for your review.

NOTE:

  Regency  units  are  constantly  being 

improved.  Check  the  label  on  the  unit  and  if 
there is a difference, the label on the unit is the 
correct one.

Part #: 920-037a

Size:   6.53" H x 10.8" W (File at 100%) 

Color: black on grey except for the items indicated as being printed in red.

Mar. 16/17: Created decal

June 06/18: Updated decal

July16/18: Updated decal w/EPA info

July 19/18: Updated decal

Nov.22/18: Updated Floor protection dim.

Mar 06/19: Updated clea standards

Oct 07/19: Updated to mobile homes in Canada and the United States

duplicate serial number

MINIMUM ALCOVE CEILING HEIGHT: 2109 MM / 83"         MAXIMUM ALCOVE DEPTH 1219 MM / 48".    
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 405 MM / 16"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.

C

B

D

A

FOR USE WITH SOLID WOOD FUEL ONLY.  USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.  DO NOT OBSTRUCT COMBUSTION AIR OPENINGS.  OPERATE ONLY WITH 
FIREBRICKS IN PLACE.  RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY CLOSED. IF INSTALLED IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR 
TO FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING.  INSPECT 
AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY.  UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY.  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY 
FROM HEATER.  REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND 
SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN PART #075-917, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT 
IN CANADA: LISTED ULCS 629 CHIMNEY. USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION/INSTRUCTIONS
IN USA:  LISTED UL 103 HT CHIMNEY 

HAUTEUR MINIMALE DU PLAFOND DE L’ALCÔVE : 2109 MM / 83 PO PROFONDEUR MAXIMALE DE L’ALCÔVE : 1219 MM / 48 PO
DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 405 MM / 16 PO.
L’ESPACE SOUS LE POÊLE NE DOIT PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES EN PLACE.
À UTILISER AVEC DU BOIS SOLIDE SEULEMENT. L’UTILISATION D’AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE POÊLE ET CRÉER UNE CONDITION DANGEREUSE. NE PAS OBSTRUER LES OUVERTURES 
D’AIR DE COMBUSTION. UTILISER SEULEMENT AVEC LA PORTE FERMÉE – OUVRIR SEULEMENT LA PORTE DE CHARGEMENT POUR ALIMENTER LE FEU. NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER 
LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L’ÂTRE. NE PAS SURCHAUFFER – SI LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, RISQUE DE SURCHAUFFAGE. INSPECTER 
ET NETTOYER FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUR. DANS CERTAINES CONDITIONS D’UTILISATION, UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. GARDER LES MEUBLES ET 
AUTRES MATÉRIAUX COMBUSTIBLES ÉLOIGNÉS DU POÊLE. REMPLACER LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON 
COMBUSTIBLES DÉPASSANT SUR LE DESSOUS, LE DEVANT ET LES CÔTÉS DU POÊLE, TEL QU’INDIQUÉ, OU JUSQU’AU MATÉRIAU COMBUSTIBLE LE PLUS PRÈS PERMIS.
COMPOSANTS EN OPTION : VENTILATEUR PIÈCE N

o

075-917, ALIMENTATION ÉLECTRIQUE : 115 VOLTS, 60 HZ, 2 AMP.

DANGER : RISQUE D’ÉLECTROCUTION. DÉCONNECTER L’ALIMENTATION ÉLECTRIQUE AVANT D'EFFECTUER L’ENTRETIEN DU POÊLE. NE PAS INSTALLER LE CORDON ÉLECTRIQUE SOUS OU DEVANT L’APPAREIL.
COMPOSANTS EXIGÉS POUR INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D’AIR EXTÉRIEUR.
AU CANADA :  CHEMINÉE HOMOLOGUÉE ULCS 629. UTILISER LES PIÈCES DE LA CHEMINÉE TEL QUE SPÉCIFIÉ DANS LES CONSIGNES D’INSTALLATION.
AUX ÉTATS-UNIS : CHEMINÉE HOMOLOGUÉE UL103HT.

512

 CAUTION 

HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

ATTENTION

CHAUD DURANT LE FONCTIONNEMENT. NE TOUCHEZ PAS. 

ÉLOIGNEZ LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES. 

LE CONTACT PEUT CAUSER DES BRÛLURES.

LISEZ LA PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS

MADE IN CANADA / FABRIQUÉ AU CANADA

MANUFACTURED BY/ FABRIQUÉ PAR :
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC  V4G 1H4

LISTED SPACE HEATER, SOLID FUEL TYPE,  ALSO 

SUITABLE FOR MOBILE HOME INSTALLATION /  

APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGUÉ 

À COMBUSTIBLE SOLIDE, CONVENANT AUSSI

POUR INSTALLATION DANS UNE MAISON MOBILE 

FLOOR PROTECTION*

PROTECTION DE PLANCHER*

* Au Canada, la protection de plancher doit dépasser de 18 po (457 mm) 
à l’avant (16 po aux États-Unis) et de 8 po (200 mm) de chaque côté du 
poêle et derrière le poêle.

* In Canada, floor protection must extend 18" (457mm) to the front (16" 

for USA) and 8" (203mm) to each side and back of the stove.

DO NOT REMOVE THIS LABEL/

 NE RETIREZ PAS CETTE ÉTIQUETTE

512

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.  CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS 
AND INSTALLATION INSPECTION IN YOUR AREA.  USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT FACTORY-BUILT 
CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.  
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.  DO NOT PASS 
CHIMNEY CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
INSTALLER ET UTILISER SEULEMENT SELON LES CONSIGNES D’INSTALLATION ET D’UTILISATION DU FABRICANT. CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-
INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE LES RESTRICTIONS ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION. UTILISER UN CONNECTEUR D’UN DIAMÈTRE MINIMAL DE 150 
MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFA-BRIQUÉE HOMOLOGUÉE UL103 HT CONÇUE POUR ÊTRE UTILISÉE AVEC DES COMBUSTIBLES 
SOLIDES OU UNE CHEMINÉE EN MAÇONNERIE.
VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS  D'INSTALLATION  D'UNE CHEMINÉE TRAVERSANT UN MUR OU UN PLAFOND 
EN MATÉRIAUX COMBUSTIBLES. NE PAS FAIRE TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES. NE PAS RACCORDER CE POÊLE 
À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.

920-037a

MODEL:  

REGENCY  MEDIUM  FREESTANDING STOVE -  F2450M

TESTED TO:  ULC S627-00 / UL 1482-2011 (R2015)    

A  1245 mm / 49 in (Canada)

A     1194mm / 47 in (USA)

B  457 mm / 18 in

B  406 mm / 16 in 

C  856 mm / 33-11/16 in

D     203 mm / 8 in

 JAN    FEB    MAR     

APR     MA

Y   JUN     JUL

    

AUG    SEPT   OCT   NOV     DEC

DA

TE OF MANUF

ACTURE

2021

2023

2024

2025

2022

0219WS026S

WARNING: ONLY USE LISTED REGENCY OPTIONS SUCH AS LEGS, AIRMATE, FAN AS SHOWN IN THE INSTALLATION MANUAL.
CAUTION: BURNING OF MATERIALS OTHER THAN SPECIFIED MAY CAUSE DAMAGE TO THE UNIT.
CAUTION: MOVING PARTS MAY CAUSE INJURY.

U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission standards using cord wood.”  Tested to ASTM E3053.  Model Regency 
F2450M – 2.3g /hr. This wood heater needs periodic inspection and repair for proper operation. Consult the owner's manual for further information. It is against federal regu-
lations to operate this wood heater in a manner inconsistent with the operating instructions in the owner's manual.
Certifié conforme aux normes 2020 du U.S. ENVIRONMENTAL PROTECTION AGENCY en matière d'émission de particules de bois en utilisant le bois de corde. Approuvé 
ASTM E3053. Modèle Regency F2450M – 2,3 g /h. Cet appareil de chauffage au bois doit être inspecté périodiquement et réparé pour fonctionner correctement. Consulter 
le manuel d’installation pour plus d’information. La réglementation fédérale interdit de faire fonctionner un tel appareil si les consignes d'utilisation contenues dans le présent 
manuel ne sont pas respectées.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

DÉGAGEMENTS MINIMAUX PAR RAPPORT AUX MATÉRIAUX COMBUSTIBLES

F2450M WITH AIRMATE SHIELD

F2450M  WITH REAR DEFLECTOR

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

MEASURE   

  

  

       FLUE

FROM  

          HEATER           CENTER-LINE

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

SIDEWALL 

A  406  mm / 16 in    

D  711 mm / 28 in

BACKWALL 

B  292  mm / 11.5 in 

E  457 mm / 18 in

CORNER 

C  203  mm /  8 in   

F  508 mm / 20 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL 

A  381 mm / 15 in  

D  686 mm / 27 in

BACKWALL 

B  254 mm / 10 in  

E  419 mm / 16.5 in

CORNER 

C  152 mm / 6 in   F  457 mm / 18 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL 

A  381 mm / 15 in  

D  686 mm / 27 in

BACKWALL 

B  254 mm / 10 in  

E  419 mm / 16.5 in

CORNER 

C  152 mm / 6 in   F  457 mm / 18 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

SIDEWALL 

A  406  mm / 16 in  

D  711  mm / 28 in

BACKWALL 

B  241  mm / 9.5 in     E  406  mm / 16 in

CORNER 

C  203  mm / 8 in  

F  508  mm / 20 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME 

SIDEWALL 

A  381  mm / 15 in  

D 686 mm / 27 in

BACKWALL 

B  203  mm / 8 in  

E 368 mm / 14.5 in

CORNER 

C  152  mm / 6 in  

F 457 mm / 18 in 

SIDEWALL 

A  381 mm / 15 in  

D  686 mm / 27 in

BACKWALL 

B  203  mm / 8 in  

E  368 mm / 14.5 in

CORNER 

C  152  mm / 6 in  

F  457 mm / 18 in

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR - ALCOVE

SIDEWALL 

G  380 mm / 15 in  

I  686 mm / 27 in

BACKWALL 

H  254 mm / 10 in  

J  419 mm / 16.5 in

MEASURE   

  

  

       FLUE

FROM  

        HEATER          CENTER-LINE

SIDEWALL 

G  380 mm / 15 in  

I  686 mm / 27 in

BACKWALL 

H  203 mm / 8 in   J  368 mm / 14.5 in

This appliance is approved for mobile home installations in Canada and the USA.

Cet appareil est homologué pour être installé dans une maison mobile au Canada et aux États-Unis.

AVERTISSEMENT : UTILISER SEULEMENT LES OPTIONS HOMOLOGUÉES PAR REGENCY COMME LES PATTES, LE DIFFUSEUR AIRMATE, LE VENTILATEUR COMME ILLUTRÉ DANE LE MANUEL D'INSTALLATION.
ATTENTION : 

 

COMBUSTION DE  TOUT MATÉRIAU NON SPÉCIFIÉ PEUT ENDOMMAGER L'APPAREIL.

ATTENTION : LE DÉPLACEMENT DES PIÈCES PEUT ENTRAÎNER DES BLESSURES.

 

COMBUSTION DE  TOUT MATÉRIAU NON SPÉCIFIÉ PEUT ENDOMMAGER L'APPAREIL.

Содержание Classic F2450M

Страница 1: ...ding Woodstove F2450M 04 21 21 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference Owners Installation Manual Tested by www regency fire com French Manual Download https bit ly 3rAsDW7 Manuel en Français https bit ly 3rAsDW7 ...

Страница 2: ...peration It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURNUNTREATEDWOODONLY OTHERMATERIALSSUCHASWOODPRESERVATIVES METALFOILS COAL PLASTIC GARBAGE SULPHUR OR OIL MAY DAMAGE THE STOVE This heater is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dr...

Страница 3: ...Installing Outside Air Using Bottom Heat Shield Legs 17 Recommended Heights For Woodstove Flue 18 Optional Outside Air Kit 19 Brick Installation 20 Wood Handle Door Assembly 21 Flue Baffle Secondary Air Tube Installation 22 Fan Installation 23 Stainless Steel Smoke Deflector Installation 24 Operation Seasoned Firewood 25 Operating Instructions 25 Draft Control 25 First Fire 26 Fan Operation 27 Ash...

Страница 4: ...de and back of the stove DO NOT REMOVE THIS LABEL NE RETIREZ PAS CETTE ÉTIQUETTE 512 INSTALLANDUSEONLYINACCORDANCEWITHTHEMANUFACTURER SINSTALLATIONANDOPERATINGINSTRUCTIONS CONTACTLOCALBUILDINGORFIREOFFICIALSABOUTRESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA USE 150 MM 6 IN DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT FACTORY BUILT CHIMNEY SUITABLE FOR ...

Страница 5: ... 3 16 817mm 34 5 8 879mm 27 1 8 690mm 24 13 16 630mm 6 7 16 163mm 33 7 8 860mm 31 7 16 798mm 7 13 16 198mm 21 1 4 540mm 21 1 2 546mm 23 1 8 587mm from fuel door opening Rear Front Rear 4 9 16 115mm 6 13 16 173mm Images for OUTSIDE AIR DIMENSIONS Rear Front 4 9 16 115mm Images for OUTSIDE AIR DIMENSIONS ...

Страница 6: ...y the chimney connector must be at least 24 gauge steel Do not use galvanized pipe For Mobile Home installation refertotheMobileHomeinstallationinstructions within this manual 12 DO NOT CONNECT THIS UNIT TO A CHIM NEY SERVING ANOTHER APPLIANCE 13 A chimney connector cannot pass through an attic or roof space closet or similar concealed space or a floor ceiling wall or partition of combustible cons...

Страница 7: ...ar heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for ship ping and handling It allows for a handhold on the top of the stove Before placing the stove in its final position the side shields must be raised Loosen the screws on the rear on the stove 3 per side slide the side panel up as far as possib...

Страница 8: ... the legs to the stove if the stove is tipped on its back preferably on a soft surface to prevent scratching Ensure to be extremely careful when tipping stove Important Prior to installing the bottom heat shield remove the 4 inch blanking plate See below This must be removed for combustion air to enter the ap pliance 1 Removethe4boltsfromundersideofthebaseofthepedestal and discard Also remove cove...

Страница 9: ... air A F F C C B E D NOTE Be aware that local Codes and Regulations may override some clearances listed in this manual Check with your local inspector NOTE This clearance is also required for air space between the appliance and wall ceiling Residential Installation C Vent Single Wall Unit From Unit From Corner From Flue Center Line A B C D E F Medium F2450M with Airmate 16 406mm 9 5 241mm 8 203mm ...

Страница 10: ...16 856mm 8 203mm Residential Close Clearance To be installed with required pipe components Unit A B C D F2450M with Airmate Canada 48 1219mm 18 457mm 33 11 16 856mm 8 203mm USA 46 1168mm 16 406mm 33 11 16 856mm 8 203mm F2450M with Rear Deflector Canada 50 1270mm 18 457mm 33 11 16 856mm 8 203mm USA 48 1219mm 16 406mm 33 11 16 856mm 8 203mm C B D A D Minimum Alcove Clearance and Clearance to Combust...

Страница 11: ...llation A combustible floor must be protected by non combustible material like tile concrete board or certified to UL 1618 or as defined by local codes extending beneath the heater and a minimum of 8 203mm from each side and minimum 16 406mm from the front face of the stove and minimum 6 152mm or the rear clearance to combustibles whichever is smaller from the rear of the stove Wheninstalledwithho...

Страница 12: ...try with the minimum required height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof with roofing compound Secure the flashing to your roof with nails or screws 5 Place the storm collar over the flashing sealing the joints with a silicone caulking 6 Fasten the raincap with spark screens if required to...

Страница 13: ...alled and operated When connect ing the stove through a combustible wall to a masonrychimney specialmethodsareneeded Ensure that an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure Masonry Fireplace There are listed kits available to connect a stove to a masonry fireplace The kit is an adapter that is installed at the locatio...

Страница 14: ...combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separatio...

Страница 15: ...f exit for a height up to 7ft 2130mm 6 Thechimneyshallbeattacheddirectlytotheroom heater and shall extend at least 3 ft 914mm above the part of the roof through which it passes The top of the chimney should project at least 2ft 610mm above the highest elevation of any part of the Mobile Home within 10 ft 3048mm of the chimney 7 The chimney system shall comply with Local Requirements 8 Any openings...

Страница 16: ...ecure flex to the Mobile Home box 7 Secure pedestal base and Mobile Home Box to firebox as shown in diagram 3 using the screws that were previously removed loosened in step 1 See pedestal instructions The Mobile Home Box and firebox use the same screws Diagram 4 8 Install blanking plate to the front of the pedestal with 4 screws 1 Lay unit on its back Remove two front 7 16 bolts Loosen rear two 7 ...

Страница 17: ...l with 4 screws Use picture from step 8 16 Install the mandatory outside air kit See Mobile Home Instal lation section in this manual Place unit into its final position to complete install Installing Outside Air Using Bottom Heat Shield Legs Page 1 of 1 075 500 SLDASM 12 19 2016 Mobile Home Box Square Transition Box Collar Bottom Heat Shield Cast legs Knock out Blanking plate 17 Remove knock out f...

Страница 18: ...0 0 18 0 22 5 4000 5000 14 0 15 0 16 0 17 5 21 0 18 5 23 0 5000 6000 14 5 15 5 17 0 18 0 21 5 19 0 24 0 6000 7000 15 0 16 0 17 5 18 5 22 5 20 0 25 0 7000 8000 15 5 16 5 18 0 19 0 23 0 20 5 25 5 8000 9000 16 0 17 0 18 5 20 0 24 0 21 0 26 5 9000 10000 16 5 17 5 19 0 20 5 24 5 22 0 27 0 NOTE No more than two offsets four elbows allowed Two 45o elbows equal one 90o elbow WARNING DO NOT INSTALL IN SLEE...

Страница 19: ...e fresh air into the pedestal area by using a minimum 4 duct pipe with a mesh grill at the outside termination Outside Air Through Pedestal Rear Remove the blanking plate from the rear of the pedestal and bend the two tabs out 90 degrees Pipe fresh air into the pedestal area by using a minimum 4 metallic duct pipe with a mesh grill at the outside termination Fasten the pipe to the cover plate usin...

Страница 20: ...n their correct positions Do not use a grate NOTE The AD brick in the drawings above is the brick covering the Ash Dump hole that is used when the Ash Drawer Kit is installed refer to the Listed Components for Mobile Home Installation section LyTherm sheet Order of firebrick install a Rear Firebrick b Firebox floor install brick over LyTherm Sheet c Right and left side Firebricks 70 AD 70 70 70 74...

Страница 21: ...oor is not creating a tight seal a washer can be removed Recheck door to ensure there is still a tight seal Repeat steps if door seal is still not tight until a tight seal has been achieved The handle should be approximately in the 8 o clock position when door is fully closed Diagram 3 2 Place the door onto the hinges and then place the door handle through the opening on the door as shown in Diagr...

Страница 22: ...2 air tubes on the floor of the firebox 1 Open the door and remove stainless steel smoke deflector See smoke deflector instructions in this manual 2 Remove the front secondary air tube with pliers as shown below 4 Install the 2 front secondary air tubes with pliers and hammer to lock them into place as shown below 3 Tilt the left baffle up on top of the side channel and it will leave enough room t...

Страница 23: ...usly the thermo switch sensor is not making contact with the stove body Remove the fan bend the bracket closer to the stove and re install the fan MANUAL To manually operate the fan system push the bottom switch to MAN and the top switch to either HIGH or LOW This will bypass the sensing device and allow full control of the fan Switching from AUTO to MAN or HIGH to LOW may be done anytime CAUTION ...

Страница 24: ...sen off both bolts and slide defector upward and out Install new deflector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through t...

Страница 25: ...on of dryness but may not be a reliable indicator Some wet wood has checks and some dry wood has no checks The wood tends to darken from white or cream colour to grey or yellow as it dries Two dry pieces banged together sound hollow wet pieces sound solid and dull Dry wood weighs much less than wet wood Split a piece of wood If the exposed surface feels damp the wood is too wet to burn Seasoned Fi...

Страница 26: ...aintbecomesseasoned Windows and or doors should be left open to provide adequate ventilation while this tem porary condition exists Burning the stove at a very high temperature the first few times may damagethepaint Burnfiresatamoderatelevel the first few days 6 Do not place anything on the stove top during the curing process This may result in damage to your paint finish 7 During the first few da...

Страница 27: ...ild up in the chimney system Check and clean chimney at regular intervals Failure to do so can result in a serious chimney fire 8 YourRegencystovecanbeveryhot Youmaybe seriously burned if you touch the stove while it is operating keep children clothing and furniture away Warn children of the burn hazard 9 Thestoveconsumesairwhileoperating provide adequate ventilation with an air duct or open a win...

Страница 28: ...Salt drift wood Cut lumber plywood mill ends Kiln dried wood Classic Door Handle Replacement Glass Replacement Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Remove the door from the stove and remove the ...

Страница 29: ...am ceramicglass Part 846 306 thatwillwithstandthe highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only and follow our step by step instructions for replacement refer to Glass Replacement section Allow the stove to cool down before cleaning the glass Cleaning the glass will prevent build up of carb...

Страница 30: ...Replace any damaged parts Adjust door catch assembly If unable to obtain a tight seal on the door replace door gasket seal Readjust door catch after new gasket installed Inspect condition and seal of Glass Gasket Door Gasket Perform paper test replace gasket if required Paper Test Test the seal on the loading door with a paper bill Place a paper bill in the gasket area of the door on a cold stove ...

Страница 31: ...air tubes vermiculite baffles as per page 22 2 Loosen the two 7 16 bolts nuts to remove replace vertical deflector 3 Repeat steps to install new vertical deflector NOTE ENSURE THAT VERTICAL DEFLECTOR IS PUSHED UP AS FAR AS POSSIBLE TIGHT TO TOP OF FIREBOX Vertical Deflector Remove 2 front air tubes Slide left down to remove Reverse to replace ...

Страница 32: ... 8 Window Adhesive Sold per foot 4 Feet required 14 075 077F Glass Retainer 15 021 973 Door Handle Assembly Complete 16 948 079BN Hinge Cap Brush Nickel Each 17 948 146 Long Black Handle 18 850 241 Black Door Complete 18 850 243 Black with Nickel Accent Door Complete 19 846 515 Fan Assembly Complete 20 910 138 2 Way Switch 21 910 140 3 way Switch 22 850 105 Airmate 23 075 051 SS Slide Holder 8 075...

Страница 33: ...F2450M Regency Freestanding Woodstove 33 parts list 7 8 22 3 6 4 2 18 13 1 14 17 12 11 16 19 20 21 ...

Страница 34: ...eat Shield 43 942 110 Ashplug 44 820 249 Ashplug Tool 45 021 024 Blanking Plate N S 904 100 5 16 x 5 1 2 Long Hex Head Bolt Each N S 820 468F Metal Washer N S 820 456 Metal Spacer Support Bracket Each 45 44 42 43 41 40 51 52 50 53 Part Description 50 021 915 Pedestal Complete 51 075 069 Pedestal Door 52 904 257 Magnetic Catch Each 53 075 910 Ashdrawer N S 904 023 5 16 x 1 1 2 Hex Head Bolt Each Ba...

Страница 35: ...D 70 70 70 74 72 72 76 020 960 Brick Kit Complete 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 72 Brick Partial 1 1 4 x 2 x 4 1 2 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 76 Brick Partial 1 1 4 x 2 x 9 NOTE This kit contains one spare brick in case of breakage ...

Страница 36: ...razing 1 Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at ...

Страница 37: ...incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs kiln dried wood lack of regular ma...

Страница 38: ...idental or consequential damages so the above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain all warranty and service In the event the authorized ...

Страница 39: ...n order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases mad...

Страница 40: ...40 F2450M Regency Freestanding Woodstove warranty ...

Страница 41: ...F2450M Regency Freestanding Woodstove 41 notes ...

Страница 42: ...42 F2450M Regency Freestanding Woodstove notes ...

Страница 43: ...F2450M Regency Freestanding Woodstove 43 dimensions ...

Страница 44: ...omplete the following information Dealer Name Address ____________________________________ ________________________________________________________ Installer _________________________________________________ Phone _________________________________________________ Date Installed ____________________________________________ Serial __________________________________________________ ...

Отзывы: